They have all the data available on their end, as far as I can tell! (Unless DOCSIS modems somehow don't have a standard "signal receive report" functionality?)
Here's a 1960s vintage Automatic Electric line insulation test system at work in a step-by-step central ofice. [1] Here's the manual for automatic line insulation testing in a 5ESS switch.[2] 5ESS is still the major AT&T switch for copper analog phone lines. After that, it's all packet switching.
For fiber, of course, moisture doesn't affect the signal.
This led to an urban legend: "bell tap". While Western Electric phones were designed to not react to the ALIT test signal, many cheap phones would emit some sound from the "ringer" when the 400V pulses came through, some time before dawn.
[1] https://www.youtube.com/watch?v=Wt1GGdDa5jQ
[2] https://www.manualslib.com/manual/2755956/Lucent-Technologie...
(I've sent a quick email suggesting it be added to https://news.ycombinator.com/highlights :)
If you have to build reliable distributed systems, it's worth understanding how this was done in the electromechanical era of telephony, where the component reliability was much worse than the system reliability. "Number 5 Crossbar"[1] is worth reading, but hard to follow if you have no idea how telephone switching worked and are unfamiliar with the terminology.
Number 5 Crossbar, in current terms, was a collection of microservices. There was a big, dumb switch fabric, and "markers" which told it what to connect. Other microservices included trunks, originating registers (which listen to incoming dial digits), senders (which sent dial digits to the next switch), billing punches (which recorded toll call data for later billing), translators (which held routing tables), and trouble recorders (which logged errors.) Central offices had at least two of each resource, for redundancy. Resources were "seized" as needed from resource pools, with a hardware timeout and alarms to prevent resource lockup. If something went wrong in setting up a call, it was retried once, using different resources. If it failed on the second try, the caller got a fast busy and there was an alarm and a trouble recorder dropped a trouble card. Markers did not have persistent state. They started each call with a reset. So they could not get stuck in a bad state.
In the entire history of the Bell System, no electromechanical switching office was ever down for more than 30 minutes for any reason other than a natural disaster or a fire. It's worth understanding how they did that.
[1] https://telephoneworld.org/mdocs-posts/number-5-crossbar-sys...
Maybe because you know that someone spent a lot of time on it before it was published since no adjustments could be made after the fact.
This feels like a term a sci-fi author would invent in an alternate history setting to replace "error log" and I find it very humorous.
The previous version was a panel of blinking lights called the "trouble indicator". When an alarm sounded, someone had to go to the panel and record by hand which lights were on. There were about 200 lights. So the trouble recorder, which recorded that info automatically, was added in larger central offices as an upgrade.[1]
[1] https://hackaday.com/2022/12/02/stack-trace-from-the-1950s-p...
At 02:40.
And yes, it is an adding machine.
But every evening, mostly around 21:00 or so, the phone gives a gentle "peep" without then ringing.
I wonder if it's a line test?
There are various weird, obsolete signals in analog phones. Ring pulse alerting signal. ALIT test. Polarity reversal. Ring to ground. Ground start. Caller ID (1200 baud FSK between the first and second rings) DSL. Basic talk and ring was standardized around 1900, and everything else is backwards compatible. Ringers are supposed to ignore all that stuff. People who implement Asterisk PBXs are into this.
Here are some actual waveforms, if anybody cares.[1]
[1] http://www.adventinstruments.com/Products/AI-5120/Screenshot...
It might happen that an equipment manufacturer sees an opportunity and builds something, but then they have to go into a long sales cycles to convince operators to use it. Operators are in a duopoly situation in most places, so quality of service is kind of a secondary concern for them - customers may get annoyed, but as long as the competition is not vastly superior, few actually switch. It is not a market prone to innovation.
The other common denominator was the cable company refusing to believe it was an issue with their equipment; this meant it took a couple of months of calling them every night until they finally sent a technician and a manager to my house to verify that I wasn't wrong, leaving my house, coming back 15 minutes later to say "it'll be fixed tomorrow, there's a problem with the LE balance up the road" - and then the issue is resolved.
Now this doesn't sound so bad, until you learn that the first time this happened to me, i had only VoIP - so the internet would start to foul, i'd call the cable company, and the tier 1 would reset my modem at some point, and then i wouldn't be able to call back until after midnight (or whatever), when there was no longer a problem. So after a week of this, i would walk 30 minutes - one way - to a pay phone (remember those?) once the internet slowed, call them, explain that i couldn't do anything they wanted me to do physically, since they disconnected my phone line every time i called.
This is what happens with a de facto monopoly.
I will never pay suddenlink another dime, even if they're the only terrestrial provider, for whatever reason.
Maybe there should always be a hidden option that only people that meet a certain troubleshooting ability threshold get access to when calling in for tech support….
I'm guessing that these scripts that we're all complaining about solve 95% of problems customers call in about. Sure makes things painful for the 5% of cases, though.
I've been a (grudging) Comcast customer for ~17 years, and I have been impressed by how their monitoring has improved over that time. It's been quite a number of years since I've had to convince them that I had an actual problem that their systems didn't automatically detect.
Almost every day, in the heat of summer, I get one to five 10-minute outages as soon as the temp gets over about 80F. More when it’s hotter, usually. Usually it results in a modem reset, so it’s hard to tell how long the actual outage is.
Been happening for going on 5 years. They replaced the under-street cable from our house to the junction box across the street to no effect. I suspect it’s that junction box, but afaict, none of my neighbors that share that junction box have the same issue. Not very fun to have your WFH day collapse unexpectedly in the middle of the afternoon.
Strangely, for the last month we’ve had several days of 80+ temps with no sign of outage. So fun.
If you can, try forcing a level at/below the speed you get during the breakage and see if it just rides it out. If it does, shift it back up and plan your coffee breaks around it. Or don't, I'm not your mother
I've experienced something similar except for temperatures below ~32-36 degrees. At this particular location it would result in a ~1hr outage going below that temperature, but not when it went back above it for some reason.
I wonder if the coupler’s center conductor contacts could be expanding just enough to break the connection?
Tech showed up around noon, saw I was indeed having a bad connection, went and checked the signal at the junction box for the street (can't remember what you call these) and everything was normal there, so he closed it back up again and double checks the signal at the house again, but it was fine. He walks the lines to double check but everything looked normal.
His best guess was that moisture was condensing ever so slightly inside the junction box that morning, and was let out as soon as he opened it at around noon, which fixed the problem.
Eventually I called so many times and had so many appointments, that the tech lead gave me his direct number and told me to call him directly the next time it happened. When it did, I did, and he ran some tests, and confirmed there was a problem. I don't know that we ever got it sorted out (it was a while ago), but just getting them to agree there was an issue took a very long process.
A customer's DSL connection dysfunction's frequency increased mornings and evenings. Culprit: the lift's electric motor leaking EM all over the place.
A bunch of DSL connections degrade when traffic increase... Crosstalk in big cables of course !
The sort of fun incidents that take a good while to troubleshoot... I'm glad we are migrating away from DSL to fiber: either it works or not !
Called the cable company, tech came out. Everything inside was fine, but the cable from the main line to the house had a tiny cut in one spot, not enough to really affect the connection, but enough for ambient moisture to work its way in and foul the connection.