Re:Hybrid AC/DC distribution system with a shared neutral (2... by Gibbon1 on Thursday May 01, 2025 @04:05PM (#43862739)
What the world needs is a 150 watt low voltage power over ethernet standard for lighting an low power appliances.
Re:Hybrid AC/DC distribution system with a shared neutral (2... by londons_explore on Thursday May 01, 2025 @04:26PM (#43862968)
USB-C fulfils that already.

It doesn't work out economically because big networks of usb devices (ie. Hubs) all need the power components if one is to maintain the generalisability of being able to plug anything into the grid anywhere.

Re:Hybrid AC/DC distribution system with a shared neutral (2... by kevin_thibedeau on Thursday May 01, 2025 @04:38PM (#43863086)
USB has significant length limitations and the cabling is generally not plenum rated. It's also silly to have a cable with wires that will never be used beyond negotiating for power.
Re:Hybrid AC/DC distribution system with a shared neutral (2... by deepsun on Thursday May 01, 2025 @05:25PM (#43863543)
USB-C is for short distances (<4m) and is more expensive than CAT6 cable.

https://www.cablematters.com/Blog/USB-C/how-long-can-a-usb-c...

Re:Hybrid AC/DC distribution system with a shared neutral (2... by holowoodman on Thursday May 01, 2025 @04:44PM (#43863136)
There is, shockingly enough, 100W PoE lighting...

https://www.cisco.com/c/en/us/solutions/enterprise-networks/...

Imho a totally crazy waste of expensive gear, but whatever floats your boat...

Re:Hybrid AC/DC distribution system with a shared neutral (2... by NewJazz on Friday May 02, 2025 @12:22AM (#43866166)
Isn't it cheaper and more reliable than a dozen ZigBee bulbs?
Re:Hybrid AC/DC distribution system with a shared neutral (2... by holowoodman on Friday May 02, 2025 @03:57AM (#43867261)
Could be, I don't have any price info on all of the PoE lighting stuff.

But let's say i've got an office area, where I would need 2kW lights in total (which isn't much, I think 200W per desk is considered bright enough). This would need 20 PoE ports, 20 cables, 20 PoE-capable light fixtures with the right transformers/bulbs. Just the 2kW/>20port PoE-Switch will set you back 2k€ or more, no idea what the light fixtures will cost. Maybe a 50W ZigBee bulb will cost 50€, you need 20, then you are at the price of just the switch. And you can just use plain electrical wiring, no need to do the whole more expensive Cat6+Patchpanel thing.

And my personal favourite, even better than overly expensive ZigBee bulbs: https://www.shelly.com/de/products/shelly-dimmer2 Wifi-controllable dimmer, speaks MQTT or HTTP, for a load of 200W at 35€, works with any dimmable light fixture. Also available as a relay if you aren't interested in dimming, then you can do 2kW in 2 channels at a lower price. And if you are worried about WiFi, there is a cabled version as well.

Re:Hybrid AC/DC distribution system with a shared neutral (2... by horsawlarway on Friday May 02, 2025 @07:36AM (#43868444)
200W is a huge number for modern lights.

You don't care about the power consumption, You care about the light level produced (Watts != Lumen).

Most advice says 500 to 1000 lux is fine for an office desk (en 12464).

For a 1 sq meter desk, that's about 800 lumens worth of light, or maybe 50 watts max in modern LED lighting (two 800 lumen bulbs, 14W each).

LEDs are just way better than older lights.

Re:Hybrid AC/DC distribution system with a shared neutral (2... by NewJazz on Sunday May 04, 2025 @05:43PM (#43889831)
I'm sitting staring at an 8W filament led Edison bulb, 800 lumens. For a zigbee bulb I found, 11W, 1100 lumens. And I think they include ZigBee overhead in their 11W? Don't even need PoE+ for that.

It would just come down to chip and maybe power cost difference between Ethernet with PoE vs wireless with traditional 120V electrical wiring. Pretty pointless to retrofit I'd think, but for new construction it could be viable.

Re:Hybrid AC/DC distribution system with a shared neutral (2... by NewJazz on Sunday May 04, 2025 @05:49PM (#43889876)
Saw a 24 port Juniper PoE+ switch for around $450. EX3300-24P. And a 48 port variant. Only 400 and 700 Watt output respectively. But that is enough for ~15W per fixture, which should get well above 1000 lumens.

I'll admit that at a certain point it is a lot of switches to manage.

Re:Hybrid AC/DC distribution system with a shared neutral (2... by SigmundA on Thursday May 01, 2025 @04:48PM (#43863175)
POE+++ is 90W so maybe POE++++?

Hard to go up in voltage as its now no longer considered "low" voltage wiring and hard to go up in current without increasing conductor size of ethernet cable.

Re:Hybrid AC/DC distribution system with a shared neutral (2... by allenrb on Thursday May 01, 2025 @05:52PM (#43863791)
POE+=4 is a clear win at this level. ;-)
Re:Hybrid AC/DC distribution system with a shared neutral (2... by bill3478 on Thursday May 01, 2025 @05:55PM (#43863835)
Wouldn't that be POE+=2?

Also, if this is anything like USB it will be PoE 3.14 Gen 2 type E.

Re:Hybrid AC/DC distribution system with a shared neutral (2... by kbaker on Thursday May 01, 2025 @05:19PM (#43863491)
I could hope for a future PoE-over-Data Line (PoDL) version using an 18 AWG twisted pair that would work for this, providing something like 48V @ 3 or 4 A, and 10BASE-T1L for data. Hopefully a standard way to do this gains traction.

The existing limitation is with the 2x23 AWG (or 4x23 AWG) of Cat5e/6/6a not providing a lot of current-carrying capability at a safe voltage.

Re:Hybrid AC/DC distribution system with a shared neutral (2... by grumpy-de-sre on Friday May 02, 2025 @02:59AM (#43866954)
Big concern IMO with 10BASE-T1 and PoDL for long runs / in wall installations etc is the lack of galvanic isolation. Maybe I'm just paranoid but there's a ton of advantages to not having to worry about things like ground loops and common mode voltages etc.

What I wouldn't mind would be a beefier 100BASE-TX 2-pair cable spec, and some extended PoE profiles. You'd need high current magnetics or something but surely that's possible.

Re:Hybrid AC/DC distribution system with a shared neutral (2... by deepsun on Thursday May 01, 2025 @05:30PM (#43863582)
Was just thinking about it for my home. Googling showed that it's only for commercial applications now (like "request a quote" for a lightbulb).

There is a good opportunity for a startup IMHO.

With 100W PoE, one can daisy-chain 10 light bulbs on one cable (or put them on different pairs of wires within one cat6 cable).

But what I really wanted is controllable devices, so that I could re-assign lights<->switches in my home hub.

UPDATE: and you don't need an electrician license to work with low voltage.

Re:Hybrid AC/DC distribution system with a shared neutral (2... by somat on Thursday May 01, 2025 @06:56PM (#43864281)
A managed switch will allow you to power on/off specific ports.

When I was looking at home automation systems and all the insanity found there. at one point I said "if I were to design a home automation system from scratch what would it look like?" my answer for the physical layer was poe and managed switches.

Re:Hybrid AC/DC distribution system with a shared neutral (2... by baby_souffle on Thursday May 01, 2025 @07:03PM (#43864334)
> A managed switch will allow you to power on/off specific ports.

As somebody that's looked into this... yes, but. The contemporary light switch is instant. Within a few nanoseconds of your brain feeling the "click", you see the light. There's a noticeable latency from an API request to the switch's control plane which then talks to the power control which then turns power to the port off and then the light goes out. You have the additional delay of poe negotiation for the "turn on" operation, too.

Re:Hybrid AC/DC distribution system with a shared neutral (2... by somat on Thursday May 01, 2025 @07:12PM (#43864405)
That is how I managed to talk myself out of investing in a home automation setup, none of the incompatible systems felt good and more importantly, they were all worse than having a physical switch I can toggle.
Re:Hybrid AC/DC distribution system with a shared neutral (2... by doubleg72 on Thursday May 01, 2025 @09:13PM (#43865183)
Lutron offers a variety of styles that work near instantly. I’ve been using them for years.
Re:Hybrid AC/DC distribution system with a shared neutral (2... by lazide on Friday May 02, 2025 @10:38AM (#43870420)
It really isn’t- 20-30ms minimum for most switches/lights, on average. Incandescent likely a bit more.

Which is still ‘instant’, but with some non-ridiculous implementation, also easy to do with a ‘smart home’.

Of course most implementations are pretty ridiculous, so there does that idea.

Re:Hybrid AC/DC distribution system with a shared neutral (2... by monster_truck on Thursday May 01, 2025 @10:03PM (#43865427)
You would likely need a low voltage license to permanently install something like this in most states. There are standardized limits on how many of these can be run in parallel due to heat constraints which is one of the thresholds that necessitates a license
Re:Hybrid AC/DC distribution system with a shared neutral (2... by ARob109 on Thursday May 01, 2025 @11:03PM (#43865782)
I keep telling myself one day I’ll design a PoE DC to 120VAC adapter board so I can run PoE to a standard outlet box or light switch.
Re:Hybrid AC/DC distribution system with a shared neutral (2... by Gibbon1 on Friday May 02, 2025 @03:25AM (#43867095)
Yeah you get it. What triggered it for me is there is a PoE standard for automotive that can deliver 50W over a single twisted pair.

If you bumped that to 125 to 150W then it would yes be great for residential for all the reasons you can think of.

Cheap cable, crimp connectors. No license required to install.

Low voltage and generally much safer than 120V and especially 240V. Consider with power negotiation a default max power of a few watts which isn't going to start fires.

Wanna replace a light fixture? Unscrew the old one, unplug it. Plug the new one in and screw it back on.

Also imagine kid safe outlets that are standard world wide.

Re:Hybrid AC/DC distribution system with a shared neutral (2... by zdragnar on Thursday May 01, 2025 @06:06PM (#43863919)
As an American, I'd just be happy if we switched to 240v rather than 120.
Re:Hybrid AC/DC distribution system with a shared neutral (2... by somat on Thursday May 01, 2025 @07:08PM (#43864379)
three phase, If we are going with unrealistic dreams, I want three phase to every house.

"avoids eye contact as you patently explain that the only real benefit to three phase is for motors"

But really the US is a 240V system. we just split the phase and wire the house in two halfs. you should not even need to rewire your house. Just hook the neutral to the opposite phase in the panel, like magic you now have 240V in every outlet.

Don't actually do this it will end up killing someone.

Re:Hybrid AC/DC distribution system with a shared neutral (2... by xenadu02 on Thursday May 01, 2025 @07:49PM (#43864674)
As the sibling comment notes: The US/Canada are already split-phase 240v/120v systems.

As near to 100% as makes no difference every single house is already wired for 240v. In fact wired for it and using it: electric ranges, stoves, dryers, etc are all 240v.

NEMA even defines 240v receptacles/plugs for normal amperage: NEMA 6-15 (two horizontal blades: meh face) and 6-20 (one vertical, one horizontal: wink with other eye closed). Unlike the common 240v dryer/large appliance cords that are huge and bulky 6-15 and 6-20 are about the same size as our current 120v plugs. They have the same compatibility as 5-15/5-20: The 15 amp version fits in the 20 amp receptacle but the 20 amp only fits 20 amp. And it is impossible to plug 120 into 240 or vice-versa. Everything made for 120v (to a rough approximation) is also rated for 240v.

Unfortunately no one bothers to install the 6-15/6-20 plugs. There is nothing stopping any builder from doing it standard, especially in the kitchen. There is nothing stopping a homeowner/buyer from asking for it either. But no one does. Therefore there is no market for appliances that use these plugs. And thus no demand to wire for them.

It would likely take a push from government, manufacturers, the NEC, etc to push for supporting 240v for common appliances. Start installing them in new homes. Offering the 240v version of electric kettles and such.

Note: some European appliances can be wired up this way and will run fine because they tolerate 60Hz but not all of them.

Re:Hybrid AC/DC distribution system with a shared neutral (2... by zdragnar on Thursday May 01, 2025 @09:05PM (#43865147)
Eh, if we're going to be making big changes, might as well switch to the type C and type E plugs / sockets as well. They're safer, and the distinguishable nature from the type A / 120v devices currently in use (esp the ones that really can't handle 240).
Re:Hybrid AC/DC distribution system with a shared neutral (2... by xenadu02 on Wednesday May 07, 2025 @06:31PM (#43921166)
We already have plug standards here and they are good enough. Sure they're objectively worse but in practice the cases where it ever mattered are a rounding error. Better to encourage adoption of parts of our own existing standard then propose a wholesale change.
Re:Hybrid AC/DC distribution system with a shared neutral (2... by mauvehaus on Thursday May 01, 2025 @09:10PM (#43865166)
NEMA 6-15 and 6-20 seem to be pretty uncommon. This is no doubt in part because most stuff we run on 240 in the US is higher amperage anyway, and probably in part because some stuff also wants a neutral?

The only NEMA 6 I have is on my table saw, and maybe the planer? Everything else is NEMA 14 (two hots, neutral, and ground). The upside of that is the bulb in your dryer, for example, can be a standard 120 volt bulb.

I'd also like to note that the locking connectors plug and unplug a hell of a lot nicer than the non-locking ones, at least at the 30 amp size (which is common for a dryer). They just operate much more smoothly, presumably because they aren't relying on friction to keep them plugged in.

Re:Hybrid AC/DC distribution system with a shared neutral (2... by xenadu02 on Wednesday May 07, 2025 @06:45PM (#43921281)
> This is no doubt in part because most stuff we run on 240 in the US is higher amperage anyway,

You've got the cause/effect backwards I think. The high amp stuff needs 240v to avoid ridiculous amp requirements. The lower power stuff just defaults to 120 because that's the most compatible leading to the chicken-and-egg problem.

> probably in part because some stuff also wants a neutral?

I've tried to come up with reasons this might matter but so far I can't. The Neutral (or really L2 in this scenario) is the reference plane. It moves in step with L1 and so when L2 is high (+120) L1 is low (-120), but from the POV of the reference that's just -240. Same for the other cycle half.

In other words measuring voltage is relative in all cases. Unless you are measuring in relationship to the earth (an infinite sink for our purposes) you can't tell if you are seeing +120/-120 or +240/0.

Perhaps there is something that relies directly on the voltage potential between Line and Ground, I just don't know of any. Most things that are sensitive to an actual ground reference are electronics which run on DC and are separated from the mains by their power supply anyway.

Re:Hybrid AC/DC distribution system with a shared neutral (2... by repiret on Thursday May 01, 2025 @11:21PM (#43865878)
> Unfortunately no one bothers to install the 6-15/6-20 plugs

Almost no one, but I had a 6-15R put in my kitchen. Then I imported a 3kW tea kettle from the UK, lopped off the plug, and put on a 6-15P. And now my wife doesn’t have to wait very long for her hot water.

Re:Hybrid AC/DC distribution system with a shared neutral (2... by neither_color on Friday May 02, 2025 @10:55AM (#43870660)
This is a common misconception. You do have 240V(or 208V in some apartments if we're being pedantic). You primarily use it in the kitchen(range receptacle), laundry, and for your HVAC equipment or an EV charger if you have one.

Someone who knows what they're doing can also add a 240V outlet to any room.

We don't serve 120V to homes, we take 240V and split it. In fact, that's not the only time you use a mix of different voltages. You take that 120V, and then further transform it to 18-24V for things like doorbells and thermostats, or you use a power-brick at the wall to convert it to direct current to charge your laptop, phone, and other items. In none of those use cases would 240V really change your life. It's really only better at boiling water in counter-top kettles. I'm guessing we don't use more 240V kettles because we're not a tea drinking country and culturally people tend to use coffee machines that are "fast enough", but not slow enough to be worth switching over.

Re:Hybrid AC/DC distribution system with a shared neutral (2... by deepsun on Friday May 02, 2025 @03:26PM (#43873765)
> We don't serve 120V to homes, we take 240V and split it.

Ackchyually, we deliver 120V to the poles, not 240V. Then transformers at the poles near the homes split it to two 120V phases, 180° apart. So the difference between +120V and -120V becomes 240V. But the pole wires are still 120V.

Re:Hybrid AC/DC distribution system with a shared neutral (2... by mystified5016 on Friday May 02, 2025 @10:43AM (#43870504)
PoE seems excessively wasteful for dumb loads. 8 conductors for lighting and a dozen bytes of "turn off bulb 1234" is crazy. Not to mention that you need almost as much electronics on either end of the wire as you do with any 120VAC to DC adapter.

We definitely need domestic DC systems, but not loaded down with the hardware and software complexity of Ethernet. You could run three wires for DC plus half-duplex RS232 or similar, or you could do two wires and impose a high frequency communication signal on top of the DC. There are many options that don't require your lights to have IP addresses.

Re:Hybrid AC/DC distribution system with a shared neutral (2... by deepsun on Friday May 02, 2025 @12:01PM (#43871539)
Even though it's 8 conductors, you still put only one cable, that's much easier than even two wires.

Low voltage means you don't need an electrician license to DIY, because it's not going to burn the house.

Mass producing cables and electronics becomes cheap. The limiting factor is then materials, not complexity. Look at ESP32 controllers for $7.

Also, I d like my cable to serve 10 light bulbs, each of which may not only turn on/off, but change brightness and color temperature.