Re:PCIe 8.0 Announced by the PCI-Sig Will Double Throughput ...
by bryanlarsen on Wednesday August 13, 2025 @08:58PM
(#44895649)
If you drive an electric car in a rural area you might want to carry around 6-30 and 6-50 adapters because most farms have welders plugged into those and that can give you a quick charge. And also TT-30 and 14-50 adapters to plug in at campgrounds.
Re:PCIe 8.0 Announced by the PCI-Sig Will Double Throughput ...
by bri3d on Wednesday August 13, 2025 @10:21PM
(#44896097)
NEMA 6s are extremely common in barns and garages for welders. 6-50 is more common for bigger welders but I’ve also seen 6-20s on repurposed 12/2 Romex as the parent post was discussing used for cheap EV retrofits, compressors, and welders.
Re:PCIe 8.0 Announced by the PCI-Sig Will Double Throughput ...
by esseph on Wednesday August 13, 2025 @10:49PM
(#44896266)
5-20R/6-20R is also somewhat commonly used by larger consumer UPS for your computer, router, etc.
Re:PCIe 8.0 Announced by the PCI-Sig Will Double Throughput ...
by wat10000 on Thursday August 14, 2025 @04:52AM
(#44898271)
NEMA 6 is limiting because there’s no neutral, so everything in the device has to run on 240V. Your oven and dryer want 120V to run lights and electronics, so they use a 14 (or 10 for older installs) which lets them get 120V between a hot and the neutral.
Oddly, 14-50 has become the most common receptacle for non-hardwired EV charging, which is rather wasteful since EV charging doesn’t need the neutral at all. 6-50 would make more sense there.
Re:PCIe 8.0 Announced by the PCI-Sig Will Double Throughput ...
by bryanlarsen on Thursday August 14, 2025 @09:10AM
(#44899951)
Reasons why it's nice to have a 14-50 plug in your garage rather than a 6-50:
1: when an uncle stops by for a visit with his RV he can plug in.
2: the other outlets in your garage are likely on a shared circuit. The 14-50 is dedicated, so with a 14-50 to 5-15 adapter you can more safely plug in a high wattage appliance, like a space heater.
Re:PCIe 8.0 Announced by the PCI-Sig Will Double Throughput ...
by wat10000 on Thursday August 14, 2025 @11:18AM
(#44901435)
1 is why we ended up with 14-50 as the standard, too. Before there was much charging infrastructure, RV parks were a good place to get a semi-fast charge, and that meant a charger with a 14-50 plug.
2 is something I never thought of, I’ll have to keep that in mind.
(Another outlet type I've seen: I saw a NEMA 7 277V receptacle before. I think you get this from one phase of a 480V three-phase system, which I understand is ran to many businesses.)