Re:A looming copper crunch and why recycling can’t fix it by xvedejas on Sunday July 31, 2022 @09:58PM (#32301017)
Split phase means we get the choice of 120V (for safety) and 240V when we really need it (eg appliances)
Re:A looming copper crunch and why recycling can’t fix it by jabl on Monday August 01, 2022 @12:39AM (#32302137)
Where I live it's fairly common for houses to have 230V single phase for most things, and then 400V three phase for things needing more power.
Re:A looming copper crunch and why recycling can’t fix it by ReptileMan on Monday August 01, 2022 @02:59AM (#32302920)
I am not sure that Western Europe is objectively worse at the safety department than us. Also you can always put a smaller breaker on 240.

The 120V in the US is a 640kb ram should be enough situation. You were first, thought you build the spare capacity, were surprised by the explosive growth and how useful electricity really is.

With modern homes moving to 100% electricity even 240 is not enough. In my flat I have pizza oven (3kw),inducation burner x 2 (3kw each), normal oven, 12000 btu AC x 2, tumble dryer, some other appliances that chug sub 1k... throw in some car charging, electrical water heater... A modern home is using orders of magnitude more electricity. And it is going up.

Re:A looming copper crunch and why recycling can’t fix it by manfre on Monday August 01, 2022 @06:12AM (#32303961)
You seem to be confusing voltage as the unit that dictates electrical load. Voltage x Amps is what dictates how many electrical devices you can use at the same time. Residential voltage is fixed at 120 or 240 with no chance of changing in our lifetimes.

As homes need more power, they are delivered more amps. The common for newer construction in the US is 240V at 200 amp or 400 amp for larger homes. Older homes will have anywhere from 80-150A depending on when they were built or remodeled enough to require replacing the main service panel.

Stove, HVAC, and dryer require their own dedicated 240V circuits.

Re:A looming copper crunch and why recycling can’t fix it by ReptileMan on Monday August 01, 2022 @08:04AM (#32304802)
I have not confused anything. The idea is that powerful applliences require more copper and bigger gauges for lower voltages (not linear). And we have more if them. So by upping the voltage we can save on the wiring.

In eu you don't have to think where to plug 2.5 kw space heater. Any outlet is good enough. In the US you have to. And with home appliances actually becoming bigger and more powerful I think that even the EU baseline will become too constraining eventually. Since usually there are limitation on the gauges that are ran from the main breaker to the sub-breakers (don't know english electric jargon)

Where I live I have a wire that can hold I think 40 amps in the wall from the main breaker to the board where the small breakers terminate the different home circuts. If I want to upgrade it is dig baby dig. 6 floors.

Re:A looming copper crunch and why recycling can’t fix it by sokoloff on Monday August 01, 2022 @05:56AM (#32303862)
Orders of magnitude more?

2 base 2 orders of magnitude perhaps, but not 100x more…

Re:A looming copper crunch and why recycling can’t fix it by petre on Monday August 01, 2022 @12:50AM (#32302194)
How do you resolve phase imbalances? Most generators are 3 phase. The system is othrewise well designed to use one or two phases when needed. We use one or three phass in Europe.
Re:A looming copper crunch and why recycling can’t fix it by eru on Monday August 01, 2022 @01:27AM (#32302381)
Different circuits in a single American household use different phases, I think.
Re:A looming copper crunch and why recycling can’t fix it by Scoundreller on Monday August 01, 2022 @01:43AM (#32302487)
Correct. Fun times trying to figure out why your power-line networking doesn't work.

The heavy load stuff is 240V anyway.

Re:A looming copper crunch and why recycling can’t fix it by petre on Monday August 01, 2022 @04:09AM (#32303322)
So it's the same way we do it in Europe with single phase, but I think it's easier to split three phases between single phase loads (most AC loads in a hosehold), rather than three phases between two phase loads (a few AC loads in a household). I still like the 120V plug connector with a key on the hot wire. In Europe I always wire the hot on the right hand side of the Schuko socket, as most standards have it on the right.
Re:A looming copper crunch and why recycling can’t fix it by eru on Monday August 01, 2022 @05:44AM (#32303807)
American outlets and plugs are barely usable. They go live even when you don't completely plug them in, yet.

The British plug is a pretty decent design from an electrical safety point of view. (However, they turn into caltrops in the dark.)

Re:A looming copper crunch and why recycling can’t fix it by petre on Monday August 01, 2022 @06:36AM (#32304126)
> The British plug is a pretty decent design from an electrical safety point of view

It's needlessly huge. I like type J (SN 441011, Swiss plug) and type N (IEC 60906-1, South Africa).

Re:A looming copper crunch and why recycling can’t fix it by eru on Monday August 01, 2022 @06:52AM (#32304235)
Yes, both of those would also work.

It's just that the American plugs are really the worst. See also https://www.youtube.com/watch?v=K_q-xnYRugQ for other badness.

Re:A looming copper crunch and why recycling can’t fix it by Scoundreller on Monday August 01, 2022 @01:48AM (#32302507)
Unless you're in a condo/apartment building where it's often 208V, not 240V. Kinda annoying when your "208V/240V" dryer puts out 25% less heat.
Re:A looming copper crunch and why recycling can’t fix it by jsjohnst on Monday August 01, 2022 @08:10AM (#32304858)
> Unless you're in a condo/apartment building where it's often 208V, not 240V.

208V (vs 220/230/240V) has minimal to do with it being a condo and everything to do with the type of incoming power. 208V is from taking two phases of a 120V three phase service. One phase to ground, 120V, phase to phase, 208V. For the alternative voltage (named 220/230/240V depending on context), the incoming power to the transfer is a single phase. The transformer then produces a split phase 220/230/240V where each phase is 180° opposite each other. The only reason you _might_ see it more frequently at a condo/apartment is due to there being a need or desire for 3 phase power.

Re:A looming copper crunch and why recycling can’t fix it by Scoundreller on Monday August 01, 2022 @02:27PM (#32310217)
At least around here, condos/apartments will have big elevator, water pump and HVAC motors and therefore prefer 3ph, so 208V is the "rule" rather than the exception.

Where it gets a little funny is that the Canadian standard for "industrial" power is 600V, not 480V, and that can make it hard to find replacements in some larger buildings with custom requirements.

Re:A looming copper crunch and why recycling can’t fix it by jsjohnst on Monday August 01, 2022 @10:31PM (#32314540)
> At least around here, condos/apartments will … so 208V is the "rule" rather than the exception

Yeah, didn’t mean to imply it was unusual, just explaining for others that it’s not a quirk of condos/apartments specifically.

> Where it gets a little funny is that the Canadian standard for "industrial" power is 600V, not 480V

Speaking of 480V, you ever dealt with 277V much? That’s a real “fun” voltage to be around when something goes wrong. :(

Re:A looming copper crunch and why recycling can’t fix it by Scoundreller on Tuesday August 02, 2022 @10:17AM (#32318755)
Probably the least common voltage in Canada. We’ll have some 347V though.

My condo parking spot has a wonderful looking junction box above it labelled “600V”.

But I’ve heard some Canadian factories will still get spec’d with “US Voltage” (ie: 277 and 480) for “standardization”, but probably so they can move the plant to the US without having to find electricians that can speak Canadian.

Re:A looming copper crunch and why recycling can’t fix it by jsjohnst on Tuesday August 02, 2022 @08:05PM (#32325974)
> Probably the least common voltage in Canada. We’ll have some 347V though.

Yeah, if you don’t have 480V, extremely unlikely you’ll have 277V. 347V has comparable issues to what I was referring to with 277. 480/600 aren’t voltage you’ll normally find wire nut’s in a jbox or behind say a light switch for example, but 277/347 you will. Unlike 120V though, if something were to cause it to arc (or worse, electrocute you), you’re going to have a very bad day! Not tagging off a circuit is always a bad idea, but especially when voltages are 250+.