Common mode induction is an issue in any twisted pair system.
As long as the DC impedance to ground anywhere is <500 ohms, I wouldn't imagine enough voltage to build up to break down even a tiny signal transformer. In power systems, the connection between neutral and earth does that.
Long ethernet cables might be a concern, since the common mode DC impedance at the termination is normally infinite... Analogue audio equipment also frequently has infinite common mode impedance to prevent ground loops.
Re:Solar Storm of 1859
by spdustin on Monday May 04, 2020 @09:15AM
(#23067639)
I really hope you take to heart the sources and links that people will respond with, and not just switch to defensive mode. This is a dangerous topic, and important to get right.
As long as the DC impedance to ground anywhere is <500 ohms, I wouldn't imagine enough voltage to build up to break down even a tiny signal transformer. In power systems, the connection between neutral and earth does that.
Long ethernet cables might be a concern, since the common mode DC impedance at the termination is normally infinite... Analogue audio equipment also frequently has infinite common mode impedance to prevent ground loops.