There is basically zero truth about the water use propaganda. Liquid cooling is closed-cycle, just like in a car.
Re:Nashville uses eminent domain to block data center near zoo by wlesieutre on Wednesday August 05, 2026 @11:22PM (#49192037)
Having a closed coolant loop and using evaporative cooling which expends water aren't mutually exclusive. It's possible for a datacenter to manage heat rejection by blowing air over a radiator like a car does, but it's much easier and cheaper to cool by evaporating water.

This can be set up using a closed coolant loop that takes heat out of the servers, then cools back down the coolant by exchanging that heat into a second separate coolant stream. That way you don't need to care as much about the purity of the water you're drawing and evaporating for evaporative cooling, only the first sealed loop gets pumped though your server racks.

This is the type of setup they're talking about with the much discussed xAI datacenter in Memphis, where xAI pinky swears they are definitely going to resume construction on their wastewater treatment plant [1] and use that for cooling instead. It definitely is designed to consume water and evaporate it, not a closed system like a car radiator that puts its waste heat into ≠the air with no evaporation.

[1] https://wreg.com/news/local/xai-to-resume-construction-on-wa...

Re:Nashville uses eminent domain to block data center near zoo by bri3d on Wednesday August 05, 2026 @11:13PM (#49191976)
A sizable percentage of datacenters use open loop water spray towers, but the alternative, forced air exchange (ie add more giant fans) uses more electricity. It’s fairly complex to quantify which is “better” or “worse” but there exist data centers that evaporate a ton of water and send it elsewhere. (for what it’s worth I agree most of the anti datacenter hype is overblown and driven by specific poorly designed gas turbine powered installations).
Re:Nashville uses eminent domain to block data center near zoo by magicalist on Wednesday August 05, 2026 @11:31PM (#49192099)
> driven by specific poorly designed gas turbine powered installations

*increasingly nonspecific. See [1] for example

[1] https://floodlightnews.org/ai-data-centers-texas-pollution-l...

Re:Nashville uses eminent domain to block data center near zoo by nullpoint420 on Wednesday August 05, 2026 @11:10PM (#49191947)
I thought this too. Apparently there’s open cooling systems as well that are more efficient
Re:Nashville uses eminent domain to block data center near zoo by thedougd on Wednesday August 05, 2026 @11:15PM (#49191990)
Yes. Evaporative cooling towers. I suppose in those cases nearly all the water used goes to atmosphere.
Re:Nashville uses eminent domain to block data center near zoo by userbinator on Thursday August 06, 2026 @12:11AM (#49192327)
...which then comes down again as rain, and in those areas where it's dry enough that evaporative cooling works, the increased humidity might actually be a good thing.
Re:Nashville uses eminent domain to block data center near zoo by altcognito on Thursday August 06, 2026 @12:17AM (#49192363)
In areas it's dry enough it is just leaving that watershed. It will be carried hundreds and thousands of miles away.
Re:Nashville uses eminent domain to block data center near zoo by userbinator on Thursday August 06, 2026 @12:40AM (#49192523)
Decades ago, there was a plan to equalise the water supply throughout the country: https://en.wikipedia.org/wiki/North_American_Water_and_Power...

Now China is beating us: https://en.wikipedia.org/wiki/South–North_Water_Transfer_Pro...

Re:Nashville uses eminent domain to block data center near zoo by altcognito on Thursday August 06, 2026 @01:14AM (#49192744)
Oh good, I'm glad China is beating us in the path to stupidity. These types of projects are the dumbest things we ever did here. Classic!

Nothing dumber than reallocating resources thouands of miles away from where they should be.

Re:Nashville uses eminent domain to block data center near zoo by userbinator on Sunday August 09, 2026 @05:24AM (#49229824)
You seriously think that it's a good thing to have absolute drought in some areas, while others are experiencing intense flooding?
Re:Nashville uses eminent domain to block data center near zoo by uluyol on Wednesday August 05, 2026 @11:14PM (#49191979)
The water use comes from evaporative cooling, not liquid cooling.

Liquid cooling pulls heat away from the chips. Evaporative cooling takes it out of the building.

There are alternatives, but evaporative cooling is very energy efficient.

Re:Nashville uses eminent domain to block data center near zoo by isuckatcoding on Wednesday August 05, 2026 @11:12PM (#49191965)
Is this actually true?

Aren’t there real instances of metas data centers causing havoc for nearby residents? Light/boise pollution, contaminated water are real things