https://sonoff.tech/product-review/product-insight/zbmini-ex...
I assume they hack what little power they need from the AC wobble? How do they do that without triggering a current leakage cutout though? Perhaps they “charge” when current flows for the first time?
The way it works is you put a bypass capacitor to neutral in the light fixture, and then it lets the switch be powered - no flicker or low energy requirements needed.
They're not open source so I thought maybe their other stuff isn't either. I didn't even know they made switches in fact.
Several of my friends have the homey, they're very popular here because athom is a Dutch company and they market here a lot. But I prefer the openness of home assistant.
Edit: Aah I see the confusion. The athom that makes the esphome devices is a Chinese copycat company that has nothing to do with the real athom but is trying to get a free ride on their name.
They've just received an injunction banning their sales in the EU and have to take back all their products sold here. https://community.homey.app/t/athom-wins-lawsuit-against-chi...
I had never heard of the Chinese company before.
Putting significant return current through ground means anything in the environment can be part of the path of least resistance. You will see small voltages across your house depending on what loads are on and there will be load-dependent noise conducted and radiated everywhere. This also puts the system one open circuit away from making nearly every conductive part of your house a shock hazard (if the wrong place in the ground network goes open circuit).
What is done in modern times is to have the current return on a neutral wire then monitor the ground wire for current and open the circuit when current is flowing back through ground (a fault).
Returning current through ground is impossible in Europe anyway due to residual current breakers. More than 30mA and the whole system shuts down.
And none of the light switches have ground either by the way.
Try putting a 50 mA fault and see if the GFCI does anything. It won't if you don't have a second line for return current.
This is different from ground. Neutral is the way the return is meant to go. Ground is a safety feature. Connected to the enclosure in some devices.
So sockets here have 3 wires: Live (Brown), Neutral (Blue) and Ground (Green with Yellow stripe). But the switches only have Live and the Switching wire (Black, the wire that goes to the light). The light then receives the switching wire and has Neutral. Because the power is consumed in the light and returns via neutral.
The switch doesn't need the neutral normally because it doesn't use any power. It just switches it on and off on the way to the light. But the wifi switchboxes do need it because they need to remain connected even when the switch is off.