Whatever you do, don't try using the razor-style "hand splicers" and adhesive splice kits. Without a splicer that has a scope, you're just making bets each time that are difficult to test.
I've learned the hard way that it's just not worth it unless you can _see_ what you're working on.
I know a little about fiber connectors, and the different connector modules for speed, but I am not really sure what I need for a splicer for fiber.
Fusion splicing will still be 0.01db or better, but you will be well within the power budget of any transceiver you find with mechanical connectors, if we are talking home networking - even a 2km 10gb transceiver that is 20 bucks has a 6db power budget.
Heck, the 10km are cheaper than 2km at this point - 17bucks on amazon, power budget of 16db.
https://www.amazon.com/dp/B0CW2HGVT2?ref_=ppx_hzsearch_conn_...
A straight cable has an infinite radius, the more bend the smaller the radius
There was an encoding mechanism proposed about 10-15 years ago that used spirally polarized light to carry more channels, but it required the surface of the fiber to be polished to a much higher degree than existing cables in order for the light to go around bends properly.
that depends on the weather and frequency among other things
This is 100% wrong.
This is well standardized. As I posted elsewhere:
G.657A1/B1 = 10mm (half an inch)
G.657A2/B2 = 7.5mm (a little over a quarter inch)
G.657A3/B3 = 2.5mm (less than 1/8th of an inch)
The only cable you will find with a 6 inch bend radius is going to be armored interlocking fiber cable or something.
You can take 2mm G657.A3 fiber cable, wrap it around a pencil, and it will work 100% fine.
Even old G652 cable only had a 1 inch bend radius.
Part number: LTP12B024
I am running a project where the low voltage contractor is pulling this fiber cable into a conduit my electricians are installing.
I don’t doubt your bend radius claims on the fiber optic cables you listed, but there are far more types of fiber cable than the ones you listed.
You are confusing the cable jacket with the fiber cable inside of it. This is the spec on the jacket they use and they didn't design this particular jacket to be flexible enough to survive flexing at the level the fiber cable inside of it can. Sure - not all jackets can be bent as much as the fiber. Some because they are not made to be as flexible (as here), some because it's basically impossible (armored interlocking jackets), etc.
I'm not sure what this changes?
The part number with suffix AB0403 (the SMF A1 fiber), if you cut the jacket, you should be able to bend the fiber cable inside at a radius of 10mm and have it be fine. It appears to be standard G.657A1 fiber cable inside.
There are really not far more types of fiber cable than i listed, and this spec sheet definitely does nothing to support that claim, since as i said, it has A1 fiber cable inside the cable jacket that will happily support a 10mm bend radius.
BTW, as an aside, I wouldn't use this stuff - just looking at this sheet and pricing at my normal fiber distributors - it is both overpriced and underspec'ed for its price. Which seems pretty typical for leviton :)
Most 24 standard I/O plenum cable is going to be 7.8mm (this is 9.9, so 30% thicker), and have less than half that bend radius even with non-flexible OFNP rated jackets. If you are being charged more than 2 bucks a foot for it, you should consider other options.
Ahhhh, thanks for clarifying! Now I understand what you’re saying, the jacket and fibers have different bend radiuses (radii). I appreciate you taking the time to explain :) also, noted about there only being a few types of fiber, with a multitude of jackets.
I’ll let my low voltage subcontractor know about the underwhelming Leviton cable, it’s a plan and spec public job so it’s possible the Leviton rep is friends with the engineer and got their cable flat specced, wouldn’t be the first time!
I’m only responsible for the raceway, it’s a 2500’ run between two college campuses separated by a highway that runs outside for a good chunk of the distance so it’s possible the jacket is beefy and inflexible for temp resistance. I’m much more familiar with electrical conductor jackets, THHN and XHHW-2, which are PVC and XLPE, respectively.
I guess you could call it "the maximum sharpness tangency" or something like that, but that's not the standard verbiage.
Cables ain't free, duct capacity is finite and duct rental from the local incumbent is costly too... Please calculate the financial optimum of pay now vs. pay later - taking into account growth, various forms of attrition, cost of capital, opportunity costs and appetite for risk. Or everyone would be running 1152 strands cables everywhere.
But then I see that from a telco perspective and, now that I've read the article, it seems to be from a small-scale hosting perspective - entirely different economics.
> Paris downtown
Where is downtown Paris? 1/2/3 arrondissement? I never heard the term used for Paris. Mostly, it is used to describe the Wall Street area of Manhattan (NYC) as the island is relatively north-south and Wall Street is on the southern end.I always thought "downtown" and "uptown" were more like "south from X" and "north from X" where X is some reference point in context (e.g. "where I'm standing"). Turns out, it's more similar to "downwell" and "upwell", i.e. towards or away from some central point (gravity wells being spherical-ish and all).
It just so happens that for Manhattan which is the most famous uptown, all four of those indicators point in the same direction. In general I think an area would more likely be called an uptown if it met more of those criteria relative to some downtown. (And there would be correlation, wealthier residents would buy higher-elevation land.)
Australians are the ones who say CBD.
Not sure I have ever heard downtown being used to refer to part of a New Zealand city although I understand its meaning.
( https://www.etymonline.com/word/downtown : "The notion is originally literal, of suburbs built on heights around a city." )
It's the only available word for the concept in American English. I wouldn't recommend saying CBD; that would refer to cannabidiol or to marijuana in general.
Edit forgot link: https://downtownny.com/news/where-did-downtown-come-from/
> Let’s suppose that Fosdick, incoherent from distress, forgot to include the words “to the” between “down” and “town” when describing the direction in which people were fleeing. With this in mind, we can assume that Lower Manhattan is in fact the original “downtown,” as posited by Schwarzer, and that the possible Bostonian origin of the word is simply a misunderstanding.
I'm sure it's less of a problem in houses with other materials.
There’s also the problem of sometimes, video calls just stutter and seize up and it’s the internet’s fault, not the local network. But with a wired connection, I am immediately confident the problem is not in my network. With WiFi, who knows, maybe it’s my fault. I used to continuously ping the router so I could verify this, and indeed ping spikes would happen. Now with a wired connection I don’t worry about this.
But yeah if you run no latency-sensitive applications, WiFi might be fine.
I retrofit wired my house[1] about 20 years ago; I only have had a small handful of issues with it in that time (all basically mechanical fatigue of jacks). If I have speed, latency or connectivity issues, I can be reasonably sure the last thing I have to debug is the physical network.
[1] Copper, not fiber, but no runs are over 50m. Works to 10G so far. I used a Leviton residential structured wiring system (network, coax and phone at the time; the last 2 long since obsoleted). I did a lot myself since I'd done enough quality time in datacenters to be adequately proficient with low voltage Cat5. Not cheap but not extravagant.
So worth it as in apartment everyone and everything is blasting wifi. I see like 20+ SSIDs.
But seriously, I'm telco-biased, and it seems that the article has a small scale hosting... Different worlds. At small scale, sure - the bigger cable is a rounding error.
The minimum bend radius of any good fiber is way less than cat6 at this point.
G.657A1/B1 = 10mm
G.657A2/B2 = 7.5mm
G.657A3/B3= 2.5mm
CAT6 = 25mm
Flexible cat6 = 15mm.
Fiber surpassed copper for flexibility almost 2 decades ago (G.657 was introduced in 2006, but let's call it 5 years before all forms became common).
Even G.652 was only 25mm and standardized in 1984.
You could, but you might as well just use armoured fibre if you're doing that !
Some of the low core-count CSTA stuff out there these days could almost have you thinking its unarmored if you didn't know. Not at all bulky.
https://www.youtube.com/watch?v=h4wzJSInvww
the above is from 12 years ago
I've seen some g.657.b3 patch cords and work done for FTTH installs that are absolutely atrocious and yet continue to function properly.
They are all proprietary in their coatings for sure, but it's made to a standard. The only thing is that it's not guaranteed compatible with old G.652 fiber if you try to fusion splice it.
You can get G.657A3 that is, if you want.
But this is representative of A3/B3 cables for sure, and easy to get.
AT&T fiber and Google Fiber actually use this particular stuff in their standard deployments.
Under the covers, most of the glass is usually corning clearcurve zbl (OFS actually makes their own i believe, but for others, less common).
The most common consumer cable these days is G.657A2/B2, which is easily capable of what you see in the video.
As for pricing, i'm not sure what you are paying, but this particular stuff is also easy to get (for a consumer) at 20 cents a foot or less. 1000ft is usually 200 bucks or better. Their are idiots on ebay trying to sell leftovers from fiber installs, but if you go to any really fiber cable seller, that's what you'll pay.
Here are totally custom cuts of 1.6mm outer for 0.25cents/foot: https://www.fiberinstrumentsales.com/tlc-simplex-sm-clearcur...
if you want 3mm outer, it's 0.35cents/foot: https://www.fiberinstrumentsales.com/tlc-simplex-sm-clearcur...
FIS is usually expensive, too. I didn't look hard since that seemed "cheap enough" already.
You can certainly get A1/B1 cable for like 18 cents/foot instead of 20, but if your contractors are crushing cables, seems a bit penny wise, pound foolish.
I also wouldn't run simplex cable, as it doesn't make sense anymore.
As expected, 6 fiber versions of the above cables are only marginally more expensive.
Kinda insane.
Fun fact 1: When you don't have a proper OTDR fiber tester to check for breaks, you can shine a laser pointer down the fiber and see it projected out on a sheet of paper on the other end (you might have to call the person on the other end).
Fun fact 2: If the other end is plugged into a transceiver, don't look at the fiber end directly; instead, look at it through your phone camera. If all is working correctly, you should be able to see a faint purple light out of one of the strands.
P.S. always remember to roll it if no link initially :)
Let me fix that for you.
Don't look at the fiber end directly, always assume it is plugged in unless you can see the other end yourself with your own eyes.
Fibre light meters can be bought cheaply for a basic troubleshooting bag kit-out if you don't fancy splashing out on a fancy device.
Once, in the 90s, we were having intermittent network failures in our data center. I kept trying to troubleshoot it with the fluke, but the problem kept moving. When I pulled up the raised floor, I discovered that rats were eating the exterior sheath of the network cables. That was some fun troubleshooting!