Re:NTP at NIST Boulder Has Lost Power by PunchyHamster on Saturday December 20, 2025 @07:39AM (#46335744)
technically if you have 3 or more sources that would be caught; NTP protocol was designed for that eventuality
Re:NTP at NIST Boulder Has Lost Power by da_chicken on Saturday December 20, 2025 @07:55AM (#46335822)
Sure, but not needing a failure to cascade to yet another failsafe is still a good idea. After all, all software has bugs, and all networks have configuration errors.
Re:NTP at NIST Boulder Has Lost Power by throw0101c on Saturday December 20, 2025 @09:54AM (#46336609)
> technically if you have 3 or more sources that would be caught; NTP protocol was designed for that eventuality

Either go with one clock in your NTPd/Chrony configuration, or ≥4.

Yes, if you have 3 they can triangulate, but if one goes offline now you have 2 with no tie-breaker. If you have (at least) 4 servers, then one can go away and triangulation / sanity-checking can still occur with the 3 remaining.

Re:NTP at NIST Boulder Has Lost Power by ufocia on Saturday December 20, 2025 @10:57AM (#46337055)
Your probably meant trilaterate.