Re:Thirty Years of the Square Kilometre Array
by Etheryte on Wednesday January 28, 2026 @10:52AM
(#46796939)
This makes no sense though? Given the Nyquist theorem, simply increasing sampling frequency past a certain step doesn't change the outcome.
[ Parent
| on HN ]
Re:Thirty Years of the Square Kilometre Array
by labcomputer on Wednesday January 28, 2026 @01:24PM
(#46799496)
Actually, it does. You can decimate the higher sample rate to increase dynamic range and S/N ratio.
Also, for direct down conversion, you can get better mirror frequency rejection by oversampling and filtering in software.
Re:Thirty Years of the Square Kilometre Array
by Etheryte on Wednesday January 28, 2026 @04:59PM
(#46802151)
None of this changes the actual real amount of data you have at the end of the day though after all is said and done, that's what I mean, so long as you don't botch it and capture too little. In computing terms, the amount of real data in a compressed archive and the uncompressed original is the same, even if the file size is larger for the latter.
Re:Thirty Years of the Square Kilometre Array
by touisteur on Wednesday January 28, 2026 @07:04PM
(#46803648)
Sorry, not sure I follow from what I said (explaining how much data sensors produce) to 'increasing the sampling frequency' ? You're usually sampling at larger width to then put specifically taylored pass-band filter and removing aliasing effects and then downsampling. This is a classic signal acquisition pattern : https://dsp.stackexchange.com/questions/63359/obtain-i-q-com...