It looks like they wanted a California house, with flat a roof and giant windows, in the Canadian Wilderness. But there's a reason houses in the mountains look the way they do. This house looks as out-of-place as a ski chalet would on the beach in San Diego. In any case, it looks as if they have enough money not to care.
They're going to have a hell of the time with the weathering on that siding and roof in 10y, too.
And while the sliding glass doors look like they are single paned, look at the quadruple reflection. Isn't that usually caused by multiple sheets of glass in close proximity?
The external framing is also 2x6, so someone was thinking about insulation. I think it's just that after declaring victory on a well insulated house they then decided to heat the outdoors anyway by directly heating things that are out of doors.
Yes, compared to other windows. Compared to a well-insulated wall with external insulation and 6" of interior insulation, they're not great.
Good windows are an R5. A well-insulated wall cavity can easily be an R30.
I knew a person who tried to put in triple-glaze, in New Westminster, BC, and it took a special lien on the property along with special approval from the Province because they weren't allowed by the building codes at the time.
That was ~10y ago, so maybe it's changed now.
Millions of hectares burn down every year:
https://en.wikipedia.org/wiki/2017_British_Columbia_wildfire...
https://en.wikipedia.org/wiki/2018_British_Columbia_wildfire...
Last year an entire town disappeared:
https://www.cbc.ca/radio/thecurrent/the-current-for-sept-7-2...
[0]https://www2.gov.bc.ca/gov/content/transportation/driving-an...
[1]https://www.arcgis.com/apps/dashboards/f0ac328d88c74d07aa2ee...
[1] https://www.providencejournal.com/story/news/2021/05/17/larg...
The two combine into large, periodic forest Fires.
The east coast has much fewer unbroken tracts of forest, and where it does have them they are more heavily managed and stewarded for a number of reasons.
The east coast was developed and property subdivided/allocated long before the tendency towards large national parks, monuments, etc.
It isn’t that these national parks or forests cause all these problems (though many of them DO feature prominently in these huge fires), they are also a sign of the very different nature of land allocation during the settling of the area.
You can see this pretty clearly if you pull up maps of federal land (national forests, national parks, blm land, etc). Several western states have more land owned by the federal government than anyone else.
They are all out west.
And the pine beetles are doing a number on BC. It's only a matter of time before those catch on fire.
The drainage will clog and they’ll risk having a leaky roof every spring. And you can’t get up there with a snow shovel because it’s a green roof and you’d scrape off all the dirt and plants.
(Oregon has one semi-famous flat-roofed house that I'm aware of, designed by Frank Lloyd Wright. I suspect FLW hadn't actually ever been to Oregon: it looked like a house that belongs in Arizona or California. Anyways, the eventual owner of the land the house is built on wanted to tear it down and build a mansion, and after much protests they allowed some people to come in and take the house apart and reassemble it near Salem. After putting it back together, they found some of the original contractors who had built the house originally. Supposedly they took a tour of the house and declared that it must have been properly reassembled, because the roof leaks in all the same places.)
https://en.wikipedia.org/wiki/Gordon_House_(Silverton,_Orego...
A lot of people have inground pools here in Quebec. AFAIK it's just a matter of removing some of the water before it freezes, to minimize the effects of expansion. It does tend to generate small cracks, but nothing that can't be patched over with annual maintenance.
(Love your username, btw)
[0] https://www.davos.ch/en/information/portrait-image/storybook...
I wish they had detailed how flat roofs guards against an avalanche? What is the logic/physics at work there?
https://www.webcenterfairbanks.com/2021/04/04/spring-melt-me...
I also think it's ridiculous, for what it's worth. 400A is a wild amount of electricity for a supposedly high efficiency, modern home.
Hot tubs are also rather small.
But a hot tub? There are very, very few bodies of water that you can submerge comfortably in that doesn't end up being a non trivial amount of energy to warm up, much less keep warm.
To each his own I guess.
A proper Sauna would have satisfied them both!
I still don't get though, if living in rural area, why not heat the pool with wood. It just has that sensation that electric heater doesn't provide.
‘Wood warms you up three times. Once when you cut it, once when you split it, and once when you burn it’.
The amount of manual labor and time required to keep a pool warm from wood is monumental. It will definitely keep a fit man in the prime of his life busy and tired.
It isn’t something to sign up for lightly, especially for someone who may not have that kind of physical strength (or want it spent on heating their pool).
Is this some kind of new homeopathy? Wood memory gets into the water making two types of heat have a different sensation?
Why would it be harmful to run at the amperage that I'm buying ? What disincentives do I need?
Seconded. I recently completed an all electric high performance remodel, and with 200A service, I can power a heat pump, heat pump water heater, all electric kitchen and laundry, and an EV charger, with Amps to spare. This is in the mild Bay Area, and my heat pump draws about 6A (15A breaker). The largest loads are EV and cooktop/stove.
A 3000sqft custom house built to high performance standards (airtight and well insulated) can be space heated in a cold climate with a heat pump that draws no more than 24A (40A breaker) using a heat pump. At that load a modern heat pump will make 40kBTU of heat. There are many examples of this across Canada.
I just now read that they have an outdoor heated pool, though, so crazy as it sounds they are presumably using electricity to heat it.
> plus propane.
Apart from backup water heating when the power goes out, their hot tub will waste huge amounts of energy, so propane might be operationally cheaper than electricity.
Edit: Service in the US is generally 200A or 400A. I'd say 400A is overbuilt for what they have, but that doesn't mean they actually use much of that capacity.
For example, I average 1000 kWh per month, which is about 1.39 kW 24/7, or 12 amps average on my 200A service. The 200A is to have headroom for peak demands, and we probably never get close to 200A.
If I were to rewire my panel (it's full), I'd go for the 400A - it's just heavier copper in the three lines to the entrance panel. That would not increase my monthly power bill right now, but it would provide lots of excess capacity in case I want to switch to heat pumps and electric vehicles.
Since we heat with wood and propane and don't use electricity for either and have mostly LED lighting and a gas stove, I do wonder where all the power is going, especially at night. Too many computers, I guess. Add analysis to my to-do list!
Assuming you are using are using a resistance heater (100% heating efficiency), to raise 200Gal of water (typical small hot tub size) from 50F to 100F requires about 25kWh of energy.
To only use 75kWh/month (255kBTU), you would need to only raise it to 100F less than 3 times a month, and that assumes that the water temp doesn't naturally drop below 50F (unlikely in NH).
It's likely you are spending significantly more than $15/month to heat it with electricity.
Propane is about $30/MBTU, which would work out to about $9/month for the equivalent amount of heat.
1. https://www.electricrate.com/residential-rates/new-hampshire...
2. https://bloglocation.com/art/water-heating-calculator-for-ti...
The tub is well insulated, with an insulated cover, so you need to account for that. My estimate on the hot tub cost is by comparing my kWh usage after the tub was installed to the prior year use.
Most small tubs are electric, like mine.
So assuming $15/month, you are using 115kWh, which is 392kBTU of heating energy. It takes about 83kBTU to heat 200gal of water from 50F to 100F, which would be like 5 full heat ups from 50F. Of course there are the other convolved factors you mentioned (insulation).
I like my wood/propane mix for heating, because it's immune to power outages. At some point I'll get too old to cut/split/haul wood, though, and will have to figure something else out.
I'm not sure why there's a push to eliminate gas cooking in favor of electricity. Perhaps some people are concerned with methane leaks in the natural gas distribution system.
It can make a lot of sense in urban areas. In addition to removing the methane leaks (with their high GWP), it reduces the need to install/maintain expensive natural gas distribution infrastructure, and also improves indoor air quality by eliminating NO2 and CO production within the house. If the power goes out, you just use a propane grill in the backyard, or a small butane stove.
S̶p̶e̶c̶i̶f̶i̶c̶a̶l̶l̶y̶,̶ ̶f̶o̶r̶ ̶t̶h̶o̶s̶e̶ ̶w̶h̶o̶ ̶w̶e̶r̶e̶n̶'̶t̶ ̶a̶w̶a̶r̶e̶,̶ ̶s̶m̶a̶l̶l̶ ̶h̶o̶t̶ ̶t̶u̶b̶s̶ ̶a̶r̶e̶ ̶t̶y̶p̶i̶c̶a̶l̶l̶y̶ ̶h̶e̶a̶t̶e̶d̶ ̶t̶h̶r̶o̶u̶g̶h̶ ̶f̶r̶i̶c̶t̶i̶o̶n̶ ̶a̶n̶d̶ ̶w̶a̶s̶t̶e̶ ̶h̶e̶a̶t̶ ̶f̶r̶o̶m̶ ̶t̶h̶e̶ ̶c̶i̶r̶c̶u̶l̶a̶t̶i̶o̶n̶ ̶p̶u̶m̶p̶s̶ ̶a̶n̶d̶ ̶d̶o̶n̶'̶t̶ ̶h̶a̶v̶e̶ ̶d̶e̶d̶i̶c̶a̶t̶e̶d̶ ̶w̶a̶t̶e̶r̶ ̶h̶e̶a̶t̶e̶r̶s̶.̶ ̶Y̶o̶u̶ ̶c̶o̶u̶l̶d̶ ̶a̶d̶d̶ ̶a̶ ̶s̶e̶p̶a̶r̶a̶t̶e̶,̶ ̶m̶o̶r̶e̶ ̶e̶f̶f̶i̶c̶i̶e̶n̶t̶,̶ ̶w̶a̶t̶e̶r̶ ̶h̶e̶a̶t̶e̶r̶ ̶a̶n̶d̶ ̶r̶u̶n̶ ̶t̶h̶e̶ ̶p̶u̶m̶p̶s̶ ̶l̶e̶s̶s̶ ̶o̶f̶t̶e̶n̶,̶ ̶b̶u̶t̶ ̶i̶t̶'̶s̶ ̶n̶o̶t̶ ̶a̶s̶ ̶s̶i̶m̶p̶l̶e̶ ̶a̶s̶ ̶r̶e̶p̶l̶a̶c̶i̶n̶g̶ ̶o̶n̶e̶ ̶k̶i̶n̶d̶ ̶o̶f̶ ̶h̶e̶a̶t̶e̶r̶ ̶w̶i̶t̶h̶ ̶a̶n̶o̶t̶h̶e̶r̶.̶
Never mind. Apparently I was misinformed. The circulation pump moves the water through the heater, but isn't the primary heat source.
It's that, as well as the fact that having a gas stove means you have a gas hookup in the first place, so you're more likely to also use it for heating. That in turn leads to more emissions than other heating methods produce.
That’s an almost ideal case for an air-to-water heat pump though, the heat capacity and efficiency of which go up as the output water temperature goes down. Pool heating (and snow melting) are ideal use cases that can support a very low output water temperature and still get the job done (as compared to baseboard or cast-iron radiator space heating).
[0]: The incoming line was aerial and over the legal span length, so it had been attached to an insulator nailed to a tree halfway between the house and mast. Also the mast was deteriorating to the point that it needed to be replaced anyways and insurance was making noise about not allowing a new policy if it wasn't upgraded to at least 120A. We did a customer pole and went underground to the house. Much nicer aesthetics and I can now turn off a breaker on my side of the meter at the pole to do maintenance.
https://www.thespruce.com/service-panels-changed-in-the-1900...
Which says 100A didn't become common until the 1960's.
Maybe they have a heat pump setup which switches to propane when it gets really cold.
Wood is there, but somebody needs to feed it. And people inevitably get old or lazy about it and depend more and more on the convenient heat sources available.
A lot of hydro power is ‘use it or lose it’, since the dams also provide flood control and MUST keep extra capacity free to absorb sudden water surges. They can’t just store everything they get.
Most places in the US experience much harsher seasons than the Bay Area.
Then there are places like Nevada, which are just not suitable for large-scale habitation. "Can we make this monument to our hubris more energy efficient" is kind of missing the point, right?
> A goal for the build was to limit impact to the site during construction, and then to limit the footprint of the home after completion. In pursuit of this we planned an efficient mechanical design that would feature solar panels for electricity generation tied to the grid, geothermal for heat exchange, and no fossil fuels.
Oh, great, sound like you have some good environmental principles!
> However, we quickly ran into several problems with this approach.
Yeah, it can be a bummer to sacrifice your own comfort. But it is worth it for the environment!
> The bigger issue was that the energy demands for the house, which included hot water heating for the pool and hot tub, outstripped the electrical supply we could get on a rural residential build: 400A.
Wow, that's a lot of electricity. Like, a loooooot. Maybe we can pare it down a little bit -- limiting our impact is important, right?
> We eventually settled on supplementing our electrical generation with propane, which we had hoped to avoid
Right?
O-oh. Oh so you're using propane to heat the pool.
Yeah.
I dunno, maybe my thought is unrealistic - but if I were to splash out a ton of money for a palatial rural manse, I'd shoot for something with a bit more space than a large-ish suburban home.
Especially because one of the most common uses of such a property is entertainment - forget having folks stay over unless you make the kids bunk?
So how are they going to be entertaining people all the time (they specifically mention entertaining large groups being important to them)? Come over for an evening, except one of you can't drink and has to drive 2 hours back at the end of the night??
At a bare minimum it needs to be large enough to have a guest suite - the central socializing spaces like the kitchen and living room also need to be scaled for that use.
Ideally (assuming a grand budget) you can have separate structures for guests entirely.
But certainly one has to assume that guests are bunking over, given how remote the location is. It seems eminently unreasonable to assume guests are driving several hours at the end of the evening.
To which end, I wonder how long such a home would last, given the upkeep. The bling times come and go. Just look at history.
3-5 years at most I think. I've seen futile attempts to sell such experiments.
After that time it's just easier to bulldoze or burn it, and then build something more sensible.
Still, it's a very high amount of power (48kW) that would not even be subscriptable in France for a consumer (the max is 36kW).
Remember, they didn't want fossil fuels - if you are going all electric, especially for heating (in CANDADA!) you are going to pull some wattage.
That big outdoor pool - in CANADA - doesn't help either.
Cool house though.
A 230/400V open Y service at 25 amps is just 10kW which to me sounds like an old standard or mains for a small 1-2br apartment. I'd expect at least a 50-60A service. Though I know some (many?) homes in EU are on actual 3 phase so 25A at 400V 3 phase becomes 17.3kW which is not far from the 24kW a 100A 120/240 service provides. Still anemic but quite a bit of power for a 1-4 person household living modestly. Though in the USA it seems utilities make residential 3 phase difficult or impossible to obtain as you might do commercial stuff with that electric without paying commercial rates or your neighborhood is served by a single phase feeder.
Depends on the trip curve and the age of the overcurrent device. Looking at the trip curve for a Fuji BW250 (125-250 amp frame size), at 150% the device will trip in what looks like 5-30 minutes. Any load over 10x rated current is an instant trip.
There was a scandal many years ago where an electrical equipment manufacturer, Federal Pacific, was caught rigging its testing machines to pass faulty or poorly performing circuit breakers. It was found that some of those breakers would carry 150%+ rated current without tripping. They were responsible for quite a few electrical fires and were sued into oblivion.
No, I thought that was a typo and should be 40A (so 120V * 40 A or 400V * 12A).
[0] https://app.bchydro.com/accounts-billing/electrical-connecti...
It could just be to handle momentary bursts, and the equipment drawing that power might actually be doing the job more efficiently than something that does it slower, drawing more power cumulatively over a longer period of time.
The idea is that you don't want more energy in the panel than the panel is designed to handle. Practically (if I understand it right) this means that the breaker for the solar panels is limited to 20% of the panel rating. A 200A 240V panel would limit you to a 40A 240V breaker, which (according to the link above) means a maximum of 7.6kW of backfeed solar.
In the article, he says he has a 11.6kW solar array, which would require (if I'm calculating right) at least a 60A 240V breaker (maybe plus some required overcapacity?). Since this isn't allowed on a 200A panel, he may have needed to bump up to the next largest size of 400A unless he wanted to go smaller on the solar array. So while it sounds like overkill, it's possible there is more reason for it than just a desire to heat his wife's outdoor pool in the winter.
so 100A panel + 100A of solar requires a 200A panel
A few other things that require high-amp service - on demand electric water heating, and electric car charging (and we're moving towards multiple vehicles).
It's also worth mentioning that by far the largest cost of an electrical circuit is the labor, so sizing for 100A, 200A and 400A is not 1x, 2x, 4x. upgrading later is a huge cost.
That, and tankless water heater are stupid, frankly.
Fossil fuels are from carbon sources taken out of the normal carbon cycle (aka buried generally)
(This is way outside of my expertise so I appreciate if you tell me what's wrong with my logic.)
If you chop it down and burn it, or it dies and rots, +1 tree of carbon goes back. But the total carbon in the system hasn’t changed, and on average (if this happens a lot everywhere), the amount of carbon in the atmosphere is pretty much the same.
nothing lives forever, and most things stop growing quickly pretty fast. Unless there is a huge disaster, forests turn over in a stable way generally - new trees always growing, old trees always dying and rotting.
So unless you had chopped down massive forests and stopped new trees from growing, or stockpiled half a continents worth of wood for a century and then decided to burn it all at once, it’s hard to meaningfully change the average amount of carbon in the atmosphere, because it never really stops ‘moving’ or gets out of the cycle.
Fossil fuel is carbon that got pulled out of the system a long time ago - those trees or ferns or peat or whatever got stuck underground, where they couldn’t rot or burn, and on a scale that IS continents worth of trees, for millions of years. We don’t know what it is like having that amount of carbon in the system, because the last time it was in the system was millions of years before we existed.
Once those fossil fuels get burned, even if you plant trees, it doesn’t really reduce the amount of carbon back to where it was, because those trees will die and rot or burn or whatever, and on average, the total amount of carbon in circulation is now higher.
Does that help?
You can limit the charging current but at some point you will have to make compromises on driving.
this is all for one car.
For multiple cars, the compromises get trickier.
Am I the only one who almost spit out his coffee when reading this paragraph? I mean, building a remote home in the middle of a forest is a cool idea, sure. But then end up feeding the whole thing with 400A worth of electricity? And when the current is too high, end up supplementing with a propane generator?
Am I missing something? As a European, I'm used to way more modest figures for family homes - maybe 400V @ 25A plus gas for heating.