> How many residential appliances benefit from three phase

I know of at least one, but I am ignorant of many other things and this just comes from my understanding of AC motors but: Any directly connected AC fan will have enormous benefits in terms of performance and efficiency with three phase.

Re:Why does the USA use 110V and UK use 230-240V? by Kirby64 on Tuesday August 29, 2023 @02:43PM (#37312081)
Low current devices such as AC ceiling fans use so little current that the wire gauge is largely based on the minimum sizing for code standards. At least in the US, you can't put anything smaller than 14 gauge (AWG) in walls. Maybe in Europe they allow much smaller gauge, in which case maybe it makes sense... but usually there are minimum requirements for wiring since it becomes a structural issue (i.e., too thin of wire will break easily when pulled).
Re:Why does the USA use 110V and UK use 230-240V? by quickthrowman on Tuesday August 29, 2023 @02:46PM (#37312119)
There is no benefit to performance or efficiency with a single-phase motor vs a three-phase motor.

Controlling the motor with a VFD is how you increase the efficiency and performance of a three-phase motor, simply being a three-phase motor provides no efficiency benefit other than you can use slightly smaller conductors to power the motor.

Re:Why does the USA use 110V and UK use 230-240V? by brianwawok on Tuesday August 29, 2023 @03:17PM (#37312510)
Why are large industrial motors three-phase? I almost always see large industry getting three-phase, which I assumed either gave more power or more efficiency.
Re:Why does the USA use 110V and UK use 230-240V? by thsksbd on Tuesday August 29, 2023 @03:58PM (#37313069)
It has nothing to do with efficiency (do the math on the conductor gauge and it all mostly cancels out) or power (idem) but the types of motors used (squirrel cage I believe).

The problem is getting the motor to start spinning. You cant start all motors on just one or two phases. And if a motor isn't spinning, it's essentially a short.

Re:Why does the USA use 110V and UK use 230-240V? by midoridensha on Wednesday August 30, 2023 @06:01AM (#37319645)
No, very large single-speed industrial motors are synchronous motors, not squirrel-cage (induction). These motors cannot start spinning on any number of phases: they can only run at the synchronous speed (which is dictated by the power line frequency and the number of poles in the motor). And it's not a short; it just doesn't run at all if you supply power to it; it only works once it's at the synchronous speed. These motors are used because they're the most efficient type of AC motor. Induction motors have "slip" of around 3% IIRC.
Re:Why does the USA use 110V and UK use 230-240V? by quickthrowman on Tuesday August 29, 2023 @05:20PM (#37314282)
Basically what the sibling comment said, it’s easier to start a three-phase motor, and a three-phase motor will also run more smoothly as it is powered by 3 sine waves 120 degrees out of phase with each other which provides constant power; versus a single-phase motor being powered by a single sine wave that outputs no power at the middle of the sine wave with two power peaks, which doesn’t run as smoothly as three-phase power with no points of zero power output.