After reading your comment it did make me wonder as I plugged our coffee machine this morning how the design substantial chunk of plastic and metal I was holding was influenced by the aftermath of WW2.
Now of course it was "overengineered" by the standards of the time, to compensate for our ludicrous, dangerous, and still-legally-required "ring main" system, which as you say was due to aftermath-of-WW2 copper shortages. But the plug design is the part we got right.
Evidence: Socket: http://i.imgur.com/zwRYC25.jpg Mask: http://i.imgur.com/b0RAZ9k.jpg
What makes you think ring circuits are dangerous? Incompetent installation?
We really, really don't. The most charitable of us manage to appreciate it as a quaint example of British discomfort, like those sinks with separate boiling/freezing water taps at opposite corners.
But I think something that people forget is that generally, fuses are there to protect wiring and fixtures (switches, connectors, etc) from fire. Preventing the device on the circuit that you, the user, cares about from completely melting down is just a nice bonus.
That's why building wiring codes generally spec fuses to cope with the capacity handled by wiring and switches, rather than the loads attached to it.
EDIT: In any case you NEVER want the car to silently and automatically try to "re-set" a tripped breaker, surely. You want this kind of fault to present itself noisily and obviously; it's a precursor to a potentially dangerous condition.
Any automatic re-set will have to factor in some cool-down time for the wiring in between attempts... what is the temperature of an overheating pair of conductors in the wiring loom when the breaker tripped? What rate of heat dissipation is there allowing them to cool down again? A wire which has experienced overheating will have a different (higher) resistance after the short-circuit event. Even if the wire isn't permenantly damaged, the temporary increase in temperature will still guarantee a momentarily higher resistance. Will the wire still have low enough resistance to trip the breaker again when the short is applied again?