it wouldn't surprise me if a human gave off 600 watts of heat
Much closer to 100W sustained. I can hit 600-700W, very briefly, on a rowing machine. Wouldn't care to keep that up for more than a minute or two.
Re:Sears is Turning Shuttered Stores into Data Centers
by greenlander on Thursday May 23, 2013 @10:35PM
(#5760960)
I second the "100W sustained" number. I did the math once with the assumption: 2000 kilocalories/day diet, 4.1852J/calorie, 86400 seconds/day, all input calories are eventually given off as heat.
2000 * 1000 * 4.1852 / 86400 = 97 watts
Excellent point. I remember when I put an HVAC system in many years ago (in a plant) the calculation was something like 2000btu per person in heat generated in terms of sizing.
I was curious so I just checked (couldn't back then) to see if that figure is anywhere near correct but can't seem to find the answer.
This seems to indicate that 600 watts is about 2k btu per hour it wouldn't surprise me if a human gave off 600 watts of heat:
http://www.rapidtables.com/convert/power/Watt_to_BTU.htm
Actually this more or less shows it is ballpark:
http://answers.yahoo.com/question/index?qid=20081206141450AA...