What about common mode induction - when the inducted current flows in the same direction in all strands of wire (regardless of twisting) with earth return path? This is what AFAIK causes the problems with power transformers and can happen on long metal pipes too.
[ Parent
| on HN ]
Re:Solar Storm of 1859
by londons_explore on Monday May 04, 2020 @09:08AM
(#23067555)
Common mode induction is an issue in any twisted pair system.
As long as the DC impedance to ground anywhere is <500 ohms, I wouldn't imagine enough voltage to build up to break down even a tiny signal transformer. In power systems, the connection between neutral and earth does that.
Long ethernet cables might be a concern, since the common mode DC impedance at the termination is normally infinite... Analogue audio equipment also frequently has infinite common mode impedance to prevent ground loops.