If you actually had an electrician do it, I doubt they would've installed a breaker if they thought the wiring wasn't sufficient. Truth is that you can indeed get away with a 20A circuit on 14 AWG wire if the run is short enough, though 12 AWG is recommended. The reason for this is voltage drop; the thinner gauge wire has more resistance, which causes more heat and voltage drop across the wire over the length of it, which can cause a fire if it gets sufficiently hot. I'm not sure how much risk you would put yourself in if you were out-of-spec a bit, but I wouldn't chance it personally.
However! This strategy only works if the outlet was the only one on the circuit, and _that_ isn't particularly common.
(Another outlet type I've seen: I saw a NEMA 7 277V receptacle before. I think you get this from one phase of a 480V three-phase system, which I understand is ran to many businesses.)
Oddly, 14-50 has become the most common receptacle for non-hardwired EV charging, which is rather wasteful since EV charging doesn’t need the neutral at all. 6-50 would make more sense there.
1: when an uncle stops by for a visit with his RV he can plug in.
2: the other outlets in your garage are likely on a shared circuit. The 14-50 is dedicated, so with a 14-50 to 5-15 adapter you can more safely plug in a high wattage appliance, like a space heater.
2 is something I never thought of, I’ll have to keep that in mind.
If you own the house, sure. Many people don't.
I don't remember whether he ran another wire though. It was 5 years ago. Maybe I should not be spreading this anecdote without complete info.
He was a legit electrician that I've worked with for years, specifically because he doesn't cut corners. So I'm sure he did The Right Thing™.
Unless you performed the upgrade yourself or know for a fact that the wiring was upgraded to 12 gauge, it's very risky to just upgrade the breaker. That's how house fires start. It's worth it to check. If you know which breaker it is, you can see the gauge coming out. It's usually written on the wire.
> * Unless otherwise specifically permitted elsewhere in this Code, the overcurrent protection for conductor types marked with an asterisk shall not exceed 15 amperes for No. 14 copper, 20 amperes for No. 12 copper, and 30 amperes for No. 10 copper, after any correction factors for ambient temperature and number of conductors have been applied.
I could've sworn there were actually some cases where it was allowed, but apparently not, or if there is, I'm not finding it. Seems like for 14 AWG cable the breaker can only be up to 15 amperes.
New homes are probably worse than old homes through. The wires a just chucked in the space been the outer and inner walls, there's basically no chance of replacing them of pulling new ones. Old houses at least frequently have piping in which the wires run.