There are what? I can't imagine what a single-family home would do with 50kW of power.
I certainly would not be. What's the saying about a fool and their money?
Your average European SFH has anything from 25-50 kW of heating power for heating and warm water plus 22 kW of electrical load (3x32A @ 230V). Easy enough to do with natural gas or oil, but if you want to switch towards electricity as energy source with all the wars going on... you now need a whole lot of electrical generation capability to survive an outage in the winter, even with heat pumps.
(Don't get me started on the French, these fools need so many NPPs because they run straight resistive electrical heaters, what a waste compared to heat pumps)
I heat my house + provide hot water with a heat pump of 6 kW output. I do everything with electricity; before we had an EV and solar panels my yearly electricity consumption was something like 3400 kWh. Granted, that is with a very well insulated house and definitely below average but still, average houses here don't need anywhere close to 50 kW. You can't even get such a connection to the grid as a residential user; a standard connection is ~16kW although you can request a bit more.
Yeah but most homes in Germany (or, while we're at it, in France) aren't. As a result, we pay through our nose for oil and gas, and the French have to cross-fund EdF with its NPP boondoggles that explode in budget and come decades late.
> You can't even get such a connection to the grid as a residential user; a standard connection is ~16kW although you can request a bit more.
Huh what? 16 kW is about 3x20 amps, that's rare to see even for apartments these days. Standard I've seen in Bavaria for apartments is 3x25, SFH is 3x40 amps, some 3x50, and if it's a former farm site, 63, 80 or even 100 amps.
Though installing a soft start goes a long way to helping reduce that need, regardless of which technology is used.
I have a transformer that serves only my shop :)
I use 800 amps of single phase inverted into 200 amps of 480v 3 phase (the rest of the single phase is for the house and apartment above the shop)
I have 200kwh of battery as well.
This is definitely on the extreme side, but most woodworkers (and metalworkers) i know use 50kw total easily within their single family home garages. Once you get past portable tools, they really don't make tools with less than a 5hp motor because it would be more expensive and annoying.
Unless you have employees (and at that point, not really a house but business), how ?
Wood is not like this.
As for how much at once - the wood cnc is about the worst case: 6KW in servo motors and other electronics, 10KW spindle, 10KW vacuum pump, 5kw dust collector, all running at the same time. So 30-35kw at once, easy. The vacuum pump is holding down the pieces, and would normally be 20-30kw alone, i just have a remarkably efficient one - It's a VFD rotary screw vacuum pump, which is about as efficient as it gets. Most people use 40hp blower motors to achieve the same CFM@HG i get, rather than this setup, and that is about 30kw. Being more efficient is remarkably more expensive.
In US/CA your feed is 240V (L1-L2-N) and a 200A service is standard on homes built in the last ~20 years: 240V*200A = 48000W (48kW).
During the heat wave over the summer my AC was using about 4kW of power on its own, and that's just the compressor outside.
That's often on start-up. I'm in an older Canadian house with 'only' a 100A service, and when the external AC unit kicks on there's often a flicker to lights.
It might not be a bad idea for me to install a soft start device (which would also probably help with unit longevity):
* https://www.microair.net/collections/easystart-soft-starters
You can find various before/after videos about them being installed and the drop in in-rush current.
Its usually pretty common to hit anywhere between 60-80% RLA during a normal summer day.
The house was built in the 1890s before electricity was even "invented": there are (disconnected) vestiges of knob-and-tube wiring, and gas lighting pipes before that.
In a modern system the hot, neutral, and ground are all running in the same jacket (like Romex) or conduit. Topology is consistent for all wires in the system.
In a knob and tube system, each wire is individually wired inside the wall cavities. So it's often the case that a neutral wire might feed one set of outlets on one leg of the split, then go on to feed another set of outlets on another leg of the split whose hot wire runs a different route. In fact, that's kind of the whole point of K&T: keep the neutral and the hot away from each other as much as possible because insulation (at the time) was unreliable and shorted wires cause fires. And definitely keep the two hot legs even further away from each other if you can.
Even with perfect topology of a modern system, consider what happens when you are running a 10A appliance on one leg. 10A is flowing through the hot, and another 10A through the neutral.
Now what happens if we turn on 10A on the other leg of the split? 10A flows through hot A, 10 amps flows through hot B, and ZERO amps flow through the neutral because the loads are balanced.
If you turn on a device that has high reactance, like a vacuum cleaner motor has a lot of inrush current, then it can cause lights on the other 120V leg to get an unstable current while the electricity finds its way through the new load instead of the neutral, but then not so much current is needed after the inrush, so it has to find its way back to the neutral.
Now, imagine the neutral topology isn't consistent with the hot, as in K&T wiring. It exacerbates the problem.
Plus, no matter what you do let's say your maximum service ampacity is 200A and you have a balanced 240V load like a permanent A/C. The inrush current can cause the entire rest of the house to brown out for that moment as the incoming service simply cannot deliver that many amps without a significant voltage drop.
That said, it's the unbalanced 120V loads like refrigerators, portable A/Cs, and vacuum cleaners that really cause the flicker, especially in a K&T wired home.
Questo perché hanno case mal isolate, troppo grandi e usano condizionatori a tecnologia obsoleta, senza inverter, che possono solo funzionare a 100% (e se gli va bene hanno un secondo stage a 50%).
Lots of time of the yeary system runs almost exclusively it's second stage. An inverter unit wouldn't do much for me but increase my upfrontcosts considerably while reducing reliability. The way the climate is here, a two stage unit is plenty of variability. It doesn't take long for the heat to set in. You go from not needing any AC to wanting to crank it pretty quick.
The lack of an inverter means that AC units either push very cold air or not at all, when they work at the 100% stage they're very noisy and uncomfortable, when compared to a much superior inverter-based heat pump that works all the time pushing air at the exactly perfect temperature (or even better, hydronic under-floor cooling).
> that works all the time pushing air at the exactly perfect temperature
When it spends a month or more over 37C with a dew point pushing 26C your inverter unit will also end up running at roughly 100% all the time.
> or even better, hydronic under-floor cooling
With a dew point of 80F your under-floor cooling just means you've got a river in your home.
Turns out the climate for most of Italy is pretty different from the climate of Texas. Who would have thought. Maybe that has some kind of impact to AC load.
Only if you have shitty insulation. In Italy I had very good insulation (a block built in around 2000, second floor) and I didn't need to even turn on the AC below 35.
> With a dew point of 80F your under-floor cooling just means you've got a river in your home.
Nah, shitty insulation.
> Turns out the climate for most of Italy is pretty different from the climate of Texas. Who would have thought. Maybe that has some kind of impact to AC load.
Nah, just shitty insulation.
> It's harder to justify the costs to practically rebuild a house when electricity is 12¢/kWh.
It's very easy because good insulation, hydronic cooling and inverter heat pump are much more comfortable.
What was the dew point? How many weeks was it 35c?
> Nah, shitty insulation.
Yeah just never open a door and it's never a problem.
It's really not the same climate in the slightest so it's not really a reasonable comparison.
Why do you need any cooling at all? I hear it's not even needed at the Arctic circle. So wasteful, must be your terrible technology and insulation.
> It's very easy because good insulation, hydronic cooling and inverter heat pump are much more comfortable.
I can assure you I'm quite comfortable without spending the nearly $50k gutting all the walls and ceilings to practically rebuild my home to save $50/mo during the peak times. It'll take quite a long time to just break even, and in the end it'll be only a tiny but different in comfort. I'll be sure to sob greatly in my spa after I watch a movie in the theater room tonight with my family thinking about the few percent efficiency loss in my AC if I had only spent another $10k to get the inverter unit. Magari potessi vivere in una scatola da scarpe.
Cheers.
Nope, your house will lose heat through the roof, through the windows and walls.
> Why do you need any cooling at all? I hear it's not even needed at the Arctic circle. So wasteful, must be your terrible technology and insulation.
Cope, dude. Cope harder. It's really funny how much you Americans cope about the primitive level of you housing; and I'm not even saying it's your fault: you've been fucked by the system, but you refuse to recognise it.
It's not heat it's humidity. You really just don't understand.
It doesn't matter if the heat eventually works it's way out or whatever. Open a door with the floor below 80f and you'll just get puddles form pretty much immediately.
You've clearly never lived in such a climate.
I understand very well. You're the clueless one who has never experienced a well insulated house.
> It doesn't matter if the heat eventually works it's way out or whatever. Open a door with the floor below ~80f and you'll just get puddles form pretty much immediately. It's called condensation.
Condensation is a symptom of bad insulation. With good insulation you don't have that.
> And once again, there's not much for your house to lose when the coldest it gets outside is over 80F outside for months at a time. Have you ever lived where the outside temp never dropped below 95F at night for a week? >You've clearly never lived in such a climate.
I have: try going to Sicily in summer and you might feel at home, but you're so obviously clueless it's funny. I'm arguing with a petulant child.
If that's your thought of a humid client, boy, you're in for a massive surprise
No it's not. The inland is dry (comparable to parts of Texas), while the coast can see 45 C (that's 115 F) and 90+% humidity in summer.
> It's not comparable.
It very much is.
> You've never experienced that humidity in Sicily.
You really make a fool of yourself. Very entertaining.
Have fun living in your expensive shoebox with $0.40/kWh electricity where you can't run a kettle and a stove at the same time. You can rest assured I'll be really sad and cry in my "oversized" home with cheap electricity.
Dude, good insulation, instead of your ticky-tacky shoe box, will make it easier for AC to work. You have serious reading skill issues (and you're talking about thermodynamics). Amusing.
Clothes dryers are usually 30A, and external AC units are in the 30A range as well for a medium unit.
You'd be having to do a lot of things all at once to even get close to 100A, never mind 200A.
Blowing your house breaker in the morning cause someone turned on a hair dryer while someone else was making coffee sound nuts.
A whole house breaker is 100, 150, now 200A minimum in new builds for single family homes. My 1br rental apartment from the 90s has 100A service.
Just because we only have one main circuit coming into the house doesn't mean you have to be careful not to run the vacuum and the stove at the same time...
In the past 30 days it cost me $48.74 for 591kWh of electricity to charge my wife’s EV.
For some scale: running a kettle, a washing machine at max temperature, a dishwasher, a microwave, a high-end gaming PC, and a conventional oven simultaneously, approaches a power draw of about 25 kW.
2.5 + 2.5 + 2.5 + 1 + maybe 3kW. How you got 25kW out of 11.5kW ?
The fix, apparently, is to upgrade to their 5 gbit service. A technician physically moves you to a different set of fiber runs. Then you call a month later and downgrade back to what you had.
I power my Fibre ONT with a PoE splitter, and the PoE switch is on a UPS. The AP's are PoE as well, so if power ever goes down, there's at least 45 minutes of continual uptime.
I think the ONT uses about 4W from memory, and the AP's about 6W a piece.
I had an FTTH provider with 100% of their network on natural gas standby generators. Went through a week long power outage without losing a single packet. You can support something like 100k households with well under 50kW of power. There are homes with larger generators than this. Docsis 4 would put you somewhere around half a megawatt.