The 120V in the US is a 640kb ram should be enough situation. You were first, thought you build the spare capacity, were surprised by the explosive growth and how useful electricity really is.
With modern homes moving to 100% electricity even 240 is not enough. In my flat I have pizza oven (3kw),inducation burner x 2 (3kw each), normal oven, 12000 btu AC x 2, tumble dryer, some other appliances that chug sub 1k... throw in some car charging, electrical water heater... A modern home is using orders of magnitude more electricity. And it is going up.
As homes need more power, they are delivered more amps. The common for newer construction in the US is 240V at 200 amp or 400 amp for larger homes. Older homes will have anywhere from 80-150A depending on when they were built or remodeled enough to require replacing the main service panel.
Stove, HVAC, and dryer require their own dedicated 240V circuits.
In eu you don't have to think where to plug 2.5 kw space heater. Any outlet is good enough. In the US you have to. And with home appliances actually becoming bigger and more powerful I think that even the EU baseline will become too constraining eventually. Since usually there are limitation on the gauges that are ran from the main breaker to the sub-breakers (don't know english electric jargon)
Where I live I have a wire that can hold I think 40 amps in the wall from the main breaker to the board where the small breakers terminate the different home circuts. If I want to upgrade it is dig baby dig. 6 floors.
2 base 2 orders of magnitude perhaps, but not 100x more…
The heavy load stuff is 240V anyway.
The British plug is a pretty decent design from an electrical safety point of view. (However, they turn into caltrops in the dark.)
It's needlessly huge. I like type J (SN 441011, Swiss plug) and type N (IEC 60906-1, South Africa).
It's just that the American plugs are really the worst. See also https://www.youtube.com/watch?v=K_q-xnYRugQ for other badness.
208V (vs 220/230/240V) has minimal to do with it being a condo and everything to do with the type of incoming power. 208V is from taking two phases of a 120V three phase service. One phase to ground, 120V, phase to phase, 208V. For the alternative voltage (named 220/230/240V depending on context), the incoming power to the transfer is a single phase. The transformer then produces a split phase 220/230/240V where each phase is 180° opposite each other. The only reason you _might_ see it more frequently at a condo/apartment is due to there being a need or desire for 3 phase power.
Where it gets a little funny is that the Canadian standard for "industrial" power is 600V, not 480V, and that can make it hard to find replacements in some larger buildings with custom requirements.
Yeah, didn’t mean to imply it was unusual, just explaining for others that it’s not a quirk of condos/apartments specifically.
> Where it gets a little funny is that the Canadian standard for "industrial" power is 600V, not 480V
Speaking of 480V, you ever dealt with 277V much? That’s a real “fun” voltage to be around when something goes wrong. :(
My condo parking spot has a wonderful looking junction box above it labelled “600V”.
But I’ve heard some Canadian factories will still get spec’d with “US Voltage” (ie: 277 and 480) for “standardization”, but probably so they can move the plant to the US without having to find electricians that can speak Canadian.
Yeah, if you don’t have 480V, extremely unlikely you’ll have 277V. 347V has comparable issues to what I was referring to with 277. 480/600 aren’t voltage you’ll normally find wire nut’s in a jbox or behind say a light switch for example, but 277/347 you will. Unlike 120V though, if something were to cause it to arc (or worse, electrocute you), you’re going to have a very bad day! Not tagging off a circuit is always a bad idea, but especially when voltages are 250+.