Re:I Ripped Out a £6k Lighting System by quickthrowman on Sunday November 15, 2020 @11:54AM (#25102569)
> I did all that work myself because the electrician didn't understand words like "crosstalk" and I didn't want to find out after I moved in that the wires in finished walls didn't work.

You hired a bad electrician. Any good electrician knows you can’t run power and data in the same conduit or pathway. NEC requires a divider in any junction box that contains low-voltage and line-voltage power, and also requires separate conduits/pathways for low-voltage and line-voltage power (can’t use the same stud hole to feed both through)

Spend more money on the electrician, and they’ll be better at their jobs.

Edit: I run electrical work

Re:I Ripped Out a £6k Lighting System by grecy on Sunday November 15, 2020 @02:22PM (#25103905)
More than that, there are laws (at least in Australia) about how data cables must be run.

Similar to how close an electrical outlet can be to a sink, there are rules about how close a data cable can be to a current-carrying cable.

Re:I Ripped Out a £6k Lighting System by youngtaff on Sunday November 15, 2020 @04:41PM (#25105158)
In the UK CBus have CAT5 cable that's rates for installation alongside mains cables (back of lightswitches etc) https://www.cbusdirect.co.uk/cbus-product-range/cbus-cable-a...
Re:I Ripped Out a £6k Lighting System by WalterBright on Sunday November 15, 2020 @06:49PM (#25106158)
The low voltage in the house is completely separated. The wall outlets are widely spaced. It even comes into the house in a different location and a different trench.
Re:I Ripped Out a £6k Lighting System by shawnz on Sunday November 15, 2020 @11:56AM (#25102590)
> Any good electrician knows you can’t run power and data in the same conduit or pathway. NEC requires a divider in any junction box that contains low-voltage and line-voltage power, and also requires separate conduits/pathways for low-voltage and line-voltage power (can’t use the same stud hole to feed both through)

Sure, but aren't those rules for safety purposes and have nothing to do with crosstalk/interference?

Re:I Ripped Out a £6k Lighting System by quickthrowman on Sunday November 15, 2020 @12:20PM (#25102806)
Yes. My point is that an electrician who ignores (or isn’t aware of) NEC rules isn’t anyone I’d let near my home’s electrical wiring. Almost all NEC rules are for safety.