Re:US Construction worker productivity has dropped 40% in th... by matwood on Monday January 23, 2023 @12:32PM (#34492026)
PEX is great. I highly recommend keeping some shark bites and spare pieces of PEX around, as it's easy to do repairs on your own if you have an issue.
Re:US Construction worker productivity has dropped 40% in th... by joezydeco on Monday January 23, 2023 @12:49PM (#34492280)
I live in an area where the plumbing is soldered copper and the wiring is all in steel conduit. PEX, ProPress, Sharkbites, Romex... it's all just a little scary to me.
Re:US Construction worker productivity has dropped 40% in th... by latchkey on Monday January 23, 2023 @12:56PM (#34492397)
I seriously can't recommend this guy enough for general repair/building work...

https://www.youtube.com/channel/UCnorhjQR4zJkT7AVNhu395Q/vid...

Friendly, super knowledgable, takes the fear out of the DIY.

For electrical, I do a lot myself, but when it came to running a 50amp line + breaker panel inside my place (which also required outdoor ladder work) to replace the steel conduit indoors, I just hired a professional even though it was very expensive.

Re:US Construction worker productivity has dropped 40% in th... by joezydeco on Monday January 23, 2023 @01:07PM (#34492550)
It's not the DIY aspect^, it's the idea of ProPress joint sitting pressurized behind a wall for a decade.

^ I'm knowledgeable enough to do my own wiring and plumbing, but pay for licensed/bonded contractors instead. I sleep better at night and my insurance company probably does as well.

Re:US Construction worker productivity has dropped 40% in th... by latchkey on Monday January 23, 2023 @01:33PM (#34492959)
Up to you, but it honestly really isn't that much of an issue and I'd trust a simple properly crimped joint (which is easily visually inspected with a simple tool) a heck of a lot more than a welded one that is impossible to see what the inside looks like... um, did I put the right amount of flux on? did I know to use the 1/2 of solder to 1/2 of pipe trick?

As far as insurance companies... I bought an old place... I'm finding all sorts of stuff that isn't up to code (hidden electrical boxes, in the floor!, with wire nuts and not even twisted together wire and not even grounded properly)... I'm bringing it up to code, with modern products... in a court of law, it is going to be hard for them to argue against me.

Re:US Construction worker productivity has dropped 40% in th... by matwood on Monday January 23, 2023 @03:04PM (#34494201)
Depends on what you're doing. I've done quite a bit of DIY, and much of it is probably better than if I hired someone for the simple fact I care, and I'm not trying to do it as fast as possible.
Re:US Construction worker productivity has dropped 40% in th... by latchkey on Monday January 23, 2023 @01:00PM (#34492458)
From what I understand, while it is up to code, pro's don't put sharkbites in walls.

I've gone with ss crimps instead of copper rings too. Mostly cause I live near the ocean and the ss crimps just seem easier to use.

200' of blue/red sharkbite brand pex b tubing is only about $70 on amazon right now, amazing.

Re:US Construction worker productivity has dropped 40% in th... by conductr on Monday January 23, 2023 @01:32PM (#34492949)
If the walls are open, they shouldn’t. They should be using the minimum number of connections/joins because that’s always going to be a higher point of failure. However, When you/they need to patch something and don’t want to open up the whole room/house, then that’s the correct use case for these devices.
Re:US Construction worker productivity has dropped 40% in th... by matwood on Monday January 23, 2023 @01:56PM (#34493257)
I should have been more clear. I wouldn't use a sharkbite for a permanent fix, but being able to patch something until you can either do a permanent fix or get a plumber out is a big win. I even keep PVC glue and some collars/caps for the same reason.
Re:US Construction worker productivity has dropped 40% in th... by yamtaddle on Monday January 23, 2023 @02:42PM (#34493881)
Shark bite is awesome for capping a broken pipe until you can get around to a proper fix. Love those shark-bite caps. IMO every home owner should have pipe cutters for the pipes in their house (whatever materials those may be), and a set of those caps ready to apply for every size of pipe they've got. Ought to be as common as having a screwdriver and hammer. They're absolute life-savers when a leak or pipe burst happens at odd hours and you just want to get the leak stopped and the water back on and go back to bed or get back to work or whatever. Cut the pipe, steel wool the end clean, slap the shark bite cap on, get on with life until you have the time to properly fix it. Turns something very inconvenient into something merely a little inconvenient. Beats the hell out of having to break out the solder or pipe glue at 2AM.
Re:US Construction worker productivity has dropped 40% in th... by mindslight on Monday January 23, 2023 @03:43PM (#34494731)
If you've got a significant leak in a supply pipe, there should be a valve on the branch that will allow you to shut off just that branch rather than the whole house. You might need to shut off the whole house first while you figure out where that valve is, but you probably won't have to do ad-hoc plumbing to get most of the house back on.

But yes, in general I'm always for people becoming familiar with tools and DIY.

Re:US Construction worker productivity has dropped 40% in th... by latchkey on Monday January 23, 2023 @04:13PM (#34495134)
My place has no master valves in the bathroom branch for the cold water feed. I can shut off the hot water though since that comes from an on demand unit that I installed. I have to shut off the entire condo building (14 units) to do any work in there. You can be sure that I'm going to add a master valve to that branch...
Re:US Construction worker productivity has dropped 40% in th... by yamtaddle on Monday January 23, 2023 @03:58PM (#34494946)
Owned a half-dozen US houses built between 1907 and 2015 and have never actually seen such a thing. If you're lucky someone's done some work on a branch at some point and was courteous enough to install a shut-off, though usually off somewhere weird where there was already damage or whatever, not where you'd normally look for it.

[EDIT] Actually, my parents' very-new house has that... but because it's all-PEX, so it's super-easy to install it that way, with a central panel full of shut-offs for various parts.

Re:US Construction worker productivity has dropped 40% in th... by mindslight on Monday January 23, 2023 @04:33PM (#34495396)
Hah. I hadn't realized I was taking that for granted (over multiple houses myself), and just figured they were required by code (even though it makes the chrome sink shutoffs kind of redundant). Score 1 for DIYers doing more maintainable work than professionals.

FWIW a SharkBite valve or NPT adapter would seem to be a handier thing to have around than a pure cap. For one, you can attach a valve without shutting the water off.

Re:US Construction worker productivity has dropped 40% in th... by yamtaddle on Monday January 23, 2023 @05:36PM (#34496112)
Hell, maybe it is required by code in some places. I've only really looked at the plumbing of houses in a three-state cluster in the Midwest, maybe elsewhere more-conveniently-designed plumbing is normal.
Re:US Construction worker productivity has dropped 40% in th... by matwood on Monday January 23, 2023 @05:18PM (#34495914)
I had the main irrigation feed burst over Christmas and it's just a branch off the main line into the house with no valve! Had to turn the water off at the street, and couldn't fix it until the day after Christmas.
Re:US Construction worker productivity has dropped 40% in th... by jessaustin on Tuesday January 24, 2023 @03:37PM (#34509939)
How did that setup pass a code inspection?!
Re:US Construction worker productivity has dropped 40% in th... by mindslight on Tuesday January 24, 2023 @05:26PM (#34511459)
Maybe they're not in an area where it freezes, so the main shutoff doesn't need to be inside the house, and there's no need to shut off and drain the silcock in the winter?
Re:US Construction worker productivity has dropped 40% in th... by jessaustin on Tuesday January 24, 2023 @05:52PM (#34511773)
Let's assume all that is true. Still, shit breaks, and all branches off the main have to be valved separately. With the current setup, contamination (e.g. by sewage) of a branch couldn't be isolated from the house. That is not acceptable.
Re:US Construction worker productivity has dropped 40% in th... by mindslight on Tuesday January 24, 2023 @06:29PM (#34512150)
I was the one who started the thread thinking that shutoffs on branches were the norm, and apparently that's just not the case everywhere.

Also I don't know what you mean about sewage contamination? Sewage contamination of potable water lines would indicate a hugely weird problem.

AFAIK backflow preventers (fancy check valves), which prevent water in the house from going back into the municipal distribution, are standard on new installs. But I think that requirement is recent as of the past few decades, so most houses aren't going to have them.

Re:US Construction worker productivity has dropped 40% in th... by jessaustin on Tuesday January 24, 2023 @07:09PM (#34512493)
I suppose that depends on the typical age of houses in your area? Just as supply lines inside houses might get contaminated, supply lines outside houses might get contaminated. Perhaps from sewage, perhaps from runoff, or whatever. Outside lines are more likely to be broken by sloppy excavation, for example. Simple isolation valves are sensible even in situations that don't require backflow preventers, such as on a private well.
Re:US Construction worker productivity has dropped 40% in th... by mindslight on Tuesday January 24, 2023 @09:56PM (#34513817)
I still don't really understand what you're saying.

Yes, I agree isolation valves are good. But as far as what code requires? It seems that if isolation valves aren't required on branches, then the only isolation valve that is required is the main house valve that can isolate it from the street water main.

So I can't figure out what else you think would have been required to pass inspection in the comment you originally responded to.

Re:US Construction worker productivity has dropped 40% in th... by matwood on Monday January 23, 2023 @03:54PM (#34494901)
> there should be a valve on the branch that will allow you to shut off just that branch rather than the whole house

Haha...should is doing a lot of work here. Shut off valves like you mention are great, but even newer houses often don't have them.

Re:US Construction worker productivity has dropped 40% in th... by kevin_thibedeau on Monday January 23, 2023 @01:47PM (#34493139)
Sharkbites are a recipe for disaster when their O-rings fail.
Re:US Construction worker productivity has dropped 40% in th... by matwood on Monday January 23, 2023 @03:06PM (#34494226)
As I mentioned above, I should have been more clear about using it for emergency repairs and not necessarily permanent fixes. I also keep pvc pipe glue and some collars/caps around for the same reason.
Re:US Construction worker productivity has dropped 40% in th... by RetpolineDrama on Monday January 23, 2023 @04:05PM (#34495025)
>PEX is great.

PEX is very very not-great. It's constantly leeching carcinogens and endocrine disruptors into your sitting water. Your modern home's recirculation system is making that even worse, cycling hot water and concentrating leeched petrochemical products in your hot water line. Some of them even boil before water which means they'll make it through a distiller.

Plumbers like it because it's easy/saves them time, and they'll love charging you big $$$ to rip it out in 20 years when it's banned.