This Trump-level idiocy that is just never mentioned, even as people blame the gas burned in england on windy days as a cost of wind curtailment, when the curtailment is more a like a third of the cost. Burning gas to power people who chose not to build turbines is the other 2/3rds.
In the alternate world that is tens of billions of gas costs avoided to date and tens of billions more in future.
[1] https://www.bbc.co.uk/news/articles/c995xjxk97mo
[2] https://www.energyvoice.com/insights/energy-opinion/594763/m...
> Industry body Offshore Energy UK (OEUK) claims that more oil and gas could be extracted by 2050. However, the ‘High Case’ scenario for future production in a report for OEUK would still mean that 92% of production has already occurred.
...
> Compared to the maximum oil production that occurred in 1999, UK output in 2025 was 77% (over three-quarters) lower.
https://eciu.net/media/press-releases/around-90-of-uk-north-...
Banning onshore wind turbines was just insanity. Despite the insanity, the UK has made great steps with offshore wind, but offshore wind is expensive and has all sorts of accompanying headaches. Onshore is super cheap and quick to build per unit power by comparison.
Onshore wind turbines are going to be much more important to the future of UK energy independence than balcony solar.
I read what is happening in exactly the opposite way. To me it shows that Milliand and the government at large do very little with no strategic thinking and no plan (same as the guys before in fairness but this government was supposed to be soo different...) and, in this case, is only reacting in a panic after almost 2 years in office to the pressure of "doing something" because of the Iran war, while also being told (slight mitigating circumstances for Milliband) that it mustn't cost anything. I always picture scenes from The Thick of It/ In the Loop when I imagine how they come up with 'ideas'.
Like you just invented a story and made massive implications based on the invented story, with absolutely no hesitation. And you’re probably in at least the 50th percentile of intelligence.
This is why we’re screwed.
Of course they would because it's work being taken away from them but it would be allowing people to plug generators into ring finals with unidirectional breakers. It's not even guaranteed that the circuit is protected by anything newer than fuse wire or an MCB. No guaranteed earth leakage detection. No guaranteed surge protection. Relying on the cheapest inverters to sync frequency accurately. And
I have more faith in German standards and work ethic than our own.
So in the UK we have 2.5mm^2 wires in a ring on a 32A MCBs... Of course a 2.5mm^2 wire is rated ~20A so any issues with the ring (sockets still work since connected from the other branch) can burn the wire before the MCB trips...
From what I understand the UK allowed it because of a severe postwar copper shortage and it persists to this day because it's allowed and a bit cheaper.
I'd say "severe post-WWII money shortage". After wartime expansion, the global copper industry could physically meet peacetime demands. But the UK was very close to national bankruptcy. And the Luftwaffe had turned an awful lot of their prewar housing into rubble. So - any cost that could be cut, was.
If you plug it into an overloaded ring final (which is not uncommon in the UK - half our house's sockets are on a single ring), you have to rely on the generator being able to detect faults to protect that circuit.
You could also overload that circuit's wiring. If you have a a 16A Ecoflow, plug it into a 32A ring, you could draw 48A before tripping the grid circuit breaker, potentially causing significant heat in the wires. Dinky 3A generators won't do that but I don't think they're the limit our government are talking about.
It isn't as if electric charge coming from balcony solar panels is some new magical-seeming type of electricity.
Also, why do wires have to be fixed to joists every 300 mm? It's not about the electrons.
Not to mention that most houses aren't up to current electrical standards, much less fire codes.
However in the case of a UK home, where you may have a single ring circuit connecting all the sockets on the whole floor, what's in the breaker panel isn't going to protect you with plug-in solar anyway. Better hope what you are plugging in meets UK standards and isn't just some Chinese rubbish that claims it does.
After some research the main reason seems to be two-fold:
Answer #1: Many UK RCDs/RCBOs are actually single-pole devices and don't disconnect the neutral. In the simplest case, this means pressing the test button might burn out the test resistor when backfed. I don't imagine this to be a problem in practice, since grid-tie inverters shut down very quickly if the grid disappears under them, especially plug-in inverters. RCDs/RCBOs elsewhere are virtually always disconnecting the neutral, so don't care about this.
Answer #2: It looks like some/many one-module wide UK RCBOs _do have_ electronics in them, even if type A, because they're actively driving the trip solenoid of the MCB part, and if you sketch this out and do it in a very cheap way it's easy to see how you could burn that out if backfed (i.e. powering the trip solenoid during a fault is assumed to disconnect in a very short amount of time, but if backfed for longer than the disconnect time that might be enough to toast the solenoid or the driver).
Notably neither of these has anything to do with the direction of power flow.
This is not correct; all type AC and type A RCDs used in British consumer units disconnect the neutral as well. Some RCBOs do not disconnect the neutral and this is a problem in some circumstances. The datasheet I linked for Wylex NHXS1 RCBOs explains that these ones do disconnect the neutral.
> Answer #2: It looks like some/many one-module wide UK RCBOs _do have_ electronics in them [...] but if backfed for longer than the disconnect time that might be enough to toast the solenoid or the driver
This is correct. For an example of this construction in an RCBO, see [1]. This illustrates that if the supply is connected to the "To Load" part of the schematic (toward the end of the video), as it would be if the supply is a solar PV inverter with battery storage, then it can continue powering the electronics and be shunted out by the thyristor after it has supposed to have tripped, very quickly burning itself out.
Bidirectional RCBOs are not designed in this manner. They have more complicated circuitry that makes them more expensive to manufacture, but are absolutely required in situations like this if you don't want your protective devices to burn and/or explode when they operate.
> Notably neither of these has anything to do with the direction of power flow.
Yes it does, because if the power is flowing backwards to how they designed it, that is backfeeding it, keeping its circuitry powered after it should have been disconnected.
But that's rather the point here that consumers are the ones who are going to be plugging in these devices, with no appreciation for their circuits and safety devices. The only code that matters is the last version of it adhered to when their home was last wired. In extremes, that can be 40 years or more.
The conventional practice in the US is still to use GFCI receptacles rather than breakers.
If the circuit will be supplying power too (e.g. battery storage, an EV and EVSE that supports powering the house from the EV, etc) then you need a bidirectional RCBO.
People with no differential fault protection need not worry about any of this, they'll just be killed when it goes badly wrong.
Source: Am a UK electrician
Example: https://assets.cef.co.uk/downloads/pdg/wylex_nhxs1b32_datash...
EDIT: To say nothing of people with unidirectional electricity meters; plugging these into those setups will get them prosecuted for electricity theft. All SMETS 2 smart meters are bidirectional; you'd best check your meter if it isn't one of those.
Pre-smart non-prepayment electronic meters (for those with old meters, still submitting manual readings, and paying by direct debit) will be fine. Most of these meters, and all smart meters, are inherently bidirectional, because they maintain 4 counts (energy imported and energy exported, in kWh and kVARh) and your energy provider will do all the necessary math to figure out what to actually bill you for (residential customers are not billed for kVARh usage).
The UK government in 2011 announced plans to have 50 million smart meters installed by the end of 2020. In typical overpromise underdeliver government fashion, they didn't even achieve half of that; by then, only 23.6 million had been installed, and of those, 4.5 million had stopped working because they were initially (and stupidly) designed to be tied to a specific energy provider and the customer had changed provider. This even affected me.
Nevertheless they'd still accurately track energy consumption and export even if they'd lost their reporting capability, so you have nothing to fear here. This situation has been rectified at the redesign stage with provider-independent SMETS 2 meters, and all SMETS 1 meters still in service have been hotpatched to bring them into line (restoring their smart functionality regardless of provider).
Even today (well, as of last September), this number is only 40 million, with only 36.7 million of them actually working as designed (reporting readings automatically).
This leaves up to 16 million properties with a meter that may stop working and expose you to a theft investigation when you obtain generation capacity that even momentarily exceeds your usage (for example if you have a dual RCD board and one of the RCDs trips, taking out half of the circuits in your home, but not the one the inverter is plugged into).
Realistically the true figure is probably around a quarter of that; prepayment meters were very popular among the renting population of the time, and those who wanted to track their energy usage carefully and only pay for it with cash as and when needed, and sometimes people had these meters forced upon them by suppliers after the customer had demonstrated poor payment history, but they were far from the norm.
Average home owner buying plug-in solar at a supermarket isn't going to know or care about any of this. They'll just plug it in, and it will work, until one day maybe it doesn't and their supplier opens a theft investigation.
So if you spent a week with the meter connected normally, then you swapped the input and output cables around for a week, the meter would be back at zero. Free electricity!
They used anti-tamper seals to make it more detectable, but there are ways around that sort of thing.
https://www.digikey.com/en/articles/anti-islanding-and-smart...
question is whether the ones allowed for sale implement it well and are tested for it
You have 4 neighbors, all with grid-tied inverters, all of which will do rapid shutdown if the grid goes down.
The grid does go down ... but are there circumstances under which the presence of neighboring inverters will "hide" the grid being down from each inverter, and so they will keep delivering power back to the grid ?
Consider 100 homes on a power line network and the breaker trips. They probably draw 50kW on average, more if it's hot or cold and AC is on. Unless there's enough power generation available to power that entire load, voltage will drop and any halfway reasonable hardware should give up.
What do you mean by "guaranteed surge protection"? Are you an electrician to write like that?
And it is of course home-counties obsessed thinking. They can both afford these toys and also have more sun
Government press release with a long list of pull quotes: https://www.gov.uk/government/news/government-to-make-plug-i...
(I note that in the alternate universe where Ed Miliband became PM because he didn't eat a bacon sandwich, we could have had this a decade ago. It is embarrassing to be beaten on environmentalist regulatory efficiency by Germany)