Fresh air / circulated air -> Perfect 16[1] -> HVAC
I highly recommend it. You can also get an ERV or HRV to utilize heat/humidity when bringing in outside air.
My main gripe with the Perfect 16 is that it doesn’t do any of the multi gas stuff ( https://www.iqair.com/room-air-purifiers/gc-multigas ), and is more like running a HealthPro ( https://www.iqair.com/air-purifiers/healthpro-series ).
https://leesheatingandcoolingservice.com/wp-content/uploads/...
The 216 filter has 0.17" wc of initial pressure drop at 1000 cfm as compared to 0.12" wc for its MERV 13 equivalent, the 213. You can just swap it in if you started out with MERV 13 [0] have 0.05" wc of extra pressure budget (and an existing compatible housing), and you can probably save 0.05" wc by just changing your filter more often. Or you can design something like this into a new system, just like you would have to design a Perfect 16 in.
[0] You must have some kind of return air filter to avoid destroying your fan coil. MERV 13 is somewhat of a baseline for a decent system.
https://www.iqair.com/us/whole-house-air-purifiers/buy
That’s… a lot more expensive than Aprilaire for only slightly better performance. Two or three Aprilaire (or Lennox, etc) filters in parallel will dramatically outperform the Perfect 16 and will cost much less. Of course, that would require some custom sheet metal, but the Perfect 16 may also need some custom sheet metal.
I'm not yet convinced that they are worth 3k more than a pico and a fan, at least as a retrofit.
(That’s uglier, but surprisingly difficult to find).
https://en.wikipedia.org/wiki/Heat_recovery_ventilation?wpro...
An HRV or ERV is designed to pull in fresh air without losing heat from inside (or while keeping the heat outside in the summer), by transferring heat between the air being drawn in and that being exhausted.
In my house. 9 X main lights. Kitchen work lights. Extractor fan. Oven Hob (gas) Dishwasher Washing machine Dryer. Fridge. Freezer. Food processor Kettle Toaster. TV. Digi box PlayStation (2 but anyway) Extractor fan Boiler Laptop Printer 5 X lamps.
So I managed to get to 30 things. I'm not entirely sure I'd want to hook up all those things to a network though...
Also, latency is very relevant for IoT stuff. Lights turning off 2 seconds after you push a button is a crappy experience.
A better solution is to open one window on each floor in addition to turning on the exhaust.
There are several kinds of HVAC systems for fresh air ventilation and free cooling (HRV/ERV) and it was a huge bummer to hear an ac expert say "your tiny house's tiny closet has no space for any new toys at all"
GP was wanting to take advantage of the more favorable outside air (lower sensible and latent heat) and just do filtered air exchange directly with the outside rather than running the compressor.
Introducing cold, saturated air to your warm house will not, in general, make it feel nasty and humid.
While I don’t want the walls sweating, I could imagine there are industrial or commercial environments where moisture level matters a lot. Electronics plant: dry is always bad! Want some moisture to dissipate static. A library wants low, but not zero moisture. A manufacturing plant wants it to be very consistent. A fruit market wants its humidity high.
In a residential environment, it’s a toss up: some stuff wants to be dryer while other stuff doesn’t.
That link seems to be discussing a situation where there is too much humidity coming in relative to the amount of heat the A/C needs to remove, and that hits my pet peeve about air conditioning design. Air conditioners generally run at a roughly constant coil temperature, which means that there is no independent control over dehumidification versus cooling. If you happen to be at the design conditions, great. Otherwise you don’t end up with the humidity you want.
I know of one system (“dynamic humidity control” by Chiltrix) that adjusts the coil temperature to control humidity. As far as I know, any hydronic system can do this with minimal modification, but I don’t think it’s popular.
My "smart" thermostat has a settings for this, but I seem to be at its algorithm's mercy instead of specifying: "50% RH or less, no change, 50-70%, -2C to the set points, 70%+, -3C to the set points".
Let alone being able to do dehumidification only.
Heat recovery ventilation (HRV), which uses a sensible heat exchanger, is sufficient in temperate climates but otherwise you need to be able to transfer latent heat also to reduce humidity, so need the ERV.
It is like pouring 200ml of water from a 1000ml jug into a 200ml jug. Same water, higher % fillage (to use a technical term).
It’s just not been worth the cost, usually.
It's not usually a feature of residential units, but commercial ones also have a bypass for when the building management system detects (using sensors like wet-bulb thermometers) that the outside conditions are fine to bring inside, which is called the "economy cycle". It switches off the baffles to the HRV or ERV and just brings the outside air in directly.
If somebody was really interested, that could be implemented at home with some extra ducting, some controllable dampers, sensors, a Raspberry Pi, etc.
I am wary of a product sold by only one vendor. Economizers tend to be added to large central ducted commercial HVAC systems and this is the only window unit I’m aware of.
EcoBreeze 2.2 - Nature's Cooling Solutions® https://naturescoolingsolutions.com/ecobreeeze-2/
Hell a modern AC can probably do with only filtered venting, with a heat exchanger which gets disabled when using external air to get to the target temperature.
In fairness, said openers wouldn't be able to talk to our proprietary thermostat.
The heat pump we bought is great, though.
I don’t like having to shut off my furnace and manually manage windows. But I also don’t want automatic windows. I just want it to be like, “you’re asking for 21C and we can get there by pumping in outside air rather than using an AC to transfer heat from the inside air to the outside air.”