Re:We need a lot more electricians if we’re going to electri... by kuschku on Wednesday January 11, 2023 @11:31AM (#34340315)
The service drop in EU/UK is 380V. The point stands.
Re:We need a lot more electricians if we’re going to electri... by sbradford26 on Wednesday January 11, 2023 @11:40AM (#34340485)
So that 380V would be for 3 phase to a home which is not always the case. There are plenty of homes in Europe that only have single phase to the house which is at 230V.
Re:We need a lot more electricians if we’re going to electri... by throwawayacc3 on Wednesday January 11, 2023 @11:47AM (#34340597)
That is incorrect. The EU/UK are on 230V at 50Hz at residential service entry. The point does not stand.
Re:We need a lot more electricians if we’re going to electri... by Symbiote on Wednesday January 11, 2023 @02:04PM (#34342926)
This varies.

Houses and apartments in Denmark have 3 phase service. My apartment's main breaker is labelled 40A @ 380V.

I believe the oven and hob make use of it, but I haven't looked myself.

Re:We need a lot more electricians if we’re going to electri... by petre on Wednesday January 11, 2023 @12:24PM (#34341194)
400V between phases, 230V phase to neutral. Most homes have single phase though.
Re:We need a lot more electricians if we’re going to electri... by kuschku on Wednesday January 11, 2023 @12:46PM (#34341603)
So how would you run an instant water heater or electric induction stove then? Every apartment and house I've ever lived in had 380V three-phase right to the kitchen, to the bathroom, and to basement rooms (e.g. for prosumer workshop tools).
Re:We need a lot more electricians if we’re going to electri... by danans on Wednesday January 11, 2023 @01:29PM (#34342362)
> So how would you run an instant water heater or electric induction stove then? Every apartment and house I've ever lived in had 380V three-phase right to the kitchen,

I run an induction stove on 220V single phase every day here in the US.

Re:We need a lot more electricians if we’re going to electri... by petre on Wednesday January 11, 2023 @01:38PM (#34342508)
Isn't it two phase? AFAIK in the US you have 240V two phase with 180° between them.
Re:We need a lot more electricians if we’re going to electri... by danans on Wednesday January 11, 2023 @02:00PM (#34342858)
Re:We need a lot more electricians if we’re going to electri... by petre on Wednesday January 11, 2023 @01:36PM (#34342483)
I wired one phase to all the burners and the oven. They're on a separate circuit with a 16 amp fuse. It's 2200W. Has mever tripped. 400V is just not very common for residential in the EU, maybe in the UK you have electric boilers and other powerful appliances. I had a good laugh when I saw that your codes require an electrical connection between the two taps. Makes total sense from a safety perspective but it's still funny.