Interior walls are simply heavy cut-ed 60x30x1.5mm vertical beams with horizontal ligatures made of flat iron 40x2mm covered with "insulation scotch" for noise reduction purpose. Wood planks are coupled vertically three/four maximum in the garage with a simple bar to hang furniture as a horizontal joint. Skirting and ceiling joint covers permit insertion and remove thank to the interior "female side" of the last wood planks cut-ed out before mount.
It was far more complex than what I consider at start (and I still have to finish many parts) but IMO it's cheap, good-looking and comfortable enough to being worth it. With that any kind of implant can be accessed directly without brake anything and when it's time to repaint it can be done again in the garden/garage instead of cover up anything inside...
These days with the prevalence of wifi that's not even necessary. Very often in a house a couple ceiling mount AP's, a drop to an entertainment center and into the study is about all I was motivated to do in my most recent house.
The cable/telcom providers though are the worse. The standard operation seems to be running a cable around the outside of a house and just punching right through the wall.
I think I put Cat6 STP or FTP in my home. Whichever it was, I wanted to have the best cable I could possibly find, because I don't want to have to redo this every 10 years.
Maybe another way to put it is this: doing a poor CAT6 install (as this article points out most are) isn't buying you anything over cat 5E, your spending money for nothing.
But yes, previously there wasn't much point to it. Cat 5e is good enough for 1GbE, and for 10GbE you need Cat 6A.
NBASE-T IMO is much more interesting for end users because by now USB adapters for those should be out and I fully expect them any week to drop. 5gbit/s runs up to 300 ft on Cat 5E. Also, while five gigabit is certainly doable for laptops with NVMe disks (last three years, since Skylake), ten gigabit is not necessarily so if you have PCIe 3.0 x2 (or equivalent) bottlenecks here and there. See, many Intel U chip laptops run the on chip bus between PCH and CPU at only a PCIe 3.0 x2 equivalent speed (aka 16 gbit/s) and the U chips provide PCIe lanes only off the PCH so if your data streams needs to cross into the CPU and if you are burning 10 out of the 16 for just Ethernet, not a lot will be left. And most of the time you need to cross the On Package Interconnect because the system memory hangs off the CPU side of it and all the peripherals the PCH side of it (northbridge vs southbridge, to use older terms). There's no such problem with 5gbit/s, you can even put twice of that on a 2GT/s OPI and still have bandwidth to spare.
Another potential such bandwidth choking point is the Thunderbolt controller, althought that might be past by now, because there is no JHL 7240 or Titan Ridge LP -- there was an Alpine Ridge LP which only used a PCI 3.0 x2 connection to the host meaning if you wanted to have a 5gbit/s USB A connection on your dock and you wanted 10 gbit/s Ethernet, you are already hitting all the constraints. Once again, 5gbit/s eases this problem.
In about five years when PCIe 4.0 and USB 3.2 are ubiquitous, well established features in laptops, that's when we can begin to discuss whether ten gigabit makes sense at home/small office.
Particularly as we are discussion cables, it should have just been a case of, oh we see your 250ft run doesn't' appear to be running without errors lets drop it down to 5gbit, or this link is running at 10% utilization lets save some power and drop it back to 2.5Gbit.
Also, 2.5G/5G Ethernet actually did not start out as an IEEE specification, but was started as NBASE-T/MGBASE-T.
From what I remember, the 2.5G/5G/10G devices actually will negotiate to determine the maximum datarate that will work.
What might have been more interesting is if they plugged those failing cables into a few switches to see if they actually were having problems anywhere. I'm betting they were probably mostly working fine. Although I have to wonder how many people are buying cat 6/6A for "future proofing" rather than actually running 10G on it.
The Cat5E run is nearly perfect, entirely away from power lines, and clean direct from one room to another.
So if your cable run is "port->long solid conductor cable->port" its going to give you some extra feet.
I haven't actually bought an ethernet cable for several years now, but cat6a always used to be quite a bit more expensive than cat5e. I just had a quick look, and here in the UK it seems it still is, at least for shielded cables:
- 30m UTP cat5e cable is £12
- 30m STP cat5e cable is £47
- 30m UTP cat6 cable is £14
- 30m STP cat6a cable is £100
All that said, the article does manage to skim over a few things it should have talked about. There are actual physical differences between the cabling specs which are a result of the 6A signalling requirements. The termination is _MUCH_ stricter and likely the cause of 99% of the failures in cases where the cables actually are 23AWG, properly twisted and isolated. Its these latter three things which will allow you to identify "real" cat6A rather than the stuff being relabeled by cable manufactures claiming to have found some secret method of making what are basically cat5E cables 6A.
(back to my 5e comment. The thing to keep in mind about a lot of this is that the standards specify minimums. The whole cat5E grouping was one where there was a race to out-specify everyone else, which is why you can find cat 5E 500Mhz labeled cabling, although most places just renamed it to cat 6 and charged a few cents more per foot. The other thing to keep in mind is that these specifications end up being given in loss/crosstalk per foot, so its quite possible to run higher data speeds on short cables that are non compliant per foot, particularly if they are terminated properly. Hence other comments I've made on this site about running 10GbaseT in my house on cat5E without any apparent signally/packet loss due to the runs all being very short.).