Re:How multi-disk failures happen by CrLf on Tuesday January 01, 2013 @08:20AM (#4992543)
Maybe I was wrong in using the term "transient error"...

A bad block reallocation can be seen as a transient error from the controller's perspective, but it isn't silent provided the drive doesn't lie about it (and one would expect that a particular storage system vendor doesn't choose - and brand - drives that lie to their own controllers).

The storage system may ignore medium errors that force a repeated read (below a certain threshold), but they shouldn't ignore a medium error where the bad sector reallocation count increases afterwards (which is just another medium error threshold being hit, this time by the drive itself).

I'm not saying that higher-end drives are more reliable or not. Given that most standard SATA errors go undetected for longer, one could even argue that higher-end drives seem to fail much more frequently... I've had more FC drives replaced in a single EMC storage array than in the rest of the servers (which have a mix of internal 2.5in SAS and older 3.5in SCSI320 drives), and we certainly replace more drives in servers than desktops.

But that's another topic entirely.