To that end, the live and neutral contacts in a British socket are shuttered. The long earth pin on the plug makes contact before the live or neutral pins are in the socket, and once in contact, raises a shutter to permit live and neutral to make contact. And the nether regions of those pins are insulated so that if a plug is halfway into a socket and something bridges the pins, it can't make contact.
This is a great design -- for space heaters and ovens and server racks. It's a bit less useful for the low power consumption devices that have come to dominate the market (where maximum draw is well under 1Kw -- often under 0.1Kw).
Mainland european grounded plugs pretty much all handle 15A/230V, and none looks like a battlecruiser (see the well-known and widely used "CEE 7/7" aka "Type E/F hybrid": http://en.wikipedia.org/wiki/File:CEE_7-7.jpg)
That's not really true, you can still get electrocuted if you put you finger on both bolts.
And that plug is massive. Luckily you can use any sticklike thing to allow continental plugs to be inserted (which incidentally I'm doing right now -- hello from Edinburgh)
And since the pins are angled, even a two-pin version is pretty hard to accidentally wiggle free compared to the two round pin European plug (I think some European countries have extra bits as well that might help?). Definitely does not deserve comparison to the awful American plug design.
Of course, that does break down a bit when you get to fuses, since you now have to worry about using different capacity fuses for appliances with different expected maximum power draw (3A for most things, 5A for the odd high-power small appliance, 13A for anything involving a heater...)
I've only ever lived in houses with the big uglies.
All lightbulb headaches have been due to IKEA and their foreign ways.
Given a choice between US plugs (spark, fall out of sockets, flimsy, dangerous, bendy pins), and UK plugs (Built to last, don't spark, fused, solid) I know which I'd choose.
There's also large advantages to having each plug individually fused - individual appliances blow rather than the whole circuit.
So I wouldn't say we're "stuck with huge plugs". The only real time it's a slight issue/pain is when you go on a plane and the cables take up a bit of space.
I prefer the UK plug too. But you missed one other very important point of pain: the pain of standing on one. As the flex on a UK plug leaves from the bottom, it has the unique property of tending to lay down on the floor with pins facing upwards.
That would be the point. Better to damage a plug slightly than get the plug through your feet.
http://en.wikipedia.org/wiki/AC_power_plugs_and_sockets#Type...
Edit: I'd just be happy if Europe picked a single standard and stuck with it. It's ridiculous to have to carry all sorts of converters for what are, in the grand scheme of things, not very long trips.
16A at 240V in a grounded plug that is very easy to protect against tiny fingers and that you'd have to be trying real hard to get your fingers on when inserting it, even in pitch dark.
Forwards compatible socket with the Euro plug. (that's the thin, ungrounded one with just two pins, one live, one neutral).
It will do anything from your phone charger to a light duty welder.
It's not really that it's forwards-compatible, but that the europlug was created specifically for this purpose. It's compatible with all european sockets but the english one I believe.
There is a mechanical/electrical machining process called spark erosion aka electrical discharge machining. Every time you have a spark a tiny bit of the metal of both contacts evaporates. Of course that's when you want it to happen, in sockets with plugged in loads you really don't want it to happen.
Over time this process accelerates and it has been the cause of many house fires in the US.
The fact that such sockets are placed in walls made of mostly wood placed right next to an upright stud does not help either.
Sometimes they're so bad you can actually smell the ozone.
And sparks are not the cause of many house fires, you just made that up. The sparks are harmless, and I've never seen a plug with erosion on it. Just because you can do it doesn't mean it actually happens.
American plugs spark (much) more frequently and strongly than their equivalent UK/EU plugs because the spring pressure from the side contacts is insufficient to maintain good contact over the lifetime of an installation, especially if the plugs are also worn. The fact that typically the current is twice as high doesn't help either (though if you get zapped it's less of a problem than in 230V installations, the US uses a balanced 110 system for most residential circuits where only a few receptacles which are of a different design have both sides of the step-down transformer outside of the house running to them).
The UK/EU plugs are of a much more solid construction than the American ones, as are the wallsockets they go in to.
I've seen US sockets that made an audible buzz while operating and get extremely hot (hot enough to melt the plastic). Not good.
The usual way in which it gets to this state is that a socket has been overloaded a couple of times, or heavy load is plugged in or removed while switched on, the contacts have corroded or have some soot build up on them and then the resistance increases enough to start a runaway process that ends with the socket failing altogether or with the socket getting so hot that the plastic outside cover will start to melt.
At that point all bets are off, especially in houses that are mostly constructed from wooden sticks instead of brick or concrete.
Another cause of trouble like this is that there was a short period when due to the supply issues with copper electrical wire made of aluminum was tried in residential installations in the US.
These required special fixtures so the wire would not come lose as the aluminum compressed over time thus shrinking away from the contact and causing an airgap and thus sparking.
This kind of wiring is no longer 'code' and if you have such wiring it wouldn't harm to periodically tighten up on the screws to ensure good contact.
Aluminum oxide build-up compounds this problem.
People always blame 'short circuits' for electrical fires, but most of the time this is nonsense, since the breaker will almost always instantly trip in a short circuit situation. That's what they're designed to do.
Half shorts (shorts that are of a resistance low enough to cause significant heat build-up and high enough not to cause the breaker to trip) and faulty contacts (intermittent contacts, sparks and thus heat) are a much more frequent cause of fire.
Another big cause of fire is counterfeit junk hitting the market and do-it-yourself types that don't know the difference using this to wire up that extra socket for a space-heater in the attic.
You have soot on your contacts???? Corrosion? Did it rain inside your house?
NEVER tighten aluminium contacts! You will cause exactly those problems that you describe. If there is a problem with it you need to remove it, apply the anti-oxidant paste and reinstall.
But aluminium to the contacts is very rare in america these days, where it does exists it's usually been pigtailed with copper.
In my two months in the USA, I observed more arcs and electrical crackling noises than I have in the rest of my life in AU.
Just my anecdotal 2c.
But I could be all wrong, as I'm no expert beyond having a drawer full of adapter plugs.
Rural areas, farmhouses, but one building I lived in in Toronto had a problem (a bad one) with one of the sockets and it was a fairly recent upgrade from what I remember.
> You have soot on your contacts???? Corrosion? Did it rain inside your house?
No, simply an installation from the 70's still operating in 2005. There are millions like that. And I don't live there anymore, I'm back Europe now.
> NEVER tighten aluminium contacts!
Not over-tighten, tighten. You should do it to the proper torque (there are special tools for that).
> But aluminium to the contacts is very rare in america these days, where it does exists it's usually been pigtailed with copper.
Yes, that's the slightly newer method, also since outlawed (and used as a way to fix problems).
The biggest problem I think with the alu wiring was not even that it could not work, but that people would use it with the wrong connectors, the al specific sockets were pretty pricey.
The only place where I know that aluminum is still used in residential wiring is on the entrance wire from the pole to the transformer, usually that's a very tricky connector that uses wedges to make the contact.
If I found myself in a house with aluminum wiring I'd probably rewire the whole thing just for safety. Costly (especially with the US system which staples cables to studs) but worth the peace of mind.
The correct installation uses anti-oxidant to seal it, then you tighten it enough to crack the aluminum oxide, and the anti-oxidant protects it. If you tighten it without fresh anti-oxidant you are creating a hazard.
And pig tails are not outlawed - quite the opposite, they are the recommended way to handle aluminium wiring.
Ah ok, I see what you mean now, yes that makes good sense.
As for the pigtails, as far as I know you can not make any new wiring with Aluminum in residential installations, pigtailed or not (I left my code book in Canada because it is of no use to me here, maybe there is some up-to-date online resource). Industrial use is still ok I believe.
Yes. But if you already have aluminium wiring you can - and should - add pigtails to it to make it safer.
"The only time its a slight issue"???
How about manufacturing, shipping, selling, storing, repairing, and paying for that overdesigned eyesore? How about looking at it? How about moving the couch out from the wall so the dang thing will fit back there?
* trip up a cable, and the plug falls out of the wall
(Pulling a UK plug out required force. It will not pull out)
Plus the cable exits a plug pointing downward, which
means it will not pull out via the cable.
* Sparks when you put a plug in or out.
* Bent pins that look like they're about to drop off
* No shielding on pins
* Often no mechanism to stop things being put in sockets
(All UK sockets only open once an earth pin has gone in
I wonder what the incidence of electrocution is in the UK vs US. I'm probably biased, but I certainly feel far safer here, especially having kids. > * trip up a cable, and the plug falls out of the wall
> (Pulling a UK plug out required force. It will not pull out)
> Plus the cable exits a plug pointing downward, which
> means it will not pull out via the cable.
This one is a mixed bag (trip up a cable, throw the expensive grandma lamp to the ground). > * Sparks when you put a plug in or out.
Not at all. Euro plugs earth pin always makes contact first. > * Bent pins that look like they're about to drop off
Bent pins? UK plugs are only marginally sturdier. > * No shielding on pins
What use is it? > * Often no mechanism to stop things being put in sockets
> (All UK sockets only open once an earth pin has gone in
All euro sockets have plastic spring-loaded linked stoppers that prevent accidental insertion of random stuff into the holes, and insertion of anything in only one hole (you need to push both sides together).Also, when you decide to put a lamp somewhere, you typically make sure the cable is not somewhere that can be tripped up.
But as I say, all rooms in the UK come with a fitted ceiling light, and a light switch by the door. So lamps are less common.
Ok, the alarm clock. or the hair dryer (into the bathtub! Yay!) or the wireless access point...
Hairdryers are usually used in bedrooms.
The last time I tripped over a cable was..... years ago. I can't even remember doing it. It's not an issue we have.
Yes, they do. (The UK, or even Europe, is not the whole world.)
> Hairdryers are usually used in bedrooms.
Hairdryers are used in bathrooms if there's a plug in the bathroom.
Sockets do not exist in bathrooms in the UK.
It is usually, but does not have to be, an overhead light.
An alternative that is also code-conforming is to have the switch control a socket (typically, the bottom plug in several duplex receptacles in the room) where a lamp is plugged in. Sometimes people don't actually plug a lamp in there, so the switch does nothing, and maybe that's what you've been irritated by.
If the wiring is done this way -- e.g., bedrooms and living rooms -- it can be quite flexible if you want to rearrange the room layout. You move the furniture and plug the lamp into the bottom receptacle where-ever it is convenient and sensible.
Cars kill 100 times more people than electrocution (not to mention severe injuries, which are rare for electrocutions), so they're probably a more important risk to worry about. Any slight difference in car accidents is going to swamp electrical concerns.
The latest source that I could find said that 400 people died of electrocution in 200, down from 670 in 1990.
I wasn't able to find any information on the UK. However, being from the US, I'd probably bet your wiring over there is safer.
Or did you mean that you only need to run one set of wire instead of multiple ones to multiple outlets?
I'm not sure why. Is the skin effect sufficient to explain this?
That uses way less cabling than any other network.
I wish someone would come up with a design which doesn't hurt so much when you accidentally tread on one.
http://www.minkyu.co.uk/Site/Product/Entries/2009/4/20_Foldi...
The promo shots of the final working model don't show how you get at the fuse, but I'd be very surprised if it has been overlooked. I suspect it's something to do with the red dots.
Indeed, the red dot is the plug cover. This set of blogspam pictures don't show it, but previous sets (the folding plug first made rounds in mid-2009) showed how the plug works. You can see an "action shot" simulation of the plug in the video: http://www.youtube.com/watch?v=f6DvjKkGT6s#t=1m46
They tend to rest on the plug's back, and hurt a lot when you step on them.
> Any other countries use them?
India and South Africa use the so-called Type D plug[0] (also called Type M in its 15A incarnation), which is similar but uses round plugs (type D is actually an older english standard). Some other south-east asian countries also use Type D. The english plug is called "Type G" and used in a number of former colonies and protectorates[1], especially in Africa and the Middle East.
[0] http://en.wikipedia.org/wiki/AC_power_plugs_and_sockets#Type...
[1] http://en.wikipedia.org/wiki/AC_power_plugs_and_sockets#Type...
The reason plugs in the UK are so big is that each one must be individually fused. And the reason for that is something called a "ring circuit".
In a ring circuit you have, say, a 40 amp fuse at the mains/box. From this you send out two wires, each rated only for 20 amps, going in a circle around the house. You can now supply 40 amps worth of power using only cheaper 20 amp wires. (Since the current can flow over both wires at once.)
But this means that the wires going to an individual appliance are far too small for the main breaker, so each appliance gets a fuse in the plug.
Ring circuits have serious drawbacks, but they helped during a time when there was a copper shortage.
And ever since then the UK has been stuck with huge plugs.