Re:1000W 12V –> 220V Inverter by gaudat on Wednesday May 31, 2023 @08:01PM (#36146122)
And I think 48VDC is the highest convenient voltage you get before exceeding ELV. There are a lot of surplus telecom and server power supplies that gives 48V at decent current. Above that there is a real risk of electrical injury, at least according to regulations.
Re:1000W 12V –> 220V Inverter by samtho on Thursday June 01, 2023 @12:20AM (#36147531)
You can actually go up to 120VDC (with no ripple) before you’re out of ELV - which I always find surprising. You’re probably thinking of the A/C limit which is 50V RMS.
Re:1000W 12V –> 220V Inverter by gaudat on Thursday June 01, 2023 @12:31AM (#36147586)
Interesting, I thought the limit is at 60VDC.
Re:1000W 12V –> 220V Inverter by omegabravo on Thursday June 01, 2023 @02:15AM (#36148063)
IEC limits are 120VDC, 50VAC which quite a few countries will use (eu*/au/nz).

US NEMA/NEC is a very different standard.

Re:1000W 12V –> 220V Inverter by auxym on Thursday June 01, 2023 @07:43AM (#36149860)
60 VDC / 30 VAC in Canada per CSA Z462 (workplace electrical safety).