Small note: the older single-room unit we have with the fan on the outside can ice up and make horrible noises then stall at a few degrees below zero (here in London UK)... B^>
Also: as the creator of a project called OpenTRV, I cannot but help admire your taste in naming! B^> B^>
FWIW the email address on your site page is bouncing for me.
Please do add my email (in my profile here) to a low-volume mailing/updates list if you have one.
And if my limited experience of bringing an open hardware project to market might be of help, let me know!
I would consider installing this in my open finished attic even though I already have a whole house ERV. The problem with a whole house ERV, particularly in a multi story house is that it doesn’t necessarily produce a lot of fresh air where you are in the house.
I’m excited for more competition in this space. Beyond the hardware I’ve found that HVAC installers are way behind the curve on air quality. I hope education and awareness increases in the industry.
Can someone expand of this?
intuition tells me that a regenerative design can be no better than 50% efficient, and would be worse at recovering latent heat
a counter flow heat exchanger can get the temperature higher than the average because 30c exhaust is meeting partially warmed intake, and 0c intake is meeting partially cooled exhaust.
Unless theres a phase change???
I was trying to reason it out, you have the thermal mass of the heat exchanger material, that you aren't going to be able to tune to every temp differential.
at the start of the cycle, it may be very efficient, but at the end of the cycle where the heat exchanger temperature is going to approximate the temperature of the air, efficiency is going to drop, and that would be happening along the length of the heat exchanger, so by the end of the cycle the inlet would be basically doing nothing, and the exhaust quickly getting to that point (in the best case).
I was starting to confuse myself at this point, so the constant temp model seemed easier to reason about.
Although, having written all this the model would basically be a constantly shortening counter flow heat exchanger? with a thermal mass not necessarily tuned to the temp diff.
So its still going to be worse than a counterflow heat exchanger, at least theoretically.
I'm not proposing this as a practical design, but it convinces me that 50% efficiency is not the limit.
This assumes that the heat exchanger has just enough thermal capacity so that raising/lowering its temperature by 5 degrees would get the air to the same temperature. In fact, it might be easier to imagine if the air doesn't blow continuously. Each chamber could fill up with air and wait for the heat exchanger and the air to get to the same temperature, before moving the air to the next chamber.
Anyway, I've tried to turn the very temporary influx of interest into something positive and lasting by searching for 2 people who can install and document the install of a pair of TW4 energy recovery ventilators, so anyone who wishes to buy thereafter can know what they are in for on that count. There is another guy Alex who will test flow and efficiency, I've already sent him the stuff.
So we get things tested and verified, and I will continue getting a jump on producing units by running the printers and assembling in between when I am doing the more respectably paid work in my life. The kits are on the back burner because even I am still stabilizing the assembly methodology. I even added a new component just recently, a flow straightener that boosts flow by about 10% while allowing noise to be reduced even further.
So stabilize, verify, produce, and then after that, within a couple months, I sell in a more or less ordinary way to anyone who wants them. I'm sorry it's not in time for the cold weather, but we have to remember ERV is about the big picture and long term. Like the rest of a building, it's an investment, and the machines are made for (very) good return and long lifespan.
I will prepare some WM12 units for those who have asked for them. To be clear I only got 12 emails expressing interest, not an absolute flood, but it's encouraging to know some people "get it" at least. I knew there would only ever be a small trickle of relatively wise people from around the world that appreciate good performance and return on investment. I only need to sell a few pairs per month to make it worthwhile, at the eventual $1300 CAD price tag.
I am open to scaling up production with more efficient production methodologies, but I am actually fairly well acquainted with injection molding, machining and other conventional approaches, and they aren't magic. They would help for sure but they wouldn't radically change the price, or the rate of return on investment, and they also take a lot of investment not just for tooling but also re-testing and re-design. I've also changed the design so, so many times after I thought it was done I am highly wary of being locked in.
I'm sorry I don't have a bunch of units ready to ship out, as the site says it's still in beta, I am to be honest kind of taking my time because I have another project, the big quiet fan, which is actually funded a little better, and thus I've been directing most of my time to that. But I do advance this a bit most days. I have a twitter where I tweet my progress : @open_erv, and also I'm on bluesky.
I have shipped a few units to other engineers who have/will test the units so I can share third party confirmation for any skeptics.
To clarify some of the discussion, it is not a counterflow heat exhanger, it is a regenerative type. https://en.wikipedia.org/wiki/Regenerative_heat_exchanger. I prefer this type because they can recover latent heat more effectively than recouperative (such as counterflow) type, and latent heat is 40-50% of the total energy content of the air, seasonal average in Ottawa or Toronto.
I am hoping to get the machine tested by the PassiveHaus institute to show beyond doubt how good the efficiency is with a third party test. I have no doubt, I have tested it myself, though.
These can theoretically handy any temperature differential, but the TW4 and WM12 are currently made of a polymer that I wouldn't trust in an extremely hot climate combined with direct sunlight. For that reason, I am focussed on cold climate scenarios. I am pretty sure it will not frost up even in extremely cold weather like -30. I used it last year in my window and had no problem, and it did get to like -25 at least iirc.