There's probably a few lower cost things that I am overlooking, to the tune of netting out a few hundred dollars of savings after however many years they took to pay back.
In the UK, houses have energy ratings, which are largely not that useful, but they do allow estimated annual running charge.
The house that I live in we moved in and were spending ~1.7k on gas a year.
We needed to re-render the place, because it has a few missing pieces. we spent the extra £4 to put in 90mm of external wall insulation. We also had to replace the glazing. It was cheaper to get triple glazing (for some reason), however the results of that was that it was 6degrees warmer in winter, and 10 degrees (celcius) cooler in summer. Even with gas prices doubling, we spend about £70 on hotwater and heating.
How do you draw this conclusion? Like any other expensive, long-lasting part of the house, this should be seen as an asset which is “priced-in“ to the value of the building.
There are electric floor heating graphene foils that put out 20w per sqm, they're more than enough, no moving part, no maintenance, no bs, not even 20% of the price of a hydro floor heating, you can even install them yourself
Where I am your house would flood when 80mph+ winds blow the rain up your walls.
Same goes with the cinder block foundation. If insulated, it moves the freeze/thaw interface inside the block and then you end up with a failing foundation.
The end result is you're going to make big lifestyle changes to accommodate the energy. For example everyone sleeping in 1 bedroom and only cooking with an electric pressure cooker or low and slow with an induction range.
There are passive houses built at 2000m altitude in the Alps, some are made of wood and have literal strawbales for insulation, there are no excuses left in 2026 not to build good houses, it's more economical, more practical, more comfortable, more ecological
Any means to keep energy cheap and abundant must be by force because it is not a natural order.
Not everyone has the capital (even with gov subsidies) to make those investments, and it's generally the people who need to save a few bucks on bills the most that DONT have the money.
People still spend literal millions on poorly built and poorly insulated mcmansions today btw, it's not a money issue.
However, it's not that far off for retrofitting, if you do it when your siding already needs to be replaced. Add 3-5" XPS foam to the exterior of any standard house; if a basement you bring insulation several feet down and out below the ground. If cathedral ceiling, when replacing the roof you put 6-8" polyiso down over the sheathing before the new roofing material. If vented roof, get 1.5x code minimum blown in the attic. Air seal first, of course (1-hour of air sealing is the best ROI of anything you can do in an old house).
But nobody wants to put that money up.
https://planthardiness.ars.usda.gov/pages/map-downloads
https://commons.wikimedia.org/wiki/File:USDA_hardiness_zones...
A "properly insulated" house still requires something around 0,5 W/m2/K. Modeling a moderate 120 m2 house in the coldest months when the temperatures hit 15-20 negative you still need 2,5 kW of heat with domestic hot water on top. Put in the efficiency of a heat pump and you are still easily looking at half a mega watt-hour per month. ~1MWh for a whole house is very reasonable number during winter months, sans electric mobility.
That's entirely unrealistic to cover with batteries with current battery technologies alone, electricity generation is absolutely REQUIRED. Windmills can help soften the blow and storage needs substantially, but the TFA is about solar, which is effectively absent during the winter.
That was a good number in 1980 lmao (or in the US maybe), passive houses are often 1/5th of that. I'm talking 25cm+ of rockwool in the walls, 40cm on the roof and triple pane windows, mostly facing south, reasonably shaped house that conserve heat by design, etc.
0.5 W/m²/K is a good value.... for a window, certainly not for the overall house, for a wall it wouldn't even pass code in most of Europe
> That's entirely unrealistic to cover with batteries with current battery technologies alone
It already is a reality for many people.
There's a mix of miscommunication and wat. I'm using approximate floor area values here, not perimeter walls. 0.1 W/m2/K for a WALL is definitely not a "passive" house, that's barely A++.
> I'm talking 25cm+ of rockwool in the walls, 40cm on the roof and triple pane windows,
Yep, this gets you something like 0.5 realistic, maaaaybe up to 0.3 in the models.
> It already is a reality for many people.
Megawatt-hour level home-battery installs? Show us a picture. That's literally a room full of batteries. The actual reality is having ten or so kilowatt-hours to balance rooftop solar.
Spend 50k on insulation that will last the life of the building instead of 50k on heating and cooling devices which will need constant maintenance and replacement + fuel and end up costing 10x more over the life of the building.
A modern house with modern insulation in a mild climate shouldn't even need a central heating system. You can get by with 500w toaster heaters in each room for the coldest time of the year