Re:Suddenly energy independence feels practical:Europeans bu... by hamdingers on Friday March 27, 2026 @05:08PM (#47548272)
Not in the US, but in parts of Europe they effectively use AFCI/GFCI breakers for everything.
Re:Suddenly energy independence feels practical:Europeans bu... by bluGill on Friday March 27, 2026 @06:10PM (#47549023)
Those are code in the us now too. (with exceptions for where they don't make sense)
Re:Suddenly energy independence feels practical:Europeans bu... by oliwarner on Friday March 27, 2026 @08:21PM (#47550146)
Always important to note that "code" does not mean "must meet this standard". Many existing installations will not meet current code and there are varying levels of code (at least in the UK) that mean anything from an electrician can ignore minor faults through to network-notifiable issues.

But that's rather the point here that consumers are the ones who are going to be plugging in these devices, with no appreciation for their circuits and safety devices. The only code that matters is the last version of it adhered to when their home was last wired. In extremes, that can be 40 years or more.

Re:Suddenly energy independence feels practical:Europeans bu... by bluGill on Friday March 27, 2026 @10:44PM (#47551036)
sure, but everything new must meet current code. nobody upgrads when code changes anywhere. Codes from 40 years ago were not bad, though things are always improving.
Re:Suddenly energy independence feels practical:Europeans bu... by hamdingers on Friday March 27, 2026 @10:14PM (#47550858)
NEC doesn't specify GFCI breakers, it merely requires receptacles in certain areas have GFCI protection, and accepts GFCI breakers as one way to provide that.

The conventional practice in the US is still to use GFCI receptacles rather than breakers.

Re:Suddenly energy independence feels practical:Europeans bu... by bluGill on Friday March 27, 2026 @10:42PM (#47551027)
Right, but the NEC spec arc fault as well (i've only seen this on breakers). recepticals are cheaper and otherwise just as good.
Re:Suddenly energy independence feels practical:Europeans bu... by conk on Friday March 27, 2026 @11:49PM (#47551441)
Because NEC 210.12 requires all devices to be protected. Which means if you have a switch or splice before a plug the only way to protect those is with an AFCI breaker. The only exception is a continuous run from the breaker to an outlet in metal conduit or MC cable. Given how much is romex this effectively forces AFCI branch breakers.
Re:Suddenly energy independence feels practical:Europeans bu... by sgc on Saturday March 28, 2026 @01:15AM (#47551856)
I find that receptacles tend to break prematurely if they are wet locations, even if 'protected' with a weatherproof box etc. You also need to know where the receptacle is and make sure it is accessible instead of behind a piece of furniture etc. Then some electricians misunderstand and put receptacles throughout the run (much more expensive than one breaker which is about 2x a receptacle), and in edge cases you need to know the order in which to reset them to get things working again. I much prefer to just have everything in the panel.
Re:Suddenly energy independence feels practical:Europeans bu... by SoftTalker on Friday March 27, 2026 @10:12PM (#47550850)
They are terrible for anything motorized though. The one in my bathroom trips every time I turn off the vent fan.
Re:Suddenly energy independence feels practical:Europeans bu... by stephen_g on Saturday March 28, 2026 @06:53AM (#47553419)
What tripping curve do your RCDs have? That is not normal if they are the right type, really sounds like something is wrong!