Re:YouTube removes criticism of dangerous fractal wood burni...
by mikestew on Friday July 01, 2022 @10:17AM
(#31946716)
It obviously can be done, and I've heard folks more experienced than I say "all ya gotta do...", and I'll admit that I might have even wired a switch/outlet myself without flipping the breaker. And a pro could probably get away with it for a long time.
But it just sounds like something that is one distraction away from a bad day.
Re:YouTube removes criticism of dangerous fractal wood burni...
by aaronmdjones on Friday July 01, 2022 @10:30AM
(#31946896)
In the UK, as far as the Health & Safety Executive goes, who are the people who will be hauling you up in court if your screwups cause injury or death, they go to great lengths to discourage working live if at all possible.
That said, it is sometimes necessary. I've replaced a circuit protective device in a live electrical panel in a commercial setting before. As you point out, avoiding distraction is a very important factor. That means no chit-chat, no-one overlooking and critiquing what you're doing, noise to a minimum, all of the tools you'll need prepared up-front, etc.
Re:YouTube removes criticism of dangerous fractal wood burni...
by foobarian on Friday July 01, 2022 @10:22AM
(#31946792)
Meh, for 120V or 220V worst can happen is you get a little shock or trip the breakers. I don't bother shutting off power to household circuits either.
I heard from HV vets that one acquires a habit of keeping one hand in the back pocket when working on substations, industrial installations, and such. :-)
Not sure where there would be 300V for light switches/fixtures though. Some bespoke factory setup?
Re:YouTube removes criticism of dangerous fractal wood burni...
by ChrisMarshallNY on Friday July 01, 2022 @10:26AM
(#31946839)
The lights were using some higher voltage. The Operations Manager mentioned it to me, while the work was being done. Apparently, it's standard. Something like 320 volts (don't remember the exact number). I had not heard of it, beforehand.
Re:YouTube removes criticism of dangerous fractal wood burni...
by aaronmdjones on Friday July 01, 2022 @10:50AM
(#31947170)
230V AC is the RMS (root mean square) voltage; if you rectify it to DC, it comes out to 325V. Put another way, the /highest/ absolute potential difference between line and neutral in a 230VAC system is 325V.
The electrician popped open the switch plates, yanked out the old switches, clipped the wires, stripped the wires, wired up the new switches, and screwed everything back together.
It was all live (like 300 volt live), as the lights turned on (queue spark), as he wired the new switches. He was not wearing gloves. It was all barehanded.
It was quick, though. Took, like, a minute.