An additional problem here is that the risks are different in different forms. Here, it sounds like people are approaching the technique based on their experiences and assumptions about mains electricity, or even car batteries.
2 kV is high enough voltage that arcing is a risk. Things they'll assume are insulators and safe, or even usable as protection, may be conductive through dielectric breakdown: in the case of wood, that's the whole point of the technique. Even air won't necessarily be safe if they're handling things so closely, especially if it's humid, in which case they could get breakdown at well over 1 mm. Meanwhile, GFCI/RCD is useless, because of the transformer.
I used a non contact voltmeter, and had shut off the breaker to the outlet I was working on. Little did I know that the jackass that did some previous wiring in the house had run wires from a different breaker in to this box. It was done in such a way that I didn't fully realize it could have separate live.
My palm below my thumb touched the live and neutral and gave me a pretty solid shock.
I'll definitely test every single freaking wire in a box from now on. F people who try to play electrician without knowing what they are doing!
Easiest way is to flip the mains everytime. I wouldn't trust those pencil testers though (the non-contact ones, the light ones yes).
If they are both aligned, the outlet was probably but not necessarily last worked on by a real electrician. If the screws are at odd angles, the outlet was probably but not necessarily last worked on by a DIYer.
Real electricians align the screws, as a sort of professionalism and a nod to any future electrician who might work on that outlet.
We have a joke at work that you know that an electrical engineer (and not a licensed electrician) did the wiring if it’s too neat (for example, a colleague of mine seriously has cable trays through his roof cavity)
Replacing an outlet. Shut off the 2-pole breaker for the shared-neutral circuit it was on. Outlet tester showed the outlet was off. Pull the receptacle out. Used a multimeter to test each wire contact to ground; all were 0v.
Only when I disconnected all the wires did one of them develop potential because somebody had apparently tied a neutral wire to a hot in another box, but I still don't understand the situation and had an electrician address it.
So even testing each individual wire isn't certain unless they're all hanging free, unless you make the assumption that things were wired correctly in the first place.
I'm very rarely surprised with what happens but it still happens occasionally.
For example today I was surprised when RCD tripped when I shorted ground and neutral on a circuit that was disconnected by its own breaker.
I had to think for a brief moment to understand that yeah, it's perfectly reasonable that this happened and no, I'm not in any danger.
I've got a screwdriver that incorporates a non-contact AC current sensor. Mine is a Gardner Bender SDT-354 [1] that I think I bought at Home Depot or Lowe's.
When the current sensor is turned on if you bring the tip of the screwdriver near a live AC wire an LED in the handle starts rapidly blinking and a beeper starts rapidly beeping.
It once may have saved me from a nasty shock. I have an outdoor light over the garage that is controlled by a light sensor, and the light sensor was going bad. It would turn the light on when it got dark but not turn it off in the morning. So I'd flip the breaker for that light off and then back on every morning.
When morning when I went to open the electrical panel in the garage I got a shock from the panel door. I went in and got the current sensing screwdriver and went back to the garage to see if I could get an idea of what the heck was going on.
As soon as I stepped into the garage the screwdriver started blinking and beeping. A little experimenting showed it would go off anywhere in the front half of the garage that was more than about a meter above the floor.
It turned out that the metal garage doors and the metal rails their rollers rolled on and the metal tracks the garage door openers pulled the doors on were all connected to live AC.
I got the fuck out of there and called an electrician.
What happened was that in the shed next to the garage that houses my well some critter had chewed through some of the insulation on some of the wiring for powering the well pump. I'm not sure how but that somehow made the cover and door of the electrical panel and all those metal parts of my garage door system electrified, but without stopping the well pump from receiving power.
[1] https://www.amazon.com/Circuit-Alert-Blade-Screw-Driver/dp/B...
I've been bitten enough times in software alone by things I was "sure" about, I don't take any chances when it comes to electricity.
Every one had a warning sticker saying 'non-insulating handle' on the plastic/rubber handle.
I'm not sure where they found conductive plastic, but had I known before purchase, I'd have gone with a different set.
If you would like to get into the psychology of someone like this I am a big fan of watching photonic induction: https://www.youtube.com/user/Photonvids
He is, seemingly, a power company tech from the UK who just really loves high voltage and messes with it in his home with his buddy.
Even professionals can get into accidents, moreover us uneducated plebs.
You'd be surprised at all the stuff you can get away with on a live computer. For example, did you know that AHCI (SATA) and PCIe (and thus NVMe) are both hot-pluggable and hot-swappable? ... and that you can hotswap RAM (with a cooperating motherboard and OS) and even CPUs (on multi-socket boards)?
as for ram I have tried it once and it freeze the pc, I forgot if I have another plugged in or not though.
Typically on hot swappable devices it’s been common to make the ground pins a little longer than the rest, ensuring that those will make contact first. The issue with hot swappable devices aside from a sharp initial draw is “grounding” the circuit to an IO pin before real ground is made. Most default low potential IO pins won’t enjoy taking the full load of the device while the ground plane is missing connection.
Oddly to me, many new PC BIOS ship with SATA hot swapping disabled. IDK why. You can plug the drive in it’ll spin up, but no data transfer will happen until you reboot. Safe, just ineffective. I recently had to learn this the hard way.
I think this is something the OS can override. If I remember correctly I could discover a hotplugged SATA device in Windows by using "Scan for new hardware" in the Device Manager.
That is to say, if hotplugging is disabled on your SATA controller, then the firmware won't see a new SATA drive if you plug it in while the machine is running. So, for example, you won't get a UEFI boot menu entry for it if you go to the boot override section that presents all of your storage devices.
Once the operating system takes over, that's all a moot point. Whether hot-plugging was disabled in your firmware settings or not, if the OS supports it, it will work. Both Microsoft's AHCI driver (msahci.sys) and the Linux "ahci" kernel module (or built-in) support hot-plugging.
On my Windows desktop with an Intel SATA chipset, hot-plugging a drive did cause Windows to briefly drop all other drives on that controller before re-enumerating all of them, which lead to a BSoD because one of those drives was the drive with Windows itself on it. However, this was solved by installing Intel's chipset-specific driver (Intel Rapid Storage Technology, iaStorV.sys) and tweaking the registry to have that one start at early boot instead of msahci.
(Note this will _not_ make a powersupply safe to open up)
On a dumb device where the power button is part of the actual circuit, let’s say an old radio this will work.
On a PC, the power button isn’t hooked to anything but the chipset or some micro or an upstream circuit that tries to start a micro. Which means to have any effect, that processor needs to be executing code, or needs to have enough power to start the chipset itself. Both of these are unlikely to have any effect on CPU capacitors or caps in the power supply.
I’m fairly certain this is placebo at best on a modern PC.
I have no idea if it discharges all the different voltage rails. I don't like having the fans try to spin up while I'm mucking about, and it stops that from happening.
Of course, from an equipment damage perspective, grounding yourself to the case ground is much more important than discharing the PSU capacitors.
I usually physically unplug the computer, push the power button, then open / touch the case (I'm in a humid climate).
I've never had an issue (ignorging fires, but those happened when the computers were intentionally energized).
Edit: Some PSUs have -12 +12 rails, I suppose if you were really unlucky and grabbed both at once the 24v differential could give you a zap.
Incidentally, does anyone know what the -12v rails are used for? Some kind of reference?
You can wet your fingers and get way lower, but I’ve never had anything much at 24V even when trying. At that low a voltage it may come down to frequency of the source.
Obviously your tongue gets way lower, as is 9V lickers know already.
The electrician popped open the switch plates, yanked out the old switches, clipped the wires, stripped the wires, wired up the new switches, and screwed everything back together.
It was all live (like 300 volt live), as the lights turned on (queue spark), as he wired the new switches. He was not wearing gloves. It was all barehanded.
It was quick, though. Took, like, a minute.
But it just sounds like something that is one distraction away from a bad day.
That said, it is sometimes necessary. I've replaced a circuit protective device in a live electrical panel in a commercial setting before. As you point out, avoiding distraction is a very important factor. That means no chit-chat, no-one overlooking and critiquing what you're doing, noise to a minimum, all of the tools you'll need prepared up-front, etc.
I heard from HV vets that one acquires a habit of keeping one hand in the back pocket when working on substations, industrial installations, and such. :-)
Not sure where there would be 300V for light switches/fixtures though. Some bespoke factory setup?
Well — so is an empty room, because there is no air to breathe.
Pretty much everything is dangerous in some form. You can die from excessive water ingestion. You can die falling from a bicycle.
I don't think blanket statements like yours are helpful in actually making things safer. Safety low-voltage electrical systems are designed to be safe - not perfectly safe, but comparably safe to other ambient risks of life. We can't bubble-wrap everything. There is no 100%, only a question of how many nines you want after the dot on 99%.
But regardless, the videos at issue are quite obviously not in the "99% safe" category and YouTube's behavior is egregiously inacceptable.
Thankfully there were no strikes, and after a couple of minutes the cloud had passed. Electricity is dangerous!
Electricity is dangerous. In every form. Period. Keep your fingers away from it when you don't know what you do. Household appliances can not only kill you on the mains side. Microwave transformers, flyback circuits, burner igniters, HV Car Ignition Systems...