Re:What California Is Learning from Solar Panels Built over ... by quickthrowman on Wednesday September 23, 2026 @04:32PM (#49822132)
Ah I see what you’re referring to.

I was taught that the safe way to keep using the old pre-8000 series wire is to use the specific listed fittings for this purpose (WAGO 221 series nuts are fit for purpose) with contact paste and a copper pigtail that connects to the device.

Re:What California Is Learning from Solar Panels Built over ... by trollbridge on Wednesday September 23, 2026 @11:20PM (#49825829)
I assume you mean 222, and Wago's have earned a reputation for working themselves loose after enough years rather randomly to the point some reputable electrician outfits here won't use them. I would not bother with pre-8000 wire at all in thinner gauges (10 and thinner).