I could add the door cut back in, install return transfer grill, or look into adding a secondary heat recovery ventilator that acts independently of the primary HVAC system.
Or they buy new high efficiency windows and doors, and that 'tightens up' the house, but they don't also install an HRV (Heat Recovery Ventilator) to exchange outside air.
Having the foam crew do a blower door test for free if we go with them, so I guess I'll see. I live in climate zone 5a (cool, humid) so historically natural ventilation was used via induced pressure differentials generated by mechanical means (dryer, furnace, bathroom and kitchen vents). When we get new furnace and water heater that pull combustion air from outside, we're left with mostly manual means for generating negative pressure that drives infiltration. (But also wind, and pressure differentials caused by temperatures in winter)
In our case, we're definitely considering either an HRV or ERV to supply fresh outdoor air that we control (input and output CFM, MERV #). Our indoor air quality is poor enough to the point where we live with the tangible symptoms (Rhinitis), not just numbers on a sensor.
For those with interest in these topics, I suggest skimming a copy of one of the ASHRAE fundamentals handbooks[1]. It reads as a textbook but has incredible depth into the physical sciences that relate to building science, heating, cooling, and ventilation.
[1] https://archive.org/details/ashraehandbook2017hvacfundamenta...
And even if the installer air sealed your doors and windows, there are plenty more places for air to leak in.
You really need to run a blower door test to see if you need an HRV/ERV.
That must vary by region. I live in the PNW, and I have not seen a recently built house with a return in each room. One or more supply vents per room depending on size, one return for each floor seems pretty much standard.
But I wouldn't be the least bit surprised to find that there isn't really a specific reason, it's just "how we do things in this area." A surprising amount of building choices seem to be made that way.
We typically have returns in toilets, showers, etc. with one or more supply vents in each room; a large room may have several. Air flows in via supply vents, flows out under mandatory gaps in doors (if closed), through to the toilets and then outside. Moisture, CO2, and smells are constantly flushed in the right direction.
When the hood is on for cooking, air supply is typically enhanced so it doesn't mess up the overall pressure too much.
Incoming air is filtered, of course. The ventilation unit transfers heat from outgoing air to the incoming air to save energy and avoid problems with condensation.
In my home office, TVOC as measured by an Eve Room rarely goes above 100 (mostly happens when I pour an occasional whisky in the evening).
Old houses don't have ventilation machines at all, but rely on natural ventilation instead: warmer air flows upwards via chimneys and such due to gravity, pulling in fresh air from whatever gaps the structure has (accidental or purpose-built).
I guess the point is that it depends on when and where something was built. My most recent home is only a few years old and doesn't have a return per room and no code to say it should shouldn't.
[1]: https://en.wikipedia.org/wiki/Energy_recovery_ventilation
https://homes.lbl.gov/ventilate-right/step-3-whole-building-...
During Christmas Day visits with only a half dozen people the room CO2 spiked to over 1,000ppm. Older house from the 1970s no HVAC. Opening a window (cross draft) brought it down to 300ppm. The room was stuffy before and great after so it shows how sensitive we humans are to air quality.
But the parent is not inaccurate, for they did not mention "each year". Even 10 minutes North of Ottawa, I saw -42C, real, not just windchill, for a week, about a decade ago.
https://en.wikipedia.org/wiki/Highest_temperature_recorded_o...
But when it's 65-75°F outside in the spring/fall... CO2 builds up in my apartment like crazy. I keep the windows open and my bathroom fan on to try to suck fresh air in... but even so can't manage to really get it below 650, and with just a window cracked it sticks around 850.
It's really frustrating.
But to be fair, you may have a good point. Vehicle emissions and tire wear generates particulates consider to be ultrafine (0.1 max nanometer), which is even difficult for HEPA filters to deal with.
Hold on! Not all particulates are equally harmful - and by far!
A particulate sensor detects water vapor or particles of (non-burnt) cooking oil that are harmless to humans.
In the same way, it detects very dangerous (carcinogenic) compounds from combustion engines or burning coal or wood.
Cooking is in no way "insanely bad" (unless you are grilling your food black or cooking on an open wood/coal fire)
>“We know that inhaling particles, regardless of what they’re made of, is detrimental to health. Is it equally bad as inhaling exhaust from vehicle emissions? That we don’t know that yet,” [1]
Regardless, my sensor, at least, doesn't register water vapor as particulate. I can run an ultrasonic humidifier with distilled water to no effect on the measured PM2.5, or with tap water which will spike the particulates from the dissolved minerals.
1) https://www.theguardian.com/environment/2019/feb/17/cooking-...
"Natural gas and propane stoves can release carbon monoxide, formaldehyde and other harmful pollutants into the air, which can be toxic to people and pets."
https://ww2.arb.ca.gov/resources/documents/indoor-air-pollut...
"Gas stoves can generate unsafe levels of indoor air pollution"
https://www.vox.com/energy-and-environment/2020/5/7/21247602...
Also, the dangers of open flames are well known, unlike the ones of particulate.
I have no idea what the particles are though -- metal? Paint? Carbon from burnt residue? Or just whatever the heating element itself is made of?
Separately, cooking with gas (oven+stove) also sends CO2 way way up -- in my kitchen, from 500 to 1300 or so within 20 minutes. And that's with my range hood on.
Not saying that's the case here, but several times I thought the range fan was exhausting the air, only to learn upon examination that it was just shooting it back out into the same room.
Our current place has a proper kitchen, but the cooker hood vents outside directly next to the central heating boiler's intake.
You can't exactly throw the toaster oven in the sink and scrub the inside surfaces with steel wool and Barkeeper's Friend under running water like you can with pots and pans. Nor do toaster ovens have a "self-cleaning" cycle where you try to just vaporize it all... they simply don't get hot enough.
Do different PM2.5 components affect the body differently, even for the same overall count?
Eg, are the PM2.5 particulates from burning toast comparable in bodily health impact to a similar PM2.5 count coming from a heavy Diesel engine’s exhaust (which I presume would have a different particulate makeup).
[1] https://ehp.niehs.nih.gov/doi/full/10.1289/ehp.0800185?url_v...
I’ve found this varies quite a bit. Though, I don’t do a ton of high heat cooking, so maybe there’s no way to do that without pollution.
But at medium to low temperatures, you can get crazy variance in AQI output:
* Lack of enough oil/butter in the pan will send levels soaring
* Cooking one thing in the pan then another after is very bad. Eg I used to cook sweet potatoes then add meat after and not clean in between to save waiting. Boy was that bad for the air. I think it’s because tiny bits of food you may not even see stick to bottom of pan and burn
* Browning is when it gets worse. Any kind of browning on foods spikes pollution.
* Any food particle that gets on the burner will invariably lead to hazardous AQI levels. Like even a single fleck of meat left cooking will fill the house. You may not necessarily smell it as much as other things
* Turning heat off at end of cooking works wonders. I do this with bacon and it takes it from a hazard to not even spiking aqi. Finished product looks and tastes the same
I haven’t tested AQI with steak for example. And I can say that with bacon I have certainly managed to have it turn brown without pollution. But, once things are turning brown you are on thin ice and it is easy to go from “none” to “hazardous” in a flash.
What is the alternative?
I found bungee cord with J hooks works really well. As you correctly point out, you don't need to secure it at all, but it is annoying to tap the box fan and have the filter fall over.
Even just with two people working from home, much of the space would quickly get up to 800 or 900 ppm. I’d usually open windows as I saw it creeping up, which would quickly reduce CO2 to under 600, and then it would slowly creep up over the day.
Living here in the west with hyper toxic AQI for the better part of two months now, I decided that the low CFM and leakage of a DIY box fan are not adequate to keep up. I went with a far more industrial solution: I went to an indoor grow shop and bought an activated carbon filter and high CFM inline fan. Cost $150 and is a bit noisy, but has been well worth it.
That’s fairly high - what is the size and cfm of the fan you bought?
https://www.amazon.com/VIVOSUN-Inline-Controller-Ducting-Ven...
https://news.ycombinator.com/item?id=27125060
tl;dr: seems like you want an NDIR sensor (https://en.wikipedia.org/wiki/Nondispersive_infrared_sensor).
Some options, with digikey @1 prices:
Senseair S8 (Sweden): $48
Sensirion SCD30 (Switzerland): $63
Amphenol Telaire T6713 (US): $96
If I were to buy an expensive black box iot solution, I'd at least verify that it had an NDIR sensor.
It's pretty tiny... I wonder if/when it will be possible to put a high quality co2 sensor in an IP68 iPhone...
The problem with all this "intelligence" is the Internet is very good at showing you search results for what you want to see, so Googling "Should I be worried about fine particulates" is a search destined to turn your anxiety into a full-blown panic attack.
No idea what the answer is, and I am impressed with the level of effort that went into the Awair app, but it would be nice to have more reasonable context in all IoT devices. Yeah, I know.
I’ve also found that regularly glancing at the 5 minute resolution charts of just temp and humidity has helped me get a better sense of my own comfort range…for example I like to run my AC as little as possible in the summer, but I’ve learned that playing chicken with the heat is foolish beyond 81F as I only wind up sitting at my desk grumpy and unproductive.
With any IoT device I’m wary about longevity re app support, I can’t say how long Awair will support this device or whether they’ll provide access to it after they stop, but I’m less concerned for a device like this vs, say, a major appliance.
It’s got an eink screen, and I haven’t had to recharge it since I got it 8 months ago. I really like it.
Now I really need to investigate more details - like does induction cooking (vs. gas) improve the quality? What about the type of food (ie, cooking vegetarian vs. grilling sausages)?
weeps in searing steaks with no hood at all :'(
And what is the boxfan hack? I live near very bad wild fires and I need a much better filtering then my current grow filter which doesn't seem to work that well.
you just put a fan filter on the back, you can increase the amount of filters to not hurt the fan motor as much by making a triangle config or fan on top of 4 filters in a cube. fans are for air throughput not static pressure so real air purifiers have squirrel cage blowers
Literally just a box fan w/ a hvac filter taped to it. There are a few articles/youtube videos where people claim it works a lot better than a fancy air filter+fan device that costs $100s.
If you try it, just be careful it doesn't burn the fan motor and/or cause a fire.
>The EPA funded a study by Underwriters Laboratories (UL) which tested box fans with MERV-13 filters attached, finding them to not present a fire hazard even in extreme, modified conditions.
Then it links to, https://chemicalinsights.org/wp-content/uploads/DIY-Box-Fan-...
which says,
>Two-Sided Obstruction
>Figure 6 shows the time series of monitored temperatures under extreme condition where both sides of the fans were blocked. Despite the severe blockage of air flow, temperatures of all five box fans peaked within the first 20 minutes and then plateaued, remaining steady for the remaining 7 hours. Winding temperatures had the largest relative increase of 30 to 57 °C above ambient temperature, with peak absolute winding temperatures remaining at or below 80 °C. Peak temperatures on other fan parts did not exceed 50 °C.
> Temperatures at the power cord, guard, and switch, remained close to ambient room temperature (±6 °C) during all filter test scenarios as well as during the one-sided blocked tests. For the two-sided blocked tests, temperatures at the power cord, guard, and switch increased initially before plateauing to a steady temperature for the remainder of the 7-hour test duration. All fans remained operational for the 7-hour test duration and did not show any signs of potential hazard or damage.
- Cooking is insanely bad for the air in your house, even with an outside-venting hood. Any sort of medium-high heat cooking will spike the PM2.5 to multiple times that of the haziest days here in NYC, and with the windows shut it will stay elevated for hours after.
- The 20" box fan + MERV furnace filter hack is super effective for cutting down on the PM. A few days this July the wildfire smoke from the west coast settled on NYC and we had 40-70 ug/m3 PM2.5 outside. The box fan filter took it down to around 5 in a matter of minutes. I didn't even bother taping the filter to the fan.
- My A/C system's ability to precisely hold the temperature within fractions of a degree of the thermostat setting is impressive.
- With two people working from home in an old, unventilated-but-kinda-drafty ~700 square foot apartment, the only thing that gets the CO2 levels into "drowsy" territory (my original point of curiosity when buying the sensor) is running the gas oven for a while.