> Now you can connect as many microinverter-batteries as you like in parallel, using #14 wire, to one ordinary circuit breaker per battery plus (depending on the overall arrangement) one big breaker to protect the common bus.
You can build it right now. AC coupled batteries exist; here is some random one that scales up: https://www.fortresspower.com/ac-coupled/
The problem is that you generally want batteries when you want renewables and in that case just having one big box handling batteries and solar panels is more economical than microinverters everywhere
48V battery pack + BMS is significantly cheaper than same thing with microinverter, and when you scale up one big inverter is cheaper than a bunch of smaller ones.
So yeah, it is "best" but also most expensive way. And frankly, the hardest to develop, which is probably why there is little to no open designs for that.
And here I am mad that home-storage server rack batteries are all 48V it seems, but for the same reasons (huge 400+ amp cables required to get decent wattages). When each car charger can do ~14.4kw you need a lot of fat cables running to battery banks
Only above 1000V RMS AC or 1500 V DC is considered 'high voltage'.
That's why a correct sticker on domestic equipment will usually use the wording 'Dangerous voltage' or 'Hazardous voltage' or the like, not 'high voltage'. An actual correctly placed 'Danger - High Voltage' sign tends to mean something like 11kV AC
12v is a miserable voltage to work with in general: too high for most logic circuits and for LDOs to work effectively but it’s too low for any large load with high-power applications become cost prohibitive quickly due to the cost of the conductors. Fun fact: Auto makers have gotten away with under sizing starter conductors, despite it drawing 80-100A, because it is only energized briefly and the length of the run is very short.
https://www.allaboutcircuits.com/textbook/direct-current/chp...
We're running out of copper. So better keep your voltages on the high end (but still safe of course).
https://www.cnbc.com/2023/02/07/there-isnt-enough-copper-in-...
> Oh, and in case you’re wondering, I have no idea why women tend to be more susceptible to electric currents than men!
The pain thresholds are given in a table that is split by men and women. I believe the assumption is different conductivity between “typical” male/female bodies, but it’s really not spelled out.
https://www.ncbi.nlm.nih.gov/books/NBK218162/
However, men are typically larger, so perhaps that's the reason.
US NEMA/NEC is a very different standard.
Note that simply voltage/frequency alone can communicate everything necessary to evenly distribute load. For example:
Output frequency = 60 + X Hz
Where X varies between -0.1 and 0.1, indicating the percentage of max load the inverter is under(in charge or discharge direction).
Such a scheme will self synchronize any number of inverters, even of varying capacities, into a stable grid, and they will all be the same percentage loaded. The grid can have a few dumb gas generators on too and remain stable. No fancy comms needed.
Also, can a pure frequency-based scheme handle the case where a whole bunch of inverters are in parallel and a load that’s much larger than any one of them can handle individually starts up?
The scheme as presented keeps the inverters under equal fraction load, but does not guarantee the batteries end up at equal state of charge. The formula can easily be modified to over time achieve this too:
X = 60 + (fraction load of inverter)*0.1 + per_battery_factor
The per_battery_factor would be set based on the batteries state of charge and/or any user instructions from buttons to charge or discharge a specific battery.
Yes, but with caveats... The grid will startup, smoothly (ie. gradually), but during startup every inverter will be at its maximum configured load (with the maximum load config ramped during startup). When the maximum load is hit, the frequency sits at the minimum design frequency (59.9 Hz in this case), and voltage drops instead.
So your large device will see a sine wave at 59.9 Hz that starts at zero volts, and increases in amplitude to 230 volts gradually over many seconds, and as soon as it hits 230 volts, the frequency will almost immediately become 60 Hz.
For large motors, thats a problem. Large motors typically don't like line frequency at a reduced voltage - they can end up not having enough torque to turn, and will just rapidly heat up. They would do better without the gradual startup ramp - but that startup ramp is necessary to ensure the inverters stay in sync.
Yep, inverters can easily read the frequency change to adapt their output. But a device that reads the network load and translates it into a frequency change is really not trivial. Grids do this because mechanical generators do that translation, but the easiest way to add it to a non-mechanical grid is adding a mechanical device.
Lines exclusively fed by inverters will naturally get undervoltage, instead of frequency shifts.
Nah - it's pretty simple. Have your inverter measure it's own load - for example by measuring the current through the main switching element. Compare that to the max current that switching element can handle. That is your percentage load that you are under. (negative if current goes backwards)
Then use that to decide what frequency you will output, using the formula.
There is one extra element to this... At startup, to avoid large transient currents, you need to start with the 'max switching element current' for the formula at zero, and then increase it smoothly only while the calculated load figure is under 100%. Within a few seconds you will get sync with any existing network. Such a scheme also works for blackstarting an isolated grid, or with many other inverters with the same strategy.
This scheme has a big benefit that there is no need to measure the grid frequency precisely - which is actually a fairly hard thing to do on noisy small grids.
And it turns out thats all thats required to maintain grid sync. As long as supply capacity exceeds demand at all times, this grid will be stable.
Reconnecting two grids at differing frequencies is hard.
Indeed it is. The last time this happened in 2021 here in Europe, South-Eastern Europe split off, and it took a good hour to get everything balanced again [1].
[1] https://www.entsoe.eu/news/2021/01/26/system-separation-in-t...
That's not the main reason.
The main reason is that if grid is down, workers need to work on it safely and so they need it de-energized, not some random solar installation trying to feed power into it.
Some inverters for that reason have 2 outputs, one for grid, other one for so called EPS (emergency power supply). When grid goes down, usually relay disconnects the two and inverter only feeds power to EPS, and re-connects both outputs only when grid is back up and synced. So you'd shove your important loads onto EPS output and have it grid-independent.
I’m sure this has motivated someone who makes rules, but I once had occasion to ask some actual line workers replacing equipment serving me, and they laughed. They said that they always assumed the lines were hot at both ends, and if they needed a line to be de-energized for safety, they would deliberately short it out. A pesky little residential inverter was not in the slightest bit concerning to them, anti-islanding or no.
I do believe that closing a switch between the grid and a small residential island could be unpleasant for the island or maybe even for the switch. And closing a large switch connecting an entire neighborhood that somehow formed a functional island and connecting it to the grid without synchronization might genuinely go poorly.
But mostly I think the most important current reason for anti-islanding is that a small residential or light commercial inverter is unlikely to have anywhere near the capacity to power an entire secondary circuit, nor does its owner want it to.
> I’m sure this has motivated someone who makes rules, but I once had occasion to ask some actual line workers replacing equipment serving me, and they laughed. They said that they always assumed the lines were hot at both ends, and if they needed a line to be de-energized for safety, they would deliberately short it out. A pesky little residential inverter was not in the slightest bit concerning to them, anti-islanding or no.
Well, that's generally good safety measure.
> But mostly I think the most important current reason for anti-islanding is that a small residential or light commercial inverter is unlikely to have anywhere near the capacity to power an entire secondary circuit, nor does its owner want it to.
Many places do, hell, common problem is grid voltage being too high and inverters turning off because too many neighbours got solar. I'd imagine its pretty easy in peak to have solar exceed local demand even if only part of houses have it. At the very least "to the next transformer".
I wonder whether the move to green energy would change the way grids are build. "Micro-grid" with all houses on street connected to substation with a bunch of batteries that most of the time just stores local peak and sells it back to the residents might be an interesting idea and potentially make grid more resilient overall.
An old electrician once showed me his technique for tracing a circuit in a house back to the breaker panel: open the box, expose two wires, cross them with the shaft of a screwdriver, wait for the pop, walk back to the panel and see which breaker tripped. Tada!
If I followed this right, the frequency goes up with load (which seems backwards). So a 50%-loaded grid will be at 60.05 Hz. A newly started inverter will try to output 60 Hz (and fail, since it is unable to single-handedly reduce the frequency). But it will surely end up with nonzero current.
Don’t real spinning synchronous machines work the other way? If they are overloaded, they spin slower, and if they are spinning a bit slower than the grid when connected, the grid will speed them up?
Old car stereo trick, to power big amplifiers in the trunk: use a second battery and big power lead to it, small power leads from the main battery to the secondary. That secondary can be backed or replaced by big capacitors, too; with commensurate increases in cost and possible risks when things go wrongs. But you can provide rich chunky amps and use skinnier cable than you'd think on the long run to do it.
- you don't want a permanent connection between the main and aux battery to avoid accidentally sucking both batteries dry on the aux-battery side, and to avoid the starter overloading the cable between the two batteries
- you don't want to risk an empty aux battery charging itself on the main battery and engine with more current than the cable supports, hence the fuse
- you do want to be able to connect both batteries in a scenario where you accidentally drained the main battery (e.g. a light left on) to "self-start"
For GPUs and any USB PD connections ('standard' is up to 20V 5A while 'extended' is 48V 5A) a system power level of ~48v might be very useful. It would also give a chance to replace the recent higher density connectors that aren't designed with a sufficiently robust user experience with improved versions that more clearly lock into solid connection.
Pretty much the only PC part which wants native 12V would be the fans. All the other parts drop it down to 5V / 3V3 for auxiliary components, or 1-2V for the CPU and GPU cores - which use the vast majority of power.
Dropping 12V DC to 1.5V is reasonably doable, but dropping 48V DC to 1.5V is a bit of a pain. In general you do not want to go beyond a 1:10 ratio for efficiency reasons, so 48V doesn't really gain you anything, while at the same time resulting in a massive compatibility break.
The push to 12VO is driven by a desire to get rid of technical debt. The 3V3 / 5V wires can't handle the current you need on those rails, so those are converted from 12V anyways. And literally nobody is using the -12V and -5V wires, so keeping those around is pointless.
There are iirc GaN devices from epc-co these days that make it feasible to go directly from 48V with the VRMs to the 0.5~1.5V for the core.
1 kW at 100V or 250V or similar uses a nice, small, flexible wire. It can be quite safe because it can be fused or otherwise protected at low currents, which mitigates the risk of welding things, starting fires, or arcing. Ground fault protection, arc fault protection, and general loss-of-isolation protection are available. It’s easy to rework (lever nuts! screw terminals!).
400A (or even 80A or so like in this article) is a whole different ball game. Sure, you have to work hard to electrocute yourself. But you can easily set things on fire or weld things together without coming close to blowing a fuse. And you need to protect both ends of wires in a parallel arrangement. And the wires are enormous, expensive, and hard to terminate.
I would much prefer one of three alternative designs to become popular:
1A: a series arrangement of batteries at a civilized 48V or so. You can do this with an aftermarket BMS, but they tend to be janky.
1B: same but actually high voltage (a few hundred V, like an EV)
2: batteries with microinverters and a civilized way to share current. A manufacturer could make a single package with a 1kWh battery, a BMS, a low voltage, low current DC auxiliary output, and a ground-fault and overcurrent-protected 110-250V AC input/output. And an RS485 or 10BASE-T1S or CAN connection so that they can coordinate their I-V characteristics to appropriate distribute charge or discharge current.
Now you can connect as many microinverter-batteries as you like in parallel, using #14 wire, to one ordinary circuit breaker per battery plus (depending on the overall arrangement) one big breaker to protect the common bus.
edit: Also, with this design, no one, not even the manufacturer, needs to touch a heavy-gauge wire. Everything in the battery would use cheap, painless busbars or small wires, depending on the internal voltage, and the manufacturer could set the voltage however they like. Although 12V internally might be entirely reasonable if the end user also wants to consume 12V at very low currents through the aux output.