Re:Microsoft blames monster email outage on software defect ...
by cowlevel on Tuesday November 17, 2026 @04:13AM
(#50529178)
That's for a different type of motor. Synchronous motors always run at line frequency no matter the voltage; induction motors always run at a bit less than line frequency. And stepper motors run at the step rate, of course they're not directly connected to the grid because that wouldn't work, but they are also voltage-independent motors.
[ Parent
| on HN ]
Re:Microsoft blames monster email outage on software defect ...
by arghwhat on Tuesday November 17, 2026 @12:40PM
(#50535118)
nit: all motors follow their fields, and no motor is implicitly tied to mains grid frequency.
That we often bypass local field control and tie large industrial synchronous and asynchronous (induction) motors directly to grid is narrow and quirky special case that is common for historic raisins but really quite awful, with staged delta-star or dahlander winding relay tricks to go from insane start currents down to just absurd.
Brushed motors are just synchronous motors with a primitive mechanical field control attached, allowing them to reduce the field rate in response to load.