Aside from kettles? I guess maybe some people have electric heaters? What else pulls enough power that the extra voltage will matter? Vacuums maybe, but no, those are limited to 1600W.
- Irons are commonly 2000-3200W (3200W is 14.5A at 220V)
- Portable Induction Stovetops are 3000W
- Deep Fryers are 2000-3000W
- Hair Dryers are 2000-2500W
And of course some things are connected via 3-phase 400V (3 220V phases, because of the 120° phase offset that's 400V between any two phases)
- actual oven + stovetop combinations, about 7000W for the stovetop, plus 1000W for the oven
- many tankless water heaters, 5000W-24000W seems common
The most impactful in day-to-day use are probably kettles and hair dryers, but with stovetops and water heaters there's probably a big difference in the prevalence in gas vs electrical, and tankless vs boiler simply due to wiring.
The 'industrial' level appliances are probably less of an issue, because the wiring run is limited and you can customize it however you need to. I could go down and buy a 36kW electric tankless water heater today and wire it up without any difficulty. Though it would probably be worth upgrading my 200A panel in that case.
Ranges sound like they're probably pretty similar. Typical modern electric ranges in the US are about 10kW.
Three phases would be handy for reducing the cost of wiring, though. Cost me $1500 USD just for the wire when I ran four new circuits last year. Couple of them were 50A, which is partly why it was so expensive, but mostly it's just that copper is $$$. Any bigger than 60A and I'd switch to aluminum.
For the a typical US house the standard feed into the house is 200 amps at 240v. So 48kW of power coming in we just segment it down a lot more.
> Lots of smaller (kw) circuits is safer than a few very large circuits.
Not fully convinced about the safety aspect but it definitely feels more convenient (can selectively turn rooms off if you need to work on something) - if I'm ever opening the walls, I'm going to switch to that approach. At the very least, I want to have a dedicated 20amp circuit in the home office...
Also I recently redid my kitchen and I added an additional 20 amp circuit just for the kitchen island outlets and it has been super nice.
Also with replacing all your breakers it can increase safety. But first the breakers are not cheap. Second it can lead to a lot of nuisance trips, albeit that is better than it used to be with modern breakers.
Breakers are probably going to be a bit cheaper and easier than opening all the walls to redo the circuits though...
The continental European system doesn't really solve it, as far as I know, so you have thicker wires on low power appliances than you would in the USA.
The fuse prevents that.
Ignoring the UK with their 13A/30A rings for a moment, since their wiring is unique.