No, the earth pin is noticeably longer. This serves two purposes - first, to ground the device being plugged in before it is live; second, to retract the mechanical barriers that are ordinarily across the entrance to the power pins, in order that the plug can be inserted, but stray fingers, paperclips, keys, or other conductive items cannot (without some effort and intent).
As an aside - as a result of the mechanical barrier across the power pins, the plastic socket safety inserts that parenting stores sell are completely redundant, and arguably a scam.
The ground pin is longer because it is far safer to ground first before running current, and to continue to ground after disconnecting the current.
You have to insert prongs into both sides of the outlet at the same time in order for it to release.
http://en.wikipedia.org/wiki/NEMA_5-15#Tamper-resistant_rece...
The requirement only applies to dwellings (houses and apartments, not hotels or other commercial buildings), and only in jurisdictions which have adopted the 2008 NEC - the United States, unlike Canada does not have a national building code.
In addition, many jurisdictions have adopted the International Residential Code for One and Two Family Dwellings (aka, "IRC) which contains its own electrical requirements. While their is provision for tamper resistant receptacles in the 2009 IRC, many jurisdictions have remained on older versions of that code because the 2009 edition requires fire sprinklers in single family homes and therefore its adoption creates substantial political tension between building departments and the homebuilders whose fees fund those departments.
To put it another way, in the US, tamper resistant receptacles are not required in any non-residential structure, and because codes are adopted at the local or state level on an ad hoc basis, many dwellings are not required to conform with NEC 2008 or later versions.
Think of new editions of building codes like Windows, lots of people still use XP.
They are labeled with "TR". (There is also WR for water resistant, and of course TR and WR together, sigh. Prices are going up since now stores need to stock 4 times as many types.)
See: http://www.nfpa.org/itemDetail.asp?categoryID=1508&itemI...
It seems terribly inefficient to require fuses in every plug even when the electrical wiring may not need them.
Now that is inefficient!
This 1994 legislation made it the law that plugs must be fitted to certain consumer devices: http://www.legislation.gov.uk/uksi/1994/1768/contents/made
Before that time, almost everything (certainly everything I purchased) came without a plug and you had to buy a plug and wire it yourself. Probably because these things are expensive, and costs could be reduced by leaving them out.
I'm not certain on the exact motivation, but I think it's a mix of preventing people doing it wrong, and better mechanical properties (especially strain-relief) of moulded plugs.
It's also required now that the live/neutral pins be partially insulated (the 1/3rd closest to the plug or so) to prevent shock hazards to people curling their fingers around the plug when inserting or removing.
I remember us having to wire up kettles, lamps, and irons when I was a kid. And you'd sometimes go to antique (or second hand) shops and come across old appliances that had no cord attached. Anecdotally, we bought an old style telephone that we then had to wire back up.
That being said, I can't corroborate any claim that this was backed by legislation.
I have no idea how many sockets are installed in UK houses and how many plugs are fitted to UK equipment but a new plug / socket design would have to be God-Tier to justify the cost of replacement.
Also, I've seen people wiring plugs and it's sometimes scary, so anything that avoids the need for many people to botch a new plug onto their equipment is a good thing. And I guess this is where most improvement has happened - plugs that can be built quickly, cheaply and safely in Chinese factories for use in UK. You can change the fuse, but the plug is molded and you can't take it apart.
The IEC 60906-1 design linked by ricardobeat above, for example, can handle 250V at 16A and is way smaller and more compatible with other european standards. It was designed in the mid 80s, taking advantage of the new injection molding processes popularized in the late 70s.
I was wondering if there were any other designs that took advantage of the newer technologies since: I seem to recall a concept plug designed by an art student that was on HN a few years back that folded up rather neatly: does anyone know what happened to that?
It induces current in all metal near it, which causes sensitive devices to fail.
And it was only economical when you assumed a small number of high current devices. But these days when every outlet has something plugged into it the benefits are nill (since you have to have enough capacity for all the outlets, not just a small number of them).
Wikipedia has a nice explanation.
And you don't get hurt or break anything if you step on it :)
(Legally) imported products must conform to the local standards and pass inspection anyway :)
granted, the last time i looked at the paper was 2,5 years ago and there was still a lot of allowances for transition.
And i'm certain the Nokia adapters sold via local phone operators only have two plugs.
And don't even get me started on adapters for international products... Which btw, are the vast majority of brazil consumer gadgets.
When you imagine there are hundreds of millions of these plugs that bit of over-engineering really adds up. Really, when was the last time you plugged in anything above 2KW?
And yes, we have insulation on both "live" prongs.
Plus, it's the only kind of plug that's both Grounded, Polarised, Fused and has Insulated Pins[2]
[1] http://en.wikipedia.org/wiki/BS_1363
[2] http://en.wikipedia.org/wiki/AC_power_plugs_and_sockets#Comp...