The delta-T that is correctly cited as being "around a max of 20°F" is the delta in temperature across the evaporator (IOW between the return duct and the supply duct). It's not the delta-T between the outside air and inside air.
With good enough insulation and/or enough cooling, you can get whatever delta-T you want as is obviously the case with refrigerators and freezers.
well said. i have temp sensor on supply and return and I graph them and delta, to make sure that hvac works within proper parameters. otherwise during heat waves you start thinking that hvac maybe out of shape
One more question- what about commercial spaces where they will have a door open and be flooding the store with ice cold air. It sure feels like more than a 20 degree difference.
That has (essentially) nothing to with the relationship between the indoor and outdoor temp.
For simplicity, imagine a balmy 110°F outside temp, an 80°F inside temp. That's 30°F from inside to outside [and will feel refreshing], but probably results from a supply temp [the coldest air coming right out of the vent] at 68°F, a return temp [the air being drawn into the AC duct] of 88°F.
The key 20°F delta-T is the measure between the 88°F and the 68°F (both temperatures inside the conditioned [in other words, "indoor"] space). All of the other temperatures can be all over the place. Even if the outside temp was 120°F, provided the unit was sized large enough or the insulation good enough, the indoor air might average 80°F and keep the same 88°F/68°F [20°F delta-T].
As a more extreme example, your freezer probably works on a delta-T of ~10°F. That's the difference between the air going into the evap coil area and the outlet. If your indoor kitchen temperature is 80°F, your freezer still keeps things frozen even though its delta-T is only 10°F. You don't take the 10°F from the 80°F. You take the 10° from the 30-ish°F and get a warm temp of 30°F and a cold temp of 20°F in the freezer.
are you sure ? at summer I have walls that are 170F outside (at 2pm) and 80-90F inside. Also, window will pass through heat only during the day. Wall will keep heating your inside air through the night as well. Get some cheap thermal camera - it's very educational.
You should also check your ductwork/registers. To see if there are any tears/openings/etc. Also, in case you are using flex duct, if it's not tensioned properly, sagging, etc - there will be a lot of air velocity losses that reduce overall cooling experience.
>Any idea why the HVAC guy and just about every source online insists that A/C can only give you a temperature delta of 20F? I know it can’t be true, but that claim is everywhere.
Something around refrigerant properties, mechanics and physics, etc. I also spent some time in this rabbit hole
During summer, the night temperature drops to the low 90’s here. It’s A/C all day, every day, for at least 3 months.
Any idea why the HVAC guy and just about every source online insists that A/C can only give you a temperature delta of 20F? I know it can’t be true, but that claim is everywhere.