support/administration does not work well, i have a lot of really weird story's with them, from them plugging in a keyboard in our server to reboot it (without any reason) to taking down a server for a requested maintenance only to notice after 4 hours of downtime that they did not ask their bosses if they were allowed to even perform the maintenance requested (and then not getting permission to do so after another 2 hours ..)
For me it feels like there are some really deep issues somewhere in the whole administration that make incidents like this no real surprise
Problem is most other providers dont work any better, so ...
Everyone makes mistakes, let's just hope they learn from it.
The prices are high? Compared to what? Cheap is their raison d'être.
Just the bandwidth alone would cost us 3x what we pay at OVH if we were with one of the big cloud providers.
Sry if that caused confusion
Yup, been there multiple times in smaller hosting companies.
It's basically how it goes. They don't get serious about outages until revenue is severely affected and the brand damaged, they don't get serious about security until there's been a big breach or sales are lost because of lack of certification.
> in smaller hosting companies [like ovh]
> in smaller hosting companies [than ovh]
> Yup, been there multiple times, in smaller hosting companies.
I find it funny that anyone would think I would or could refer to them as small (and get away with it)
It is rather counter-intuitive. In neteng and dcops, "I don't know and I cannot find out. I can only attempt to mitigate what i think might have caused it for next time" is a very reasonable answer to 99% of the "why this happened?" questions because in order to replicate the situation to test the theory one needs to recreate the same problem again on the same scale.
This also means that certain things cannot be tested. Most of generator tests are garbage - turning on generator and running it without production load delivered over the transfer switch does not test anything other than that one can turn on a generator and run it. The problem typically happens not because the generator ( also is there the generator or the first and the second generator? Why is there no generator bank for a non monkey-sized company? ) does not start - the problem is because over time transfer switch develops a problem and unlike generators it is not possible to test a transfer switch where in the event of a test failure the customers won't lose power unless the data center is designed from the beginning to deliver A and B powers over separate circuits to every single customer and every single customer has per system ( not per rack ) transfer switches.
Of course it costs a lot more money, something that companies are reluctant to spend.
If someone doesn't know why a failure occured and they can't find out then they aren't looking hard enough
(In one case I experienced, the vendor reassured me that what I reported was not even technically possible -- until one of their engineers flew out and witnessed it firsthand.)
No expert on the field but that's the first time I can remember that a provider of that size loses connection to most of their data centres at once. That can happen with one product (eg S3 failure) but datacentre switches should work even if the rest is on fire.
It happened to GCE last year[1], though it only lasted 18 minutes.
[1]: https://status.cloud.google.com/incident/compute/16007?post-...
They just announced that they want to be a "hypercloud" provider on the scale of AWS and Google Cloud. I really hope that a power failure in Virginia couldn't bring down all of AWS.
So our lead Ops guy is unplugging half the redundant power supplies and plugging them into the new circuits, but a few critical servers are single PSU still, on UPS units. This is how he discovers that one of our PSUs has rotted and only has about five seconds of reserve power in it. Big outage, no bueno.
I'm much more interested in why the failure cascaded to other data centres – that's exactly what shouldn't happen.
I can not imagine they weren't tested.
But even the most rigorous testing can never reduce the total failure risk to 0. It seems OVH just got very very unlucky.
There was a DC in California a few years back that had three generators fail during a scheduled test and one of their server rooms had a blackout because of it.
Their generators are almost certainly tested frequently. But there could be any number of causes underlying the failure, and unfortunately sometimes failure does happen.
While generators are usually able to handle this with sufficiently low failure risk, the risk is increase due to the changing temperature
[1] https://www.accuweather.com/en/fr/strasbourg/131836/daily-we...
So, that one datacenter caused all other datacenters to die..?
It's explained here https://twitter.com/olesovhcom/status/928587258583748609 in French, they might post an English-language translation soon.
EDIT: The title on HN in misleading, summary from their CEO here – https://twitter.com/olesovhcom/status/928592231807713280
"guys we have a single point of failure in our architecture with SBG, maybe we should...
- naaah it's fine, we do not have time nor resources"
Then shit happens.
edit: I have no idea what is happening exactly, but OVH being what it is, it seems extremely weird that all datacenters "can" get down at the same time, and it looks like a serious architecture problem to me (or backup systems, like generators, not being correctly tested... whatever). I am really curious about the future explanation with what happened exactly
edit2: Why all the downvotes? Even the status page of OVH is down, do not tell me it is good design. We are not here to be charitable, but realist.