News for hackers. Stuff that matters.
Re:Outsmarting the smart meter by flux_w42 on Saturday August 02, 2014 @07:12PM (#8126373)
There is a standard for smart meters called DLMS [1]. It's the most used protocol for smart meters for a while now. The protocol supports two way authentication and uses AES-GCM.

Providing a secure medium for meter communication is in the interest of both the user and the power companies: Users are protected from malicious commands to the meter (using the breaker to disconnect your power, changing the used tariff, ...) and power suppliers prevent fraud.

[1] http://www.dlms.com/

Re:Outsmarting the smart meter by tptacek on Saturday August 02, 2014 @08:18PM (#8126553)
What smart meter brands (and in which models) actually support this protocol? I haven't seen it running anywhere. Is this more common outside the US?
Re:Outsmarting the smart meter by flux_w42 on Sunday August 03, 2014 @07:14AM (#8127643)
It's mainly used in Europe. The US has a very similar, but older protocol called ANSI C12. The C12.22 spec includes authenticated encryption, but I'm not familiar with the details.
Re:Outsmarting the smart meter by tptacek on Sunday August 03, 2014 @11:20AM (#8128146)
C12.22 is DES-CBC with CRC-16 used as integrity checks. :)
Re:Outsmarting the smart meter by flux_w42 on Thursday August 07, 2014 @12:36PM (#8148648)
Ouch, thats bad :) C12.22 is pretty old, AES didn't even exist yet. It seems that it got an update recently (2011) with the smart grid and smart metering use case in mind. The are now using an EAX called EAX prime [1] put it seems to have it's own issues [2].

[1] http://csrc.nist.gov/groups/ST/toolkit/BCM/documents/propose... [2] http://eprint.iacr.org/2012/018.pdf