Re:Outsmarting the smart meter
by tptacek on Saturday August 02, 2014 @08:18PM
(#8126553)
What smart meter brands (and in which models) actually support this protocol? I haven't seen it running anywhere. Is this more common outside the US?
[ Parent
| on HN ]
It's mainly used in Europe. The US has a very similar, but older protocol called ANSI C12. The C12.22 spec includes authenticated encryption, but I'm not familiar with the details.
C12.22 is DES-CBC with CRC-16 used as integrity checks. :)
Ouch, thats bad :) C12.22 is pretty old, AES didn't even exist yet. It seems that it got an update recently (2011) with the smart grid and smart metering use case in mind. The are now using an EAX called EAX prime [1] put it seems to have it's own issues [2].
[1] http://csrc.nist.gov/groups/ST/toolkit/BCM/documents/propose... [2] http://eprint.iacr.org/2012/018.pdf