Which is quite a lot of the country.
Light blue is a typical Winter low point in the -10°F to 0°F, which means you will see -15°F or lower often enough to worry about it.
https://www.energystar.gov/ia/partners/bldrs_lenders_raters/...
Though heat pumps are unique in that they produce less heat as the colder it gets - A few hours of -15º every few years shouldn't be the primary consideration in spec'ing a system that still produces 75% of its heat in that worse case.
I live in that blue area and ran through all of the math and considerations recently - I pulled the hourly temperature data for 6 years. Of the 94,000 data points in that period, a total of 26 hours were below -5º: https://imgur.com/a/P7A3kan
> Our modeling finds that even if Focus incentivizes 800,000 heat pumps with electric resistance backup (10 times the number of heat pumps as it did furnaces in the past four years), the state will still be able to meet its electricity demand with currently operating power plants, even on the coldest days. Depending on the efficiency of the heat pump, in-state winter generation capacity would still exceed peak demand by 1,400–4,300 MW on the coldest day.
https://rmi.org/three-questions-wisconsinites-are-asking-abo...
One of the states in the article is Oregon too, where I have family that just a few weeks ago lost electricity for 4 days, but were able to use an electric generator to keep the air handler going and gas to heat the the house and cook.
I fear heat pump only heat will fail exactly when I most need it not to.
She had to get a hotel room for the night because she wasn’t comfortable sleeping with the gas fireplace on.
⸻
1. I would guess that thermostats also powered by electricity not working would add to the complication.
Natural gas is just a very convenient and very dense source of energy when you need it most.
We have an (almost[1]) all electric house. A year ago we lost power for six days. Last spring we had a generator installed. Over the summer we lost grid power for five days but the generator worked flawlessly the entire time.
I don't like having gas for a number of reasons and if the grid was more reliable we would never have bothered, but, for us, it's just so much more reliable.
[1]: We have two HVAC systems that service different sides of our duplex-ish house. One side is a ground source heat pump, the other is a 95% efficient gas furnace.
Oddly enough, it tends to snow when it's cold. Even rain can a problem since the nature of a heap pump means the unit is cooler than the surroundings.
So often for a few nights of the year, the alleged "heat pump" actually just falls back to electric heating.
For now - and only in part of the country. Most of the newest models can output 100% of their rating down to something like -5ºF -- they're easy enough to oversize as well, so if your 99% heating load is e.g. 48,000BTU, a 60,000BTU heat pump that's only outputting 80% of rated BTUs due to the extreme cold can still cover the full design load.
Here's the spec sheet for the newer Mitsubishi hyper heat models - 87º output at -4ºF and 76% output at -13ºF -- very few places in the states ever get that cold: https://static.appliancesconnection.com/attachments/D5bf5709...