Ducted heatpumps are a thing here in NZ and make sense to me, not that I have used one. The heatpump sits in the roof and air is pushed into three or so rooms through ducts.
If building a new house I think ducts would be the way to go.
Most roofs in Australia still aren’t sealed. The air barrier and insulation barrier is the ceiling. The roof space itself is not insulated, so the ducts are exposed to extreme temperatures, thus destroying the efficiency.
Here is just one article on it: https://newenergythinking.com/2018/10/20/dont-use-ducts/
My argument with split systems, at least how they are installed in NZ, is that they are usually installed in the main living area and if there is a second unit, in a corridor.
So corridors are heated or cooled far hotter or colder than they need to be in order to heat/cool bedrooms.
One has mini splits. You definitely don’t generally put mini splits in every single room (like bathrooms or interior hallways) because each mini split requires tubing, is large, and expensive. No, I think it’s way more likely that you would have them in the bedrooms rather than the hallway
But we have many very toasty hallways leading to cold single glazed bedrooms!
In the last few years the central govt has brought in legislation requiring landlords to heat and insulate homes to a certain standard.
They also recently undid a long held myth about ducts buried in insulation leading to condensation issues. Most areas now allow ducts to be buried as long as you have R19 above and below, or R30 above. When I just installed a ducted mini for 3 upstairs bedrooms, I surrounded my R8 flex duct with R30 insulation.
Like you said, it’s physics.
We have a two-level, five bedroom new build in Auckland which came with a single-zone ducted system. So outputs are the bedrooms plus upstairs and downstairs lounges. The vents are tidy and unobtrusive - much less space than a wall unit in each location.
We're having major issues balancing the temperature across the different rooms as there is one thermostat.
Think setting the temperature overnight for one room with a couple plus a cat vs another room with one of the kids. Basically the wife and I are always far too hot because otherwise we're freezing all the other rooms. Or setting a reasonable temperature in the lounge makes all the rooms icy in short time.
I'm now thinking about forking out the couple of thousand to get a small heat pump installed directly into our room so we can run it separately from the rest of the house.
So if building from scratch, either look into a multi-zone system or separate heatpumps. If you can get separate systems but hidden in the walls/roof that would be the best.
I have the fan programmed to run 10 or 15 minutes an hour regardless of if the heat pump needs to run. It keeps things pretty even.
https://www.amazon.com/AC-Infinity-Register-Thermostat-Contr...
Appropriately placed In-line duct fans and register fans will pull the heated/cooled air where you want.
The stat is that you lose between 25-40% efficiency for "typical" existing installations. The document goes on to explain that an insulated duct which doesn't leak doesn't have this kind of efficiency loss.
[1] https://www.google.com/url?q=https://www1.eere.energy.gov/bu...
Ducts are still needed to circulate air, especially if you want to remove stale air (e.g., bathrooms, kitchen) and bring in (filtered) fresh air (to bedrooms).
I have a CO2 detector that I believe is a reasonable proxy for stale air. When it goes above 1000 I simply open the windows. By the time I remember to close the windows the reading is almost always below 500.
That seemed like the easiest thing to do without making much more complicated system. Basically risk 1hour of bad air for 23h of "clean" air.
A great option for keeping CO2 levels down in a house is with an HRV (or ERV) [1] that will heat the fresh air coming in to cycle it throughout the house.
I did not 3D print mine, but ordered it, though as an early adopter, adjustment was required.
> During the warmer seasons, an ERV system pre-cools and dehumidifies; During cooler seasons the system humidifies and pre-heats.[1] An ERV system helps HVAC design meet ventilation and energy standards (e.g., ASHRAE), improves indoor air quality and reduces total HVAC equipment capacity, thereby reducing energy consumption.
> ERV systems enable an HVAC system to maintain a 40-50% indoor relative humidity, essentially in all conditions. ERV's must use power for a blower to overcome the pressure drop in the system, hence incurring a slight energy demand.
In Jan 2023, the ERV wikipedia article has a 'Table of Energy recovery devices by Types of transfer supported': Total and Sensible :
> [ Total & Sensible transfer: Rotary enthalpy wheel, Fixed Plate ]
> [ Sensible transfer only: Heat pipe, Run around coil, Thermosiphon, Twin Towers ]
Latent heat: https://en.wikipedia.org/wiki/Latent_heat :
> In contrast to latent heat, sensible heat is energy transferred as heat, with a resultant temperature change in a body.
Sensible heat: https://en.wikipedia.org/wiki/Sensible_heat
There's a broader Category:Energy_recovery page which includes heat pumps and thus mini-splits: https://en.wikipedia.org/wiki/Category:Energy_recovery
I was respond to a comment that presupposes the need for fresh air. If you don't need that, feel free to close the windows then.
Following the thread of conversation, it just didn't compute to me:
>>>> Heat pumps are great for climate control >>> Yeah, ducts are dead >> What if you want to recirculate air in your house through your central air filter to eliminate smells? > Just open the window
It's like we've hit a contraction: the premise is that we care about energy but the contractions is then that we don't and we open the window while climate controlling the house. So to me it does seem to prove that in some climates, duct work with a central blower and filter mat not be dead.
Ducts running in an insulated space are sources of huge energy loss.
We've just today had our first snow of the season here in a lower elevation of the Sierra Foothills. It's been chilly for 3 months or so, and our heating is an 'old school' ducted propane furnace. In time, we'll replace it with a heat pump, but not this year. Anyway, we're sensitive to accumulated odors that go with a well insulated, closed-up home in winter.
Every evening, we open three doors in the house to the outside. This is after the furnace has entered its timed 'off for the night' state. We exchange pretty much all of our air for fresh ambient, which is great when we wake up in the morning.
The impact from doing this on our propane bill is undetectable. This is because air, even humid air, has a trivial heat capacity compared to the warm house structure and contents. Those are by far the greatest energy reservoir in our home. Very little energy is lost in a daily air exchange with the ambient.
*edited for typo
I live in Florida, we've used Heat Pumps for as long as I can remember. We also have central air handlers with blowers and ducts to distribute the conditioned air. Mini-splits can _also_ be ducted mini-splits. According to my HVAC geek friend, mini-splits are pretty terrible about humidity control (an important thing in Florida). For proper humidity control you'd ideally have a dedicated set of dehumidification ducts (powered by a central dehumidifier) as well. Mix in an ERV and you have the ability to build a fairly air-tight house with _controlled_ ventilation and very efficient conditioning of the air in the house.
I was going to install an ERV system but the payback was not within the life of the equipment.
Someday I’ll build a Passivhaus with a system as you describe.
This morning it was -5C, so not cold by continental standards, but certainly cold enough.
In the UK recirculating air is very rare. In cases that bathrooms don't have a window (or indeed in new houses where they do) there's an extractor fan, but that just vents the air directly outside.
The only requirement is "2 channel low drift NDIR gas sensor". Cheap CO2 detectors either have zero IR sensors (instead they guesstimate eCO2 using a VOC sensor) or a single IR sensor that requires weekly calibration outdoors or it will just assume that the lowest sensor reading means 400ppm.
https://www.buildwithrise.com/stories/ductless-heat-recovery
But I want to know if there is a way uneven spots could cause a problem without some effect tanking the average. What do uneven spots themselves do?
[edit: add link]
[0] https://www.energyvanguard.com/blog/Flat-or-Lumpy-How-Would-...
No, you can go to ducts by installing them. I believe the comment is advising against doing so.
>A recirculating central heating system doesn't do that.
They definitely circulate air, and they definitely filter the air. Whether there is fresh air depends, mostly no.
Another option is to supplement an existing ducted system with a ductless one adding additional zones where you might want conditioning over night. E.g. bedrooms where you want to sleep in cold A/C in the summer where the rest of the house can warm up a bit, or a person in the household who likes their room to be warmer than everyone elses in the winter.
ERV/HRV has its place it less moderate climates where there is significant efficiency loss from pulling in outdoor air, especially if indoor conditions require a significant amount of fresh air turnover. But a central HVAC system with a recirculation fan most definitely can be beneficial in a lot of cases.
It's really a very good proposition. Has all of the advantages of central heating and the efficiencies the heat pumps
How do you move the heated/cooled air into/around the house without ducts?
A mini-split system puts an ugly, cheap, plastic wall-cyst within your field of view in every room they’re installed.
Nah.
There have been minisplits in the US for years, they are just not very common. Moreover they have been commonplace in Asia for decades now. They are noticeable. I personally think they look like ass. They are huge and you are blind if you don't notice them. There is a reason why ducted or recessed models are available internationally for luxury homes. It has nothing to do with Americans.
Ducts are a superior look and experience IMO, just slightly less efficient. Nothing wrong with preferring them.
So people COMMONLY wind up with unbalanced floors, and people typically try to fix it by adjusting the vent register opening with mixed success.
Part of the problem is that the thermostat is biased to wherever it is located. You can get systems with remote add-on temperature sensors, but that doesn't by itself adjust where heat/cold is being sent through a ducted system.
The great thing about a Mini-Split is that you're, at minimum, heating each floor independently with its own thermostat. You can then put in e.g. interior door vents that simply let air pass between common areas and the rooms when the doors are closed.
This can go even further with for example two Air Handlers per floor (quad units) on the east and west. So that as the sun moves, the correct level of adjustment can be applied to only the side of the floor that needs it.
One of the biggest pros (in addition to the improved efficiency of a heat pump) is I heat and cool less space than i did before because i can target individual rooms. When i'm in my office all day I only need to heat my office. When it's hot and I'm struggling to sleep only cool my bedroom. There's no point in heating my living room^^ at 08:30 in the morning if i don't intend to spend time in there till 17:00.
Sure, when it gets to 17:00 my living area might not be comfortable, but that can easily be overcome by turning it on half an hour or so beforehand (either manually or with a timer).
^^ I don't live somewhere where freezing pipes are a concern. But i'd imagine you could just set them differently, slightly above freezing for the rooms you aren't in and a comfortable living temperature in the room you're in.
And mistakes by installers will cost even more. Our installers didn't flare a line set connection properly and it leaked slowly and that was a very expensive bill (especially since refrigerants have changed so much).
Our Daikin indoor units have also had condensate leaking issues, probably due to poor installation.
Ductless heat pumps do seem like the future but I think there are issues with regards to condensate draining, air filtering, and indoor unit cleaning/maintenance and replacement that could be done much better.
I sourced opinions far and wide and in the end it seemed to be a coin toss between Mitsubishi Electric and Daikin. A lot of it comes done to parts availability, and both seem very strong in Australia.
I once looked at a house with a new GSHP horizontal loop installed in the desert southwest US. I talked to the installer and they said the loop was only 12” deep. There’s no way the ground maintains steady temp at that depth, meaning you’re losing efficiency in the hot months when you need it most. Not to mention thermal pollution which will exacerbate the problem and the risk of hitting the loop with even minor ground work. They were adamant it was a good design.
Unfortunately, many installers jump on the bandwagon without the necessary expertise.
Cleaning basically involves a dedicated cover + drain that diverts water to a bucket, and blasting it with what's effectively a "low power pressure washer" I can use indoors (carefully), and "Lemocide" to properly disinfect... And coil cleaner for the fins. Takes me a good 4+ hours per unit, largely spent preparing the area in case there is any rogue spray. (Though TBH I may be a bit obsessive about getting it right.)
I also had a drain leak as you mentioned -- blasting the drain line with aforementioned "low pressure washer" helped with that. Still a bit gross to deal with. (And learning how to properly disassemble and clean the drip tray is the final thing I've put off leaning for a completely-thorough deep clean... I'm a bit horrified anticipating what I'll find...)
So far, it seems to be working! Better than relying on everyone to manually do it (literally this is the instruction in the Mitsubishi Electric user manual).
Yes, over time - any amount of moisture will produce some mold. But it will be negligible.
But one problem is the dust in the house. It will collect on the unit and hold moisture and give a great substrate for mold to grow. But regular cleaning usually takes care of that.
Most of the videos from HVAC people are... sketchy to the say the least.
I've seen videos where they dismantle the whole indoor unit and leave the coil just hanging from the line set or zip tied to the backplate while they take the fan and drain pan outside to clean.
One easy thing we've found that helps with drain clogs is to use a shop vacuum from outside to suck it out (using a towel/rag to get a good pressure seal). Takes around 5 minutes per drain per cooling season.
This video shows a similar process using water pressure to clean the unit: https://www.youtube.com/watch?v=xcIVAv8YbPQ
Some more tips and modifications:
- I cover the electronics in a garage bag held with tape. No need to unscrew the black cover over the power wires to disassemble (I unnecessarily removed this a few times heh).
- I ended up really liking this cleaning shrowd after trying a few; the hard pieces on the sides are key for making it easy to secure nicely, which many others lack: https://www.amazon.com/gp/aw/d/B083S85X97
- I spend more time (like 30min+) spraying the blower wheel so it spins. I alternate spraying with fresh water with spraying diluted "Lemocide" (@10% dilution) from a spray bottle a bunch of times depending how dirty it is. I use this <https://snowjoe.com/products/sun-joe-wa24c-lte-24v-150-psi-m...> which at 100 PSI is 10x stronger than a hand pump sprayer, but 10x weaker than a real pressure washer. I.e. the sweet spot IMO.
- I use foaming coil clean from a can to clean the fins if they're particularly dirty. (WARNING: I have not used in the same cleaning as the Lemocide since I haven't confirmed if they're compatible, so be careful of any reactions if you use both in the same cleaning.)
- I take the outer casings outside for a quick rinse with the hose and dish soap if they're really dusty.
- I tape cheap plastic mirrors at 45 degree angle above the unit so I can see it from above and carefully vacuum the back coil (there are 3 folded over in a U, and you can only see 2 from the front). Otherwise this just accumulates junk and is hard to see. This also really helps with finding the 3x clips at the top of the case that secure it to the back housing.
I may have a few more notes worth sharing at some point; feel free to ping me if you have any specific questions.
Edit: See also this quick video on unclogging the drain line on a Daikin (though I used the sprayer against the tube instead of my mouth...): https://m.youtube.com/watch?v=GDrHe-rli98
Another great thing about having three seperate units is if one breaks, rare as it is, you're not stuck without heating / cooling.
I despair for the rental market right now. High prices and landlords are generally crap at amenities they don't personally use.
If you went with a common US brand you can get a good system with 4 units and a 36,000 BTU heat pump unit for around $6,500 USD installed.
I don't love the wall units - they're pretty ugly, even the new ones. If you're getting a mini-split, the in-ceiling or wall cassettes that are hidden are really the way to go IMO.
I got hung up on the excess line set idea and did a full DIY install of a non-DIY model mini-split. I bought, borrowed, and rented a lot of tools, spent a lot of time researching and learning. I really wish I went with the DIY model.
Despite that lesson, I may do it again when I finish my attic space, but this time I'll add copper line brazing to the list.
I’m mostly curious how these DIY units compare to Mitsubishi, which seems to be what all the installers recommend.
There are also DIY variants where a fixed line length comes from the factory with either a vacuum or a refrigerant in the line. The lines have metal seals on the fittings that are ruptured when torqued down on the equipment.
Stuff I had already specific to HVAC:
-R-410a manifold, gauges, and hoses.
Stuff I went out and bought:
-Nitrogen tank pressure regulator and hose for HVAC.
-Mandrel pipe bender
-Flaring tool
-Micron vacuum gauge
-A slightly better copper pipe cutter and deburring tool.
Stuff I rented/borrowed:
-Vacuum pump from Autozone. Free. It was plenty big enough for a minisplit.
-Full nitrogen cylinder rental from Airgas.
Things I'm glad I did:
-Used a wall mount instead of a pad for the compressor unit. Unit stays clean.
- Pressure testing with nitrogen. It's worth the money and effort to know up front it doesn't leak.
-Followed a more thorough procedure for vacuuming/drying which involves vacuuming down several times and flushing with nitrogen. I got a much better vacuum after subsequent flushes.
Great. You just eliminated approximately 15% of lazy screenwriter tropes for thrillers and action movies. Now they are forced to rely on replacing live surveillance camera feeds with a loop.
Same, and we have just implemented 2 x 7.1kw units along with about 7kwh solar panels. Our heating costs have plummeted and we can survive on days like today (17th Jan) with minimal impact to our comfort.
We are looking at changing water heating next as this is now the biggest part of our utility usage.
Heat pumps need to be scaled for the maximum heating or cooling load, whichever is greater. The optimal situation is that the heating and cooling loads are similar, but in colder parts of the U.S. the heating load is much larger than the cooling load and the case for the heat pump is not so good as a place where the need for heating and cooling are more balanced.
https://en.wikipedia.org/wiki/Syracuse,_New_York#/media/File...
the average temperature is below freezing for four months.
I guess that's the value of having a big heat sink, the Pacific Ocean, at your doorstep: temperatures are more stable.
When it's really cold out (say 25F or below), the heat pump stops for around 10mins to defrost the exterior coils, which means no heat running at all in that period, and this pause happens more frequently the colder it's outside. The end result, our ~1400 sq place took more than 24hrs to heat up from 55F to 72F when we got back after christmas.
Also you don't save any money on operating it, even with the efficiency yade yada the cost of electricity will run you more than the equivalent in nat gas. So nothing but downside.
My limited understanding of the defrost cycle is that it’s most a problem around 0c? If it’s a colder or warmer it doesn’t get triggered as often?
They're pretty quiet, too. You can certainly hear the air coming out, but it's fairly quiet and certainly wouldn't be noisy enough to bother you over tv, work, or anything else.
Ducts are dead.
The Daikin Alira X is the gold-plated option and cost $8k AUD for 2x2.5kw and 1x7.1kw units including installation. Payback time is about 3 years. The system is oversized, but enables excellent zoning and of course provides cooling which is a must on 40C/104F days.
Why do they seem to be so much more expensive in the US?