See also: https://plugsocketmuseum.nl/GB-foldingPlug1.html
My international travel "brick" for laptop + phone is an Anker PowerPort Atom III Slim, which is flat multi-port charger with an IEC-320-C8 input. For the Continent, I plug in a "0cm cable" that's a Europlug nub. For US and UK/I, a NEMA cord with a compact BS1363 "shaver adapter" with a 1A fuse in it. Really wish I could get something flatter to be the adapter! Maybe I'll have to make one.
I appreciate that they seem to put some effort into the design of their UK only products, instead of just shipping a US/Cn shaped charger with a BS1363 plug grafted on
I tried that once and the fit was so tight I thought I'd break both the plug and the outlet.
The look can be improved by using receding covers. I am sure they exist for Schuko outlets, here is one for a type E socket (CEE 7/5, usually compatible with Schuko AKA 7/3, using 7/7 plugs): https://www.domomat.com/53812-prise-de-courant-affleurante-o...
As a side note, the type E is polarized, though on occasion you can find modified 7/7 plugs that accept both orientations (I see this most commonly on PLC adapters). IEC 60906-1 was designed to replace Schuko but was not adopted.
Most people in the US will go their whole lives without having an issue related to this or knowing anyone who did. This is one of those problems that mostly only exists as a post-hoc justification for an already held belief.
Regardless, the typical outlet is not GFCI protected just due to the math of volume of new construction vs old construction vs service life. We're probably close to 50% coverage in new builds, more in low room count/wall area apartments. Tamper proof outlets are a better solution for this non-problem anyway.
> Yeah until you have kids. Before GFCI were a code requirement, electrical incidents were a constant source of injuries and fatalities.
Isn't GFCI only required in wet areas (e.g. kitchen and bathroom)? And even if they're not more widely required, code requirements aren't retroactive, so I'd imagine the vast majority of houses will be missing GFCI from a large number of outlets.
Austrian electrical code is even more strict, every time a renter changes or the home is sold, electrical wiring has to be brought fully up to current code.
I'd call both the British and the Schuko better. But they both come with tradeoffs. The British plug is huge, in part because of the built-in fuse. The Schuko is aesthetically less clean because the outlet is not flush, and because the plug is reversible you can't design around polarity. Both excellent plugs that are huge improvements over the US plug design in most ways, but both come with their own tradeoffs