the physical dimension you're looking for is power (kW)
443 kWh / 5 minutes = 443 kWh * (1/12 h) = 5316kW
There is already a similar tech for buses in Geneva, Switzerland:
https://www.hitachienergy.com/news-and-events/customer-stori...
There are two main ways of handling that randomness.
1. Spread it over a large number of vehicles, and let statistics average out the demand spikes. We're doing this at a significant rate, adding > 1 million EV's to American roads every year. Also, we already have superchargers with 98 stalls. There's going to be little demand difference between 98 350kW chargers vs 32 1MW chargers. 9 350kW vs 3 1MW chargers loads a grid harder, but 98 vs 32 not so much.
2. Batteries. Charging stations are already large enough that many are utilizing batteries to smooth electricity demands.
But if it did need to handle that level of instantaneous load, it would be straight forward to supply. 98 Tesla's worth of batteries on site could do it. The grid tie is substantially smaller, because the grid tie only has to handle average load, not instantaneous load.
Quick napkin math:
- The Hyundai Ioniq 6 gets 4.2mi/kWh (6.76km/kWh) [0]
- 3000km/6.76 = 443kWh
- 443 kWh in 5 mins = throughput of 2200 kWh, times however many charging stations at a refill stop. As EVs get more prevalent every charger at a station could be in use at the same time.
0 - https://insideevs.com/news/709706/electric-cars-energy-consu...