Re:Why three prongs? by sc00ter on Saturday June 02, 2012 @06:50PM (#4059436)
" There's 3 prongs arranged in a triangle, each of equal length"

No, the earth pin is noticeably longer. This serves two purposes - first, to ground the device being plugged in before it is live; second, to retract the mechanical barriers that are ordinarily across the entrance to the power pins, in order that the plug can be inserted, but stray fingers, paperclips, keys, or other conductive items cannot (without some effort and intent).

As an aside - as a result of the mechanical barrier across the power pins, the plastic socket safety inserts that parenting stores sell are completely redundant, and arguably a scam.

Re:Why three prongs? by brudgers on Saturday June 02, 2012 @08:09PM (#4059618)
Most receptacles [in the US] do not have flaps or any other mechanical part. If they had the sort of contraption described, ungrounded plugs would not work and there would be a significant risk due to failure.

The ground pin is longer because it is far safer to ground first before running current, and to continue to ground after disconnecting the current.

Re:Why three prongs? by ars on Saturday June 02, 2012 @10:26PM (#4059848)
Not anymore. All new receptacles in the US have a protection that will not allow you to insert anything into just one side.

You have to insert prongs into both sides of the outlet at the same time in order for it to release.

http://en.wikipedia.org/wiki/NEMA_5-15#Tamper-resistant_rece...

Re:Why three prongs? by brudgers on Sunday June 03, 2012 @12:44AM (#4060074)
The change is in NFPA 70 - 2008, also known as "The National Electrical Code."

The requirement only applies to dwellings (houses and apartments, not hotels or other commercial buildings), and only in jurisdictions which have adopted the 2008 NEC - the United States, unlike Canada does not have a national building code.

In addition, many jurisdictions have adopted the International Residential Code for One and Two Family Dwellings (aka, "IRC) which contains its own electrical requirements. While their is provision for tamper resistant receptacles in the 2009 IRC, many jurisdictions have remained on older versions of that code because the 2009 edition requires fire sprinklers in single family homes and therefore its adoption creates substantial political tension between building departments and the homebuilders whose fees fund those departments.

To put it another way, in the US, tamper resistant receptacles are not required in any non-residential structure, and because codes are adopted at the local or state level on an ad hoc basis, many dwellings are not required to conform with NEC 2008 or later versions.

Think of new editions of building codes like Windows, lots of people still use XP.

Re:Why three prongs? by marshray on Saturday June 02, 2012 @11:23PM (#4059959)
I've never seen one of these things, not even at Home Depot.
Re:Why three prongs? by icarus_drowning on Sunday June 03, 2012 @01:04AM (#4060110)
I live in an older home (1955), but when we bought it in 2010 we had the original owner do electric work that had failed inspection-- as a result (and due to the local laws here), this is the only kind of socket we have.
Re:Why three prongs? by ars on Sunday June 03, 2012 @12:01AM (#4060025)
Look again - I had a hard time finding anything else last time I went.

They are labeled with "TR". (There is also WR for water resistant, and of course TR and WR together, sigh. Prices are going up since now stores need to stock 4 times as many types.)

Re:Why three prongs? by btgeekboy on Sunday June 03, 2012 @12:41AM (#4060070)
They exist, but they sell them alongside the normal ones at an additional cost.
Re:Why three prongs? by btbuilder on Sunday June 03, 2012 @11:06PM (#4062490)
Why would there be a significant risk of failure? Granted it would be more complex, but as the UK is a country of 65 million people I'd expect that if there were a lot failures the design would have changed by now.
Re:Why three prongs? by TazeTSchnitzel on Saturday June 02, 2012 @07:26PM (#4059517)
Oh, I notice the Earth pin is longer now that you mention it, you're right. Makes sense, considering it retracts the flaps.
Re:Why three prongs? by brudgers on Sunday June 03, 2012 @12:47AM (#4060082)
It's simultaneous pressure on the two live prongs which allows the plug to enter the receptacle - a two pronged plug still works.

See: http://www.nfpa.org/itemDetail.asp?categoryID=1508&itemI...

Re:Why three prongs? by quarterto on Sunday June 03, 2012 @09:20AM (#4060693)
We're talking about UK plugs here. It's impossible to insert a plug without the ground pin entering first. I've had a few double-insulated AC adaptor where the dummy plastic ground pin has broken off (in the socket!) rendering the plug unusable in most sockets.
Re:Why three prongs? by njs12345 on Sunday June 03, 2012 @06:32PM (#4061925)
If this happens and you don't want to replace the plug, you can get a pencil and put that in the ground hole to allow you to put the other two pins in.
Re:Why three prongs? by quarterto on Monday June 04, 2012 @06:17AM (#4063333)
I used another plug turned around along with some deftness.