I think the draftiness is key. In my findings, in a "modern" house (double-paned windows, built in the last 20 years), sleeping with the door closed will spike CO2 to 4 digits. The other thing is that air really needs to circulate in order to lower CO2 - opening a window in a room will not lower the hallway CO2 unless there's at least some draft / air movement.
Re:Monitoring my home's air quality with AirGradient's DIY s... by nsporillo on Wednesday September 08, 2021 @12:53PM (#28459769)
In a modern home, there should be supply and return vents in every room. My home built in 1978 has 3 returns for the entire house, one on each floor. Master bedroom has a supply, but the return is located in the hallway. Over the years, the recommended door cut to allow air flow has been changed (presumably for greater privacy) - which leads to the scenario you're describing.

I could add the door cut back in, install return transfer grill, or look into adding a secondary heat recovery ventilator that acts independently of the primary HVAC system.

Re:Monitoring my home's air quality with AirGradient's DIY s... by geerlingguy on Wednesday September 08, 2021 @02:03PM (#28460844)
I know many people who put 'draft stop' devices on the bottoms of their bedroom doors in older homes (old enough to not have returns in each room, but new enough for central air), not realizing they're cutting off the one bit of circulation they need for a proper functioning central air system!

Or they buy new high efficiency windows and doors, and that 'tightens up' the house, but they don't also install an HRV (Heat Recovery Ventilator) to exchange outside air.

Re:Monitoring my home's air quality with AirGradient's DIY s... by nsporillo on Wednesday September 08, 2021 @02:20PM (#28461082)
Realistically new windows and doors probably wont drop the homes air changes per hour below the recommended minimums, but I don't know for sure. I've gotten my crawlspace spray foamed and I'm getting my vented attic spray foamed to bring it into my envelope. Also getting new windows and doors soon, but after all of that I think enough air could leak through sill and top plates, electrical outlets, etc.

Having the foam crew do a blower door test for free if we go with them, so I guess I'll see. I live in climate zone 5a (cool, humid) so historically natural ventilation was used via induced pressure differentials generated by mechanical means (dryer, furnace, bathroom and kitchen vents). When we get new furnace and water heater that pull combustion air from outside, we're left with mostly manual means for generating negative pressure that drives infiltration. (But also wind, and pressure differentials caused by temperatures in winter)

In our case, we're definitely considering either an HRV or ERV to supply fresh outdoor air that we control (input and output CFM, MERV #). Our indoor air quality is poor enough to the point where we live with the tangible symptoms (Rhinitis), not just numbers on a sensor.

For those with interest in these topics, I suggest skimming a copy of one of the ASHRAE fundamentals handbooks[1]. It reads as a textbook but has incredible depth into the physical sciences that relate to building science, heating, cooling, and ventilation.

[1] https://archive.org/details/ashraehandbook2017hvacfundamenta...

Re:Monitoring my home's air quality with AirGradient's DIY s... by turtlebits on Thursday September 09, 2021 @12:04AM (#28466078)
High efficiency windows and doors don't tighten up a house when it comes to air leakage. They bump up your thermal performance/energy efficiency.

And even if the installer air sealed your doors and windows, there are plenty more places for air to leak in.

You really need to run a blower door test to see if you need an HRV/ERV.

Re:Monitoring my home's air quality with AirGradient's DIY s... by tsjq on Wednesday September 08, 2021 @11:30PM (#28465881)
these things are almost never mentioned in the "money saving tips" blogs , "lifehack articles" , r/frugal advice, etc places.
Re:Monitoring my home's air quality with AirGradient's DIY s... by rootusrootus on Wednesday September 08, 2021 @03:53PM (#28462201)
> In a modern home, there should be supply and return vents in every room.

That must vary by region. I live in the PNW, and I have not seen a recently built house with a return in each room. One or more supply vents per room depending on size, one return for each floor seems pretty much standard.

Re:Monitoring my home's air quality with AirGradient's DIY s... by windexh8er on Wednesday September 08, 2021 @05:02PM (#28463025)
Interesting. I live in the upper midwest and remember my first home I lived in (parents built it new in 1980) had returns in every room. My current home is primarily forced air and there are returns in every room with multiples in the larger gathering spaces. Was built in the late 90s and I think building code may require a specific number of returns per square foot.
Re:Monitoring my home's air quality with AirGradient's DIY s... by rootusrootus on Wednesday September 08, 2021 @06:41PM (#28463960)
Could be regional -- I would bet that in most cases houses in the upper midwest have to deal with much colder temperatures in the winter than houses in the PNW. Maybe that influences the HVAC design.

But I wouldn't be the least bit surprised to find that there isn't really a specific reason, it's just "how we do things in this area." A surprising amount of building choices seem to be made that way.

Re:Monitoring my home's air quality with AirGradient's DIY s... by metafunctor on Thursday September 09, 2021 @04:15AM (#28467462)
Over here in Finland, nobody has returns in each room. It's a cold climate, so houses are heavily insulated, and moisture condensation is a concern during the winters.

We typically have returns in toilets, showers, etc. with one or more supply vents in each room; a large room may have several. Air flows in via supply vents, flows out under mandatory gaps in doors (if closed), through to the toilets and then outside. Moisture, CO2, and smells are constantly flushed in the right direction.

When the hood is on for cooking, air supply is typically enhanced so it doesn't mess up the overall pressure too much.

Incoming air is filtered, of course. The ventilation unit transfers heat from outgoing air to the incoming air to save energy and avoid problems with condensation.

In my home office, TVOC as measured by an Eve Room rarely goes above 100 (mostly happens when I pour an occasional whisky in the evening).

Old houses don't have ventilation machines at all, but rely on natural ventilation instead: warmer air flows upwards via chimneys and such due to gravity, pulling in fresh air from whatever gaps the structure has (accidental or purpose-built).

Re:Monitoring my home's air quality with AirGradient's DIY s... by twothamendment on Thursday September 09, 2021 @01:07AM (#28466447)
In the last decade I built 2 houses in the same neighborhood over 6 years. The first didn't require a return per room and the second one did - they had changed their code. A few years later and they had reversed their decision.

I guess the point is that it depends on when and where something was built. My most recent home is only a few years old and doesn't have a return per room and no code to say it should shouldn't.

Re:Monitoring my home's air quality with AirGradient's DIY s... by herbst on Thursday September 09, 2021 @04:46AM (#28467635)
Pretty sure this is mostly American. Assuming your bath has a window it's not unlikely there are zero returns in central Europe.
Re:Monitoring my home's air quality with AirGradient's DIY s... by rainbowzootsuit on Wednesday September 08, 2021 @07:49PM (#28464469)
A 1" door undercut is only about equivalent to a 6" duct in cross section and that size should max out at 120 ft^3/min with well installed duct. If you have more supply then there will be airflow issues in that room/house.
Re:Monitoring my home's air quality with AirGradient's DIY s... by davemp on Wednesday September 08, 2021 @12:46PM (#28459663)
That's why an ERV [1] is important in a modern house with good air tightness.

[1]: https://en.wikipedia.org/wiki/Energy_recovery_ventilation

Re:Monitoring my home's air quality with AirGradient's DIY s... by withinrafael on Wednesday September 08, 2021 @02:06PM (#28460893)
Our multi-room apartment in Redmond, WA, has an always running intake fan in the master bathroom advertised as a way to keep air fresh. I always wonder how effective that really is (at apartment scale) and if it's really worth the 24/7 power draw.
Re:Monitoring my home's air quality with AirGradient's DIY s... by velosol on Wednesday September 08, 2021 @08:53PM (#28464953)
Almost certainly designed to ASHRAE 62.2's specs so that you get enough ventilation through a combination of infiltration (leakage) and additional mechanical ventilation. It's certainly worth it and if designed as a continuous ventilation fan should be one of the lower (~15W) draw units. Not sure how to really measure effectiveness other than by trusting in the experts who came up with the spec and air quality as an indirect measure.

https://homes.lbl.gov/ventilate-right/step-3-whole-building-...

Re:Monitoring my home's air quality with AirGradient's DIY s... by asdff on Wednesday September 08, 2021 @02:15PM (#28461011)
Probably more for preventing mold damage from lazy tenants I imagine.
Re:Monitoring my home's air quality with AirGradient's DIY s... by hourislate on Wednesday September 08, 2021 @02:19PM (#28461073)
It's to keep positive pressure in your unit for safety purposes. If there is a fire the fresh air will help keep smoke out of your unit and as a bonus it keeps other building odors out. Generally it is a large fan on the roof that just sucks air down a stack pumping it into every unit. You could put a filter over the register and filter that air.
Re:Monitoring my home's air quality with AirGradient's DIY s... by zz865 on Wednesday September 08, 2021 @03:59PM (#28462279)
Its probably the opposite, it sucks out air. It does stop smells from this apartment going into neighboring spaces.
Re:Monitoring my home's air quality with AirGradient's DIY s... by withinrafael on Wednesday September 08, 2021 @02:27PM (#28461165)
Sorry, by intake I meant it's sucking air in. That is, air is leaving my apartment. I think you're on the right track with the safety angle here though. Will do more research.
Re:Monitoring my home's air quality with AirGradient's DIY s... by bbarnett on Thursday September 09, 2021 @07:08AM (#28468416)
Air is leaving, thus, it is being sucked out of the apartment.
Re:Monitoring my home's air quality with AirGradient's DIY s... by dghughes on Wednesday September 08, 2021 @09:03PM (#28465018)
I bought my parents a Netatmo weather setup. The one in the house measures temp, CO2 and the one outside temp, humidity.

During Christmas Day visits with only a half dozen people the room CO2 spiked to over 1,000ppm. Older house from the 1970s no HVAC. Opening a window (cross draft) brought it down to 300ppm. The room was stuffy before and great after so it shows how sensitive we humans are to air quality.

Re:Monitoring my home's air quality with AirGradient's DIY s... by 5e92cb50239222b on Wednesday September 08, 2021 @12:40PM (#28459573)
Temperature difference helps if there's no wind. In winter time CO₂ drops from 4000+ ppm to ~450 in only a couple of minutes after opening a single window (with inside to outside temperature difference of 50°C or higher). In summer it drops to ~600-700 and stays there, and even this takes hours.
Re:Monitoring my home's air quality with AirGradient's DIY s... by y4mi on Wednesday September 08, 2021 @01:23PM (#28460239)
50°C difference or even higher? Damn mate, even Siberia only gets around -34°C which is less then that of you target the usual 18-21°C. Your winters sound terrifying.
Re:Monitoring my home's air quality with AirGradient's DIY s... by theluketowers on Wednesday September 08, 2021 @01:48PM (#28460602)
Saskatchewan Canada can easily reach -40°C for several weeks during the winter.
Re:Monitoring my home's air quality with AirGradient's DIY s... by JamisonM on Thursday September 09, 2021 @12:47AM (#28466320)
What? Maybe in the most northern reaches.. even then "for several weeks" is a stretch.. even Uranium City doesn't hit -40°C every winter!
Re:Monitoring my home's air quality with AirGradient's DIY s... by bbarnett on Thursday September 09, 2021 @07:16AM (#28468456)
There is often confusion between wind chill, and actual temps.

But the parent is not inaccurate, for they did not mention "each year". Even 10 minutes North of Ottawa, I saw -42C, real, not just windchill, for a week, about a decade ago.

Re:Monitoring my home's air quality with AirGradient's DIY s... by freeopinion on Wednesday September 08, 2021 @04:28PM (#28462614)
Winters? I thought they were referring to this last May or the previous August.

https://en.wikipedia.org/wiki/Highest_temperature_recorded_o...

Re:Monitoring my home's air quality with AirGradient's DIY s... by y4mi on Thursday September 09, 2021 @01:44AM (#28466673)
He specifically said winter but having 68-74°C at minimum sounds terrifying too, honestly
Re:Monitoring my home's air quality with AirGradient's DIY s... by crazygringo on Wednesday September 08, 2021 @02:06PM (#28460897)
That's what I've discovered over the past year! I live in NYC and my CO2 levels are fine in both the winter and on hot summer days, without even trying.

But when it's 65-75°F outside in the spring/fall... CO2 builds up in my apartment like crazy. I keep the windows open and my bathroom fan on to try to suck fresh air in... but even so can't manage to really get it below 650, and with just a window cracked it sticks around 850.

It's really frustrating.