It's bog standard cheapest possible in Australia because it is standard in Australia - kettles their boil faster while drawing more amps.
If you follow that thought through ... 240 V will be cheaper in the USofA once wiring for EVs, home solar, smart grids, etc becomes more common.
> There’s nothing wrong with being ignorant. But choosing to stay there, that is an unforgivable choice
Something for all of us to reflect on.
US laundry rooms and kitchens have had standardized 240V outlets for decades. They’re just sized to deliver 40A+, and that means big breakers, thick wire, and big outlets and outlet boxes.
Installing a 240V outlet that can deliver 50A anywhere on planet earth is expensive because it takes expensive materials and labor to accomplish.
Copper costs what it costs in the US, Australia or Africa. Skilled labor that builds to code is expensive in those places, too.
This is not a standardization problem. It’s a physics problem, which dictates the cost of the system and cannot be affected by government regulation.
A standard Australian outlet is officially 230V at 10A. (It used to be officially 240V, but the standard was changed to 230V to harmonise with the EU standard; but given both figures come with error bars, this didn't necessarily make a difference to the actual voltage coming out of the wall.)
The US standardly uses split phase, in which a single phase of a three phase supply is split into two phases 180 degrees to each other, each of which is 120V to neutral, but 240V across each other; so the heavy duty US sockets use both of the split phases. (Originally it was 110V/220V, but was gradually increased up to 120V/240V over the 20th century.)
By contrast, in Australia, split phase generally isn't used except in rural SWER (Single Wire Earth Return) installs. Houses usually either get 230V single phase, or 400V three phase (sometimes still called 415V, which is what it was under the old 240V standard). A standard 230V socket is 10A, but there are also variations designed for 15A and 20A (plus more rarely 25A and 32A).
While most Australian houses only get single phase, a decent minority get three phase to supply larger air conditioners, or for EV charger and solar-battery installs. You also sometimes get houses wired with two out of three phases, which is different from the US / rural Australian split phase, in that you are getting two phases with a 120 degree angle between them, not two phases with a 180 degree phase angle.
However I am aware that most appliances that would use 30 - 40 amps are required to be wired in and not by way of an outlet. That's not to say that always the case, and since so much of the rural areas in my parts are single phase there's been times working around a rough country shed -- it'd be more than one outlet plus 15 plug that's melted because someone was pushing their luck with a hot welder.
I used to have an extensive book on the code two or three decades ago ... but code changes - possibly for when common sense ... doesn't. Below [1] might offer a guide as to how it's supposed to happen down under.
[1] https://cccengineering.com.au/design-memos/as-3000-explained...
A 240V 50A outlet requires a 6 AWG wire with four conductors. The wire is $10 per foot. The outlet is $50, the box is $30. The breaker for the panel is $100. Just material costs get you to $500. Throw in installation labor and you are easily north of $1,000.
If you think the two outlet types are even remotely similar in cost you really don’t have any business teaching this stuff.
And no, just because you have a 240V outlet in the laundry room doesn’t mean you can piggy back off of it for another outlet in the garage. You’d need a breaker rated for 100A and wire rated to deliver that kind of current, which I suspect would be even more costly than having two separate wire runs and circuits.
My frustration is that you have very little knowledge of how any of this works, but are recruiting equally ignorant children to engage in political activism to change building code in a way that will increase the cost to build new homes and cause more damage to the environment through wasted copper usage. All under the guise of educating them, ironically.
As they say, the road to hell is paved with good intentions.
Do you honestly think the reason some new homes a century ago were built without modern plumbing after it was invented was because people were unaware that such a concept existed? You think it was an information problem?
No, it was because of cost. Most people were fine using an outhouse or chamber pot and had done so all their lives. Sure, indoor plumbing would be awesome but the cost to install it wasn’t worth it to the buyers of new homes at the time. Which is exactly why people choose to omit a 240V outlet from a newly built home today.
Think of how many fewer homes would have been built back then if you mandated each one contain at least one toilet. You can’t just conjure things into being by enacting rules and regulations that say something must be so. In the real world things cost money and require resources to produce.
I strongly encourage you to watch some videos of electricians installing 240V outlets on YouTube and educate yourself on why they are expensive. Then go watch some economics 101 videos on the law of supply and demand, and what happens to supply when you artificially increase the price of a good through government mandate.
There’s nothing wrong with being ignorant. But choosing to stay there, that is an unforgivable choice. If you’re going to teach this stuff, get the knowledge you need to do it well and cut the political activism.
The kids will likely respond better and I think you’ll have more fun too. Understanding how electricity actually works in a house is way more fun than reading building code anyway.