Re:Webcam Pulse Detector by AdamTReineke on Tuesday April 16, 2013 @12:37AM (#5556274)
On each heartbeat, blood is pushed and makes the skin nearly unperceivably redder. By watching for and tracking this subtle change, you can extract a heartbeat.
Re:Webcam Pulse Detector by huhtenberg on Tuesday April 16, 2013 @06:09AM (#5557238)
> ... unperceivably redder

But why is he analyzing the green channel then? :)

Re:Webcam Pulse Detector by mkopinsky on Tuesday April 16, 2013 @11:58AM (#5558881)
Look at the absorption spectra at http://omlc.ogi.edu/spectra/hemoglobin/index.html. Green is ~510nm, red is ~650nm, blue is ~475nm. The difference between the absorption of Hb and HbO2 in the red range is the reason why pulse oximeters use red. In this case, we don't care about differentiating oxy- vs. deoxy-hemoglobin, we just care about the total absorption. Since more light is absorbed at green than at red, it will show more of an effect with pulse.

I am not confident in this explanation, and still don't know why green over blue.

Re:Webcam Pulse Detector by acuozzo on Tuesday April 16, 2013 @12:55PM (#5559276)
> I am not confident in this explanation, and still don't know why green over blue.

I'm not sure either, but I can tell you that if you examine digitized (RGB) 35mm film -- across all 35mm film stocks -- the blue channel is the most noisy.

So my guess is: He might have chosen green over blue due to the blue channel being noisier.

Re:Webcam Pulse Detector by mkopinsky on Tuesday April 16, 2013 @01:54PM (#5559658)
Is that noise inherent to film? Do webcams have the same noise?
Re:Webcam Pulse Detector by jerich on Tuesday April 16, 2013 @02:24PM (#5559857)
The green channel has the least noise for Bayer-sensor digital cameras (which is almost all of them).

50% of the sensor sites are green (25% each for red and blue), so there is more signal given the same amount of noise.

Re:Webcam Pulse Detector by mkopinsky on Tuesday April 16, 2013 @04:59PM (#5560861)
Why do they make them like that? Why not make the sensors 33/33/33?
Re:Webcam Pulse Detector by jerich on Tuesday April 16, 2013 @05:38PM (#5561074)
From Wikipedia on the Bayer Filter: "Bryce Bayer's patent (U.S. Patent No. 3,971,065) in 1976 called the green photosensors luminance-sensitive elements and the red and blue ones chrominance-sensitive elements. He used twice as many green elements as red or blue to mimic the physiology of the human eye. The luminance perception of the human retina uses M and L cone cells combined, during daylight vision, which are most sensitive to green light."

The Foveon sensor does sample RGB at every pixel by using 3 layers, but it is only used in a few cameras.