Re:OpenBSD will shut down if we do not have the funding to k...
by bashinator on Thursday January 16, 2014 @06:33PM
(#7073231)
I thought most (if not all) gigabit Ethernet implementations auto-detect host-to-host connections and handle the crossover for you.
Re:OpenBSD will shut down if we do not have the funding to k...
by reeses on Saturday January 18, 2014 @04:16AM
(#7080589)
They all do now, but it's still an optional element of the standard.
Re:OpenBSD will shut down if we do not have the funding to k...
by teddyh on Saturday January 18, 2014 @01:01PM
(#7081601)
It was optional in 100Mbit. In gigabit, it is mandatory.
Re:OpenBSD will shut down if we do not have the funding to k...
by reeses on Saturday January 18, 2014 @01:50PM
(#7081781)
"Automatic MDI/MDI-X Configuration is intended to eliminate the need for crossover cables between simi-lar devices. Implementation of an automatic MDI/MDI-X configuration is optional for 1000BASE-T devices. The assignment of pin-outs for a 1000BASE-T crossover function cable is shown in Table 40-12 in 40.8."
Here's a link that does not require IEEEXplore access: http://www.scribd.com/doc/46141801/802-3ab-1999
It reminded me of a post-it I left in the company lab with a diagram for how to do proper gigabit cross-overs. I could still find it there five years later after they rearranged the lab several times.